MICRO SWITCH™ GSX Series
Issue 8
50032072
18
sensing.honeywell.com
Designation and
Utilization Category
Rated Operational Current Ie (A) at Rated Operational Voltage Ue (V)
24 V
120 V
240 V
380 V
480 V
500 V
600 V
AC15
A300
—
6 A
3 A
—
—
—
—
AC15
A500
—
6 A
3 A
1,9 A
1,5 A
1,4 A
—
AC15
A600
—
6 A
3 A
1,9 A
1,5 A
1,4 A
1,2 A
DC13
Q300
2,8 A
0,55 A
0,27 A
—
—
—
—
Rated thermal current (Ith)
10 A
Sealing
IP67; NEMA 1, 3, 4, 12, 13
Rated impulse withstand (Uimp)
2500 V
Pollution degree
3
Rated insulation voltage (Ui)
300 V, 500 V, 600 V
Operating temperature range
-40
°
C to 70
°
C [-40
°
F to 158
°
F]
Short-circuit protective device (type/maximum rating)
Class J fuse (10 A/600 V)
Expected mechanical life
1,000,000 operations
Conditional short-circuit current
1000 A
Electrical rating for gold-plated contacts
10
µ
A to 100 mA, 1 Vac/Vdc to 50 Vac/Vdc
•
Low Voltage Directive 73/23/EEC, as amended by directive 93/68/EEC.
•
Machinery Directive 98/37/EEC only as the directives relate to the components being used in a safety function.
•
Sira 08ATEX1073X
•
IEC Ex SIR 08.0021X
•
IEC/EN60947-1, IEC/EN60947-5-1.
•
MCTF (Mechanical Life): > 1,000,000 Cycles with Single Sided Confidence Limit of 100%. *
•
MCTF (Electrical Life): > 25,000 Cycles with Single Sided Confidence Limit of 100%. *
•
Highest SIL Capability: SIL3 (HFT:1), IEC 61508-2: 2010
* (* APPLICABLE ONLY FOR GSX***A** - * THROUGH GSX***D** - *)
•
Proof Test Interval: 1 Year