MPA1 User Guide
Planning for the Firmware Upgrade
Note
The Secondary panels must be upgrade first in any order and then upgrade
the Primary panel last.
The Secondary panel Firmware upgrade through panel web page is not
recommended. Refer the below two sections to upgrade the Secondary
panels.
For primary panel, plan 30 minutes (approximately) to upgrade for the
OS
+
Application
Note
If a Secondary panel doesn’t come on line with the primary perform a manual
“Reboot” of the Secondary panel.
Ethernet Virtual Loop (EVL):
Step # 1.
“Unregister” the Secondary panels
Step # 2.
Perform a Factory Reset, to make the Secondary panel as Primary.
Step # 3.
Upgrade the firmware
Step # 4.
Configure the panels back to Secondary and manually “Reboot”
Step # 5.
"Re-register" Secondary panels manually in the Primary panel
Remember to return their configuration back to a downstream panel once the upgrade has
been successfully completed.
The firmware and Operating System (OS) can be downloaded from the Honeywell
Download Center at the following site:
https://mywebtech.honeywell.com/
Updating the MPA1 Panel Using the Web Interface
Step 1: Installing the new File
1. Navigate to the web server
Panel Configuration
>
Advanced
>
File Management
>
Upload (To Panel)
.
2. Under
Download (To Panel)
click
Browse
to locate the application bin file.
3. Select the file and click
Download
. Click
OK
to continue. Once the "Download to
primary panel complete; now processing the image" message pops up, click
OK
again.
4. You will see the
Download
to primary panel complete; now processing the image
message once again. Click
OK
. This time a reboot will be triggered and you will see the
message: "
The Panel is now rebooting. Wait
30 minutes
, then click Refresh
and log back in
."
Step 2: Verifying that the Installed Versions are Correct
1. Navigate back to the web server
Menu > Panel Configuration > Settings
.
Содержание MPA1
Страница 1: ...Document 800 26311_Rev B July 2020 Access Control Unit MPA1 User Guide ...
Страница 2: ...Revisions Rev Date Revisions A 02 2020 Document created B 07 2020 Document updated with ULC Features ...
Страница 14: ... 13 Document 800 26311_ A April 2020 This page is intentionally left blank ...
Страница 72: ... 75 Document 800 26311_ A April 2020 This page is intentionally left blank ...
Страница 100: ...www honeywell com security 104 MPA1 User Guide This page is intentionally left blank ...
Страница 109: ... 113 Document 800 26311_ A February 2020 Click Open to load the file Confirm Yes when this warning comes up Success ...
Страница 119: ... 125 Document 800 26311_Rev B July 2020 ...