Appendix E: Canadian Versions of SLC Devices
UL-listed SLC Device
ULC-listed SLC Device
Description
Detectors
FSP-951
FSP-951A
Analog, addressable intelligent smoke detector that uses a photoelectric
sensing chamber. Listed for use in ducts. Designed to provide open area
protection. FlashScan and CLIP mode. White.
FSP-951-IV
FSP-951A-IV
Analog, addressable intelligent smoke detector that uses a photoelectric
sensing chamber. Listed for use in ducts. Designed to provide open area
protection. CLIP mode only. Ivory.
FSP-951R
FSP-951RA
Analog, addressable intelligent photoelectric sensor with remote test
capability. For use with DNR(W) in US; for use with DNRA in Canadian
applications. FlashScan and CLIP mode. White.
FSP-951R-IV
FSP-951RA-IV
Analog, addressable intelligent photoelectric sensor with remote test
capability. For use with DNR(W) in US; for use with DNRA in Canadian
applications. CLIP mode only. Ivory.
FSP-951T
FSP-951TA
Adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C).
FlashScan and CLIP mode. White.
FSP-951T-IV
FSP-951TA-IV
Adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C).
Intelligent Photo/Temperature Detector. CLIP mode only. Ivory.
FST-951
FST-951A
High temperature sensor with 190°F (87.8°C) fixed temperature alarm.
FlashScan and CLIP mode. White.
FST-951-IV
FST-951A-IV
High temperature sensor with 190°F (87.8°C) fixed temperature alarm. CLIP
mode only. Ivory.
FST-951R
FST-951RA
Incorporates a thermal rate of rise of 15°F (9.4°C). FlashScan and CLIP
mode. White.
FST-951R-IV TC808B3102-
IV
FST-951RA-IV
Incorporates a thermal rate of rise of 15°F (9.4°C). CLIP mode only. Ivory.
FST-951H
FST-951HA
High temperature sensor with 190°F (87.8°C) fixed temperature alarm.
FlashScan and CLIP mode. White.
FST-951H-IV
FST-951HA-IV
High temperature sensor with 190°F (87.8°C) fixed temperature alarm. CLIP
mode only. Ivory.
FAPT-851 (Acclimate™)
FAPT-851A
Intelligent detector that combines a photoelectric sensing chamber and fixed
temperature heat detection (135°F/57.2°C). FlashScan capable.
FSB-200, FSB-200S
FSB-200A, FSB-200SA
Addressable, intelligent, single-ended beam smoke detector with built-in
sensitivity testing. FlashScan and CLIP mode.
FSI-851
FSI-851A
Addressable, intelligent smoke detector that incorporates an ionization
sensing chamber. Designed to provide open area protection. FlashScan
capable.
FSP-851
FSP-851A
Analog, addressable intelligent smoke detector that uses a photoelectric
sensing chamber. Listed for use in ducts. Designed to provide open area
protection. FlashScan capable.
FSP-851T
FSP-851TA
Adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C).
FSP-851R
FSP-851RA
Analog, addressable intelligent photoelectric sensor that is remote test
capable. For use with DNR(W).
FST-851
FST-851A
Intelligent thermistor sensing circuit for fast response. Designed to provide
open area protection with 50 foot spacing capability. A fixed temperature
sensor with 135°F fixed temperature alarm. FlashScan capable.
FST-851R
FST-851RA
Incorporates a thermal rate of rise of 15°F (9.4°C). FlashScan capable.
FST-851H
FST-851HA
High temperature sensor with 190°F (87.8°C) fixed temperature alarm.
FSD-751PL
FSD-751PLA
Photoelectric Duct Detector, Low-flow.
FSD-751RPL
FSD-751RPLA
Photoelectric Duct Detector, Low-flow.
FSH-751
FSH-751A
Smoke detector provides early warning smoke detection in hostile
environments where traditional smoke detectors are not practical.
FSL-751
FSL-751A
An advanced intelligent photoelectric detector that uses a laser diode,
special optics, and signal processing to obtain extremely high sensitivity.
FSC-851
FSC-851A
Intelligent multi-criteria detector that combines photoelectric sensing, heat
detection, carbon monoxide and flame.
FCO-851
FCO-851A
Addressable, intelligent detector that combines a photoelectric sensing
chamber combined with Carbon Monoxide (CO) sensors. FlashScan mode
only.