Honeywell MAXPRO Intrusion MPIP2000U/3000U Series
Installation and Setup Guide
800-23044 Rev. A draft_11
37
#
LED Colour
Description
B
Green
Power input available on main board.
Off
No power available on main board.
C
Green
V-Plex 1: loop OK.
Off
V-Plex 1: loop shorted or data bus not running.
D
Green
AUX1/IB2 bus 1: power on AUX1 is available.
Off
PTC for AUX1 is resetting, or other trouble on the bus.
E
Amber (left)
Ethernet amber LED (left): network connection is
working.
Green (right)
Ethernet green LED (right): flashes when the system
is sending or receiving data over the network.
F
Green
AUX3: power on AUX3 is available.
Off
PTC for AUX3 is resetting.
G
Green
AUX2/IB2 bus 2: power on AUX2 is available.
Off
PTC for AUX2 is resetting, or other trouble on the bus.
This LED is only available on the MPIP3000 series.
H
Green
V-Plex 2: loop OK.
Off
V-Plex 2: loop shorted or data bus not running.
This LED is only available on the MPIP3000 series.
3.6
Connecting the Cabinet Tamper Switches
The cabinet comes with a tamper switch in the cabinet door to prevent opening
of the cabinet door. Use the included cable to connect the tamper switch to the
control panel (D on page 34).
Optionally, there is a knockout available in the cabinet back that can be used to
fit an additional tamper switch to prevent removal of the cabinet from the wall.
From
To Control Panel Terminal
Tamper switch in cabinet door
T-LID
Tamper switch in cabinet back
(optional, not included)
T-WALL
The system will report tamper events on Area 1, the system area.
l
If Area 1 is disarmed, the system will report the tamper event as a fault
condition.
l
If Area 1 is armed, the system will report the tamper event as an alarm.