Q4000 Installation manual 

 
 

 Precautions on installation - Meter 

 

 

When installing the meter outdoors, provide shade to prevent 
exposure to direct sunlight

.

 

 

 

Do not mount the meter with its display surface facing 
downwards. 

 

 

Avoid installing the meter in a very high temperature 
environment as this will shorten the battery life. 

 

 

Provide clearance around the meter pipe section for piping 
work. Provide clearance (30cm or more between pipe edge 
and floor) for turning a box wrench, particularly under a 
meter pipe section which has lower side bolts and nuts that 
are difficult to tighten. 

 
 
 
 
 

Installation 

1.  Insert the studding in the lower two bolts and fix the bolts to 

the flanges. 

 
 
 

 

2.  Place the electromagnetic meter on the studs and set it in 

the desired position, taking care not to subject it 

 
 
 

3.  Insert the remaining studs and slightly tighten all bolts. Make 

sure that the meter pipe centre is not displaced and the 
display is not askew. Fit the gaskets in between the pipe 
ends and the meter.. 

 
 

4.  After you check the displacement of the meter pipe centre, 

tighten the nuts diagonally in the order shown by the arrows in 
the figure above. Tighten the nuts to squeeze the gaskets until 
fully sealed. 

 
 
 

 
 
Caution 

 

Make sure not to step on the display unit of the electromagnetic meter while you are 
doing the pipework.  

 

Never try to adjust the meter position using the display unit for grip after tightening the 
bolts.  

 

Do not attempt to correct problems by hitting the meter body. 

 

 

 

 
 

 