![Honeywell PS1201A00 Скачать руководство пользователя страница 1](http://html.mh-extra.com/html/honeywell/ps1201a00/ps1201a00_installation-instructions-manual_152244001.webp)
69-2673EFS-01
INSTALLATION INSTRUCTIONS
PS1201A00, PS1202A00 and
PS2401A00 Replacement Power
Supplies for Electronic Air
Cleaners
APPLICATION
This power supply board has a selectable ionizer current output. Selection of the
correct ionizer current is accomplished by moving the P5 shorting bar to the proper
position. See table below.
Table 1.
*Default setting.
Power
Supply
Input
Voltage
Range
(Vac)
Input
Frequency
(Hz)
Input
Current (A)
Output
Ionizer
Voltage
(Vdc)
Output Ionizer
Current (mA)
(Selected by P5
shorting bar
position)
PS1201A00 102-132 Vac 50 / 60
0.4 7500/
8150*
2.1/1.65/1.29/1.05*/
0.9/0.25
PS1202A00 102-132 Vac 50 / 60
0.4 7500/
8150*
2.1/1.65/1.29/1.05*/
0.9/0.25
PS2401A00 204-264 Vac 50 / 60
0.2 7500/
8150*
2.1/1.65/1.29/1.05*/
0.9/0.25