
S9240F1004 MODULATING HOT SURFACE IGNITION INTEGRATED FURNACE CONTROL
19
69-2088—01
Fig. 9. S9240F sequence on Light Off and Call for 1st Stage Heat cycle (2-stage thermostat).
1. Light Off and Call for 1st Stage Heat (2-Stage Thermostat)
M28154
Call For 2nd Stage Heat
Call For Heat Satisfied
Limit
Switch
Closed?
Circulator OFF After
Heat Fan OFF Delay
(High Heat Speed)
Limit
Closes Within 3
Minutes?
NO
Soft Lockout:
Error Code
Flashes
flashes
YES
Inducer ON
(Max Speed)
Rollout
Circuit
Closed?
Low
Pressure
Switch
Open?
Low
Pressure Switch
Closed Within 150
Seconds?
High
Pressure
Switch
Open?
YES
NO
NO
NO
NO
YES
NO
Circulator ON
(Max Speed)
Inducer ON
(Max speed)
Circulator ON
(Mid Speed)
De-Energize
Gas Valve
De-Energize
Gas Valve
Error Code
Flashes
Error Code
Flashes
Rollout
Circuit
Closes?
Inducer OFF
After Post-Purge
Circulator OFF After
Heat Fan OFF Delay
Hard Lockout:
Error Code
Flashes
Error Code Flashes
After 5 Seconds
Error Code Flashes
After 5 Seconds
L
I
G
H
T
O
F
F
Safety
Check
Circulator OFF After
Heat Fan OFF Delay
(Low Heat Speed)
Verify There
Is No Main Burner
Flame
YES
YES
Low Pressure
Switch Opens
High Pressure
Switch Opens
YES
Inducer ON
at Ignition
Firing Rate Speed
NO
Pressure Switch
Calibration
Pre-Purge
15 Seconds
YES
H.S.I. ON
20 Seconds
Gas Valve
Energized
Ignition Trial Begins
(H.S.I. ON)
Heat Fan On Delay
Timer Started
Flame
Sensed Within
4 seconds?
H.S.I. OFF
Gas Valve
De-energized
H.S.I. OFF
Interpurge
(15 Seconds)
5th
Unsuccessful
Trial?
Wait For Ignition
Stabilization Delay
Post-Purge
(20Seconds)
Inducer OFF
Soft Lockout:
Error Code
Flashes
YES
NO
NO
YES
Call For
Heat
Ends?
NO
Circulator OFF After
Heat Fan OFF Delay
YES
Circulator
On?
YES
NO
C
A
L
L
F
O
R
1
S
T
S
T
A
G
E
H
E
A
T
3A
2
1
1
– OR –
Call
For
Heat?
NO
4
Calibrations
Attempted?
Calibration
Successful?
Wait
5 minutes
NO
NO
Soft Lockout:
Error Code
Flashes
YES
YES
YES
2
1
1
2
Set Target Firing Rate
Based on Thermostat
Signals Present
SOFT LOCKOUT IS RESET AUTOMATICALLY AFTER ONE HOUR WITH A CALL FOR HEAT ACTIVE,
OR BY CYCLING THE CALL FOR HEAT, OR BY CYCLING POWER TO THE CONTROL.
HARD LOCKOUT IS RESET BY CYCLING POWER TO THE CONTROL.
1
2