www.honeywell.com

PW-6000 Installation

Setting Up the PW-6000 Hardware

3.2  Setting the DIP Switches

Dual In-line Package (DIP) switches are read when the system powers up, except 
where noted otherwise. The following table shows the setting options.

Table 2  PW-6000 DIP Switch Settings

S1

S2

S3

S4

Selection

OFF

OFF

OFF

OFF

Normal Operating Mode.

ON

OFF

OFF

OFF

When DIP switch 1 is ON, Port 0 
communicates with the web browser. 
Port 1 is used for RS-232/485 
communications. After the panel 
initialization, enable the default user 
name (admin) and password (password). 
The user name and password are read 
dynamically; you do not need to reboot 
the panel.

OFF

ON

OFF

OFF

Use the factory default communication 
parameters.

ON

ON

OFF

OFF

Unless the network administrator 
reserves an IP address for the panel 
(based on the controller board’s Media 
Access Control (MAC) address), the 
PW-6000 uses Dynamic Host 
Configuration Protocol (DHCP) to 
obtain an IP address from the network 
DHCP server. 
When power is applied with the 
switches in this position, there is a ten 
second window (when LEDs 1and 2 
flash alternately with LEDs 3 and 4), 
during which memory is cleared if 
switch 1 or switch 2 is changed to OFF. 
When switch 1 or 2 is changed to OFF, 
only LED 2 flashes and memory begins 
to be cleared. This period of clearing 
lasts several minutes. When the memory 
has been cleared, the LED pattern 
changes to the flashing of LEDs 1 and 4. 
The panel then reboots by itself. All data 
in memory is erased except the serial 
number, MAC address, hardware 
revision, and OEM code.

Содержание PW-6000

Страница 1: ...August 2013 2013 Honeywell All rights reserved 800 00005V3 PW 6000 PW6K1IC Intelligent Controller and System Installation and Configuration Guide ...

Страница 2: ...States of America Honeywell reserves the right to change any information in this document at any time without prior notice Pro Watch is a trademark of Honeywell Inc Ordering Information Please contact your local Honeywell representative or visit us on the web at www honeywellintegrated com for information about ordering Feedback Honeywell appreciates your comments about this manual Please visit us...

Страница 3: ...and maintenance 8 2 Product Overview 8 2 1 PW 6000 and PW 5000 9 2 2 Port Settings 9 2 3 Other 9 3 Setting Up the PW 6000 Hardware 11 3 1 Setting the Jumpers 11 3 2 Setting the DIP Switches 12 3 3 Technical Specifications 14 3 4 Status LEDs 15 3 5 Supplying Power to the PW 6000 Interface 16 3 6 Communications Wiring 17 3 7 Cabinet Tamper and Power Failure Input Wiring 17 3 8 Memory and Real Time C...

Страница 4: ...2 www honeywell com 4 8 Restore Default Screen 27 4 9 Apply Setting Screen 28 4 10 Log Out 28 Appendix A PW 6000 Web Server and Pro Watch Channels Appendix B SNET Reader Settings ...

Страница 5: ...W6K1IC Installation and Configuration Guide Document 800 00005V3 1 In this chapter Notices 2 Product Overview 8 Setting Up the PW 6000 Hardware 11 System Configuration via Web Interface 18 1 PW 6000 Installation ...

Страница 6: ...on is not observed 1 1 2 Fire Safety and Liability Notice Not Evaluated by UL for fire life safety or burglary application Warning Never connect card readers to any critical entry exit door barrier elevator or gate without providing an alternative exit in accordance with all the fire and life safety codes pertinent to the installation AVERTISSEMENT Ne jamais connecter de lecteur de carte en un poi...

Страница 7: ... ULC compliance Only UL ULC Listed readers with standard Wiegand data output communication format protocol have been evaluated for use with this system This product is intended to be installed indoors within the protected premises Access Control System Model PW6000 and Controller Model PW6K1IC meet the requirements for CAN ULC S319 05 Equipment Class 1 This product s compliance to ULC S319 Electro...

Страница 8: ...amage During Shipment Caution IF ANY DAMAGE TO THE SHIPMENT IS NOTICED A CLAIM MUST BE FILED WITH THE COMMERCIAL CARRIER RESPONSIBLE FOR THE DAMAGE ATTENTION SI L EQUIPEMENT A SUBI DES DOMMAGES LORS DE SON TRANSPORT ADRESSER UNE RECLAMATION AU TRANSPORTEUR RESPONSABLE 1 4 Electro Static Discharge Caution Electro static discharge ESD can damage CMOS integrated circuits and modules To prevent damage...

Страница 9: ...st a copy from Honeywell Integrated Security Inc http www honeywellintegrated com index html and review the agreement carefully 1 5 Disclaimer Product Liability Mutual Indemnification If a Customer receives a claim that a Product or any component thereof has caused personal injury or damage to the property of others Customer shall immediately notify Honeywell Integrated Security in writing of all ...

Страница 10: ...refully pack the equipment for shipment Use the original packing material whenever possible 1 8 Limited Warranty All Products sold or licensed by Honeywell Integrated Security include a warranty registration card which must be completed and returned to Honeywell Integrated Security by or on behalf of the end user for Honeywell Integrated Security to provide warranty service repair credit or exchan...

Страница 11: ...rmation as confidential Customer shall acquire no rights in the design of the Products or the related materials except to use such information solely for the purpose of and only during the time it sells the Products Customer shall not copy the design of any of the Products or use or cause to be used any Product design or related materials for its own benefit or for the benefit of any other party T...

Страница 12: ...the PW 6000 and provides the real time processing for the connected I O interfaces The PW 6000 is designed to operate without the need for a PC It can be connected to a Pro Watch host computer using direct serial communication dial up modem or TCP IP network connection The PW 6000 holds the database for the subsystem configuration and card holders and the event log buffer which is in battery backe...

Страница 13: ... following table See Table 1 PW 6000 Jumper Settings on page 11 for more information on how to configure the port settings 2 3 Other An on board real time clock maintains the date and time taking into account leap year and accounting for global time zones and daylight savings time changes The database for the system configuration and card holders are stored in FLASH memory The event log buffer is ...

Страница 14: ...10 www honeywell com PW 6000 Installation Product Overview Figure 1 PW 6000 Connections LEDs and DIP Switches ...

Страница 15: ... as required 3 1 Setting the Jumpers Table 1 PW 6000 Jumper Settings Jumpers Set At Description J1 N A 10Base T 100Base TX Ethernet Connection Port 0 J2 N A Factory Use Only J3 OFF Port 2 RS 485 EOL Terminator is OFF ON Port 2 RS 485 EOL Terminator is ON J4 OFF Port 3 RS 485 EOL Terminator is OFF ON Port 3 RS 485 EOL Terminator is ON J5 OFF Port 1 RS 485 EOL Terminator is OFF ON Port 1 RS 485 EOL ...

Страница 16: ...factory default communication parameters ON ON OFF OFF Unless the network administrator reserves an IP address for the panel based on the controller board s Media Access Control MAC address the PW 6000 uses Dynamic Host Configuration Protocol DHCP to obtain an IP address from the network DHCP server When power is applied with the switches in this position there is a ten second window when LEDs 1an...

Страница 17: ...o set the IP address 3 Change the S4 S3 S2 S1 combination to off off off on DIP switch 1 is read on the fly This sets the login to the default user ID admin and password password for Ethernet communications 4 Create users See User Configuration on page 26 for instructions 5 Set the S4 S3 S2 S1 combination to off off off off 6 Configure the host port for TCP IP and or Serial communications See Host...

Страница 18: ...ps async An optional Lantronix CoBox Micro interface daughter board is supported 10Base T 100Base TX Not Evaluated by UL ULC Port 2 3 2 wire RS 485 2 400 to 38 400 bps async Inputs 2 non supervised dedicated for cabinet tamper and power fault monitoring Cable requirements Power 1 twisted pair 18 AWG RS 485 24AWG 4 000ft 1 200m maximum twisted pair with shield 120 ohm RS 232 24AWG 25ft 7 6m maximum...

Страница 19: ...6000 uses six on board LEDs to provide status information during its initialization sequence and normal run time operation 3 4 1 Initialization Table 4 PW 6000 Status LED Combinations During Initialization LED 1 LED 2 LED 3 LED 4 LED 5 LED 6 Description ON OFF OFF OFF OFF OFF Basic processor initialization ON ON OFF OFF OFF OFF Internal SRAM test ON OFF ON OFF OFF OFF External SDRAM First Chip ON ...

Страница 20: ...6000 Power Terminals Table 5 PW 6000 Status LED Combinations During Run Time LED Description 1 Off Line On Line and Battery Status Off Line 20 On ON Line 80 On Double Flash means the Battery is Low 2 Primary Host Communication Activity Ethernet or Port 1 3 Port 2 Communication Activity 4 Port 3 Communication Activity 5 ON Writing to Flash Memory Do NOT cut off power when this LED is ON 6 TBD SPD O...

Страница 21: ...gle bus of up to 4 000 feet 1 200 meters Use shielded twisted pair minimum 24 AWG with 120 ohm impedance Install termination jumpers only at the end of line unit Figure 3 PW 6000 Port Wiring 3 7 Cabinet Tamper and Power Failure Input Wiring Figure 4 PW 6000 TMP and FLT Terminals Inputs TMP and FLT are used for monitoring cabinet tamper and power failure with normally closed contacts These two inpu...

Страница 22: ... settings Notes If you are using Internet Explorer Enhanced Security Configuration you cannot access the ACDSM web server All pages will display Bad Request You must uninstall the Enhanced Security option before you can access the ACDSM The default factory set TCP IP address for the built in system configuration web server is 192 168 0 251 4 1 Connecting to ACDSM for the First Time 1 Use the facto...

Страница 23: ...ogin link to display the User Name and Password fields Figure 5 PW 6000 Web Server Login Screen 2 Enter your User Name and Password Note Default User ID is admin and the default Password is password 4 3 Home Page The first screen after the login is the home page which displays all the available configuration links on the left navigation bar Figure 6 PW 6000 Web Server Home Page ...

Страница 24: ...ption button and reserve an IP address for the MAC address or they can select the other option button and assign a Static IP address as well 4 4 1 Dynamic IP Configuration Method 1 Click the Dynamic IP option button to select the Dynamic Host Configuration Protocol DHCP method to obtain IP address automatically 2 Click OK Note The Pro Watch communicates with the PW 6000 panel using an IP address I...

Страница 25: ... in the appropriate fields IP Address Subnet Mask Default Gateway 2 Click OK 4 5 Host Port Click the Host Port link on the navigation bar to display the Host Connection Configuration screen where you can select the appropriate settings for the Primary Host Port and Alternate Host Port Note Some of the fields change dynamically depending on the Connection Type selected 4 5 1 IP Server Connection Ty...

Страница 26: ...dware Configuration in the Pro Watch Guide for channel encryption instructions c Port Number Enter the port number through which the host computer can communicate with the PW 6000 board d Select either Allow All or the Authorized IP Address Required option button Allow All as the label suggests allows all IP addresses to communicate with the PW 6000 Select this option for web page browser access I...

Страница 27: ...ce PW 6000 PW6K1IC Installation and Configuration Guide Document 800 00005V3 23 4 5 2 IP Client Connection Type Figure 9 PW 6000 Host Port Configuration Screen with IP Client Connection Note The PW 6000 panel does not currently support an IP Client connection ...

Страница 28: ... addresses for the PW 6000 board Note In the previous panels this selection was made through setting the virtual DIP switches 2 For the Primary Host Port make the following selections a Connection Type From the drop down list select Serial RS232 Select one of the following as appropriate Serial RS232 Serial RS495 Serial Modem Serial CoBox b Data Security Select one of the following values from the...

Страница 29: ...for the primary host port select IP Server from the drop down list for the alternate host port b Data Security Select one of the following values from the drop down list None Password no AES Password AES c Select a Baud Rate from the drop down list d Select a Flow Control from the drop down list 4 Click OK 4 6 Device Information Click the Device Info link on the navigation bar to display the read ...

Страница 30: ...dding a User Follow these steps 1 Click New Account to display the new user account screen 2 Enter the following User name a unique character string that identifies the user Level level of privileges the user will have Level 1 grants the user read write privileges to all panel features level 2 grants the user read only privileges to the Notes Network Host Port and Device Info features level 3 gran...

Страница 31: ...interval from the drop down list and click Save Auto Save Timer to save the setting 4 7 2 Editing a User To edit a user record click to select the user from the Username column and then click Edit Use the information provided in the previous section Adding a User to edit the record 4 7 3 Deleting a User To delete a user record click to select the user from the Username column and then click Delete...

Страница 32: ...Click the Apply Setting link on the navigation bar to apply the selected configuration values Figure 14 PW 6000 Web Server Apply Setting Screen Click Apply Reboot to apply all the configured values and reboot the PW 6000 4 10 Log Out Click the Log Out link on the navigation bar to log out of the web server ...

Страница 33: ...the pins as follows pin1 TR pin2 TR pin5 GND to RS 485 terminals of the Intelligent Auto Converter PW5K1CVT1 i e PW 5000 RS 232 RS 485 converter c Connect the RS 232 terminal of the PW5K1CVT1 converter to the serial port of your Pro Watch application server 2 Set the host port configuration of the PW 6000 web server a Login to the Access Control Device Server Configuration Manager b Set the Primar...

Страница 34: ...hannel and select Properties to display the Edit Channel Screen dialog box This screen displays configuration fields for the Primary Port related to the Primary Host on the web server as well as the Secondary Port related to the Alternate Host Port on the web server f For both Primary and Secondary ports select the appropriate values for the following configuration fields If the Port Type is Hard ...

Страница 35: ...3 31 In this appendix DKR Reader without Keypad 34 DKR Reader with Keypad 34 MSR Reader without Keypad 35 MSR Reader with Keypad 35 SNET Reader from PW 6000 IC 36 SNET Reader from PW 6000 2 Reader Board 37 PW6KIC vs Star Panel SNET Reader Behavior 39 B SNET Reader Settings ...

Страница 36: ...template is that the configured settings are applied each time that a new logical device is created so it saves time when these are configured with the settings that you want to use To configure the settings in the hardware template 1 Go to Hardware Configuration 2 Select Hardware Templates 3 Double click the appropriate template 4 Select the tab Device Types 5 Double click on Reader 6 Select the ...

Страница 37: ...tings on the Logical Device 1 Go to Hardware Configuration 2 Expand the appropriate Site 3 Select the appropriate class for example Readers 4 Double click the Logical Device 5 Select the tab Logical Device Details 6 Double click Reader 7 Select the tab Reader Settings Figure 16 Edit Reader Settings ...

Страница 38: ...s Table 1 Configuration Options using DKR readers without keypad Configuration Options HW Template and Logical Device Logical Device Only Keypad Mode None X LED Mode SNET X SNET Type DKR X Default Mode Card Only X Card Format SNET DKR Format X Table 2 Configuration Options Using DKR Readers with Keypad Configuration Options HW Template and Logical Device Logical Device Only Keypad Mode Hughes X LE...

Страница 39: ...also be any of the other available options for example Card or PIN PIN only etc Table 3 Configuration Options Using MSR Readers without Keypad Configuration Options HW Template and Logical Device Logical Device Only Keypad Mode None X LED Mode SNET X SNET Type MSRK X Default Mode Card only X Card Format SNET MSR Format X Table 4 Configuration Options Using MSR Readers without Keypad Configuration ...

Страница 40: ...rately Each reader s address must be unique Figure 17 Wiring Diagram for SNET Reader and PW 6000 IC RS 485 Port B 5 1 Configuring PW 6000 panel properties To attach SNET readers to the PW 6000 IC you must modify the panel properties To configure the PW 6000 panel for use with SNET 1 Go to Hardware Configuration 2 Expand the appropriate Site 3 Go to Panels 4 Double click the panel 5 Check the SNET ...

Страница 41: ...er Board Use the PW 6000 2 reader board to connect one SNET reader to each Wiegand port on the 2 reader board Up to 2 SNET readers can be connected to this board When using this configuration the following rules apply This configuration is one to one Two readers can be connected to the PW 6000 2 reader board There may be one SNET reader per Wiegand port Only SNET address 1 can be used Readers may ...

Страница 42: ... readers manual to see if the reader supports 12VDC ATTENTION Certains lecteurs DKR MSR doivent être alimenté en 24 VCC uniquement Veuillez consulter la documentation du lecteur pour valider qu il supporte du 12 VCC Caution If the reader does not support 12VDC apply power separately to the readers ATTENTION Si le lecteur ne supporte pas du 12 VCC alimentez le lecteur à l aide d une alimentation sé...

Страница 43: ...or held open alarm is raised At the door held open time it beeps continuously until the door is closed The reader does not beep at all Reader Keypad mode The LED turns yellow awaiting PIN entry after card presentation The LED turns yellow awaiting PIN entry after card presentation Reader Keypad mode The LED turns yellow awaiting card presentation after entering PIN The LED turns yellow after first...

Страница 44: ... Require 2 card control Not a SEEP CHIP feature After first card presentation the LED blinks Green Off Table 5 Configuration Options Using MSR Readers without Keypad continued Event SEEP CHIP Behavior PW6KIC Behavior Table 6 Configuration Options Using MSR Readers without Keypad Feature Behavior Secure Mode Allows an operator to monitor access on a door and manually grant deny access Card or PIN A...

Страница 45: ......

Страница 46: ... 135 W Forest Hill Avenue Oak Creek WI 53154 414 766 1700 414 766 1798 Fax European Office Boblingerstrasse 17 D 71101 Schonaich Germany 49 7031 637 782 49 7031 637 769 Fax www honeywell com Specifications subject to change without notice Honeywell All rights reserved 800 00005V3 ...

Отзывы: