Honeywell Lyric RF6GB Скачать руководство пользователя страница 1

 

 

 

The RF6GB is a wireless glassbreak detector intended for use with Honeywell controls that support SiX™ 

Series devices. 

Mounting 

 

The RF6GB can be mounted 

on the wall or on the ceiling. 

 

within 7.6 m (25 feet) of the 

protected glass; 

 

within clear view of the 

protected glass; 

 

at least 2 m (6.5 feet) from the 

floor; 

 

at least 1 m (3.3 feet) from 

forced air ducts; 

 

at least 1 m (3.3 feet) from 

sirens or bells greater than 5 

cm (2 inches) in diameter. 

 

between the protected glass 

and any heavy window 

coverings. 

 

when heavy window coverings 

are present, the detector can 

be mounted on the window 

frame. 

 

Avoid mounting the detector 

on the same wall as the 

protected glass, on free-

standing posts or pillars, or in 

rooms with noisy equipment 

(air compressors, bells, power 

tools, etc.), if this equipment is 

operated when the detector is 

armed. 

 

UL requirements:  

TBD

 

 

  

 

To remove the mounting bracket: 
Turn the top of the detector 15 degrees 

counter-clockwise and separate the 

mounting bracket. 
Note: Before mounting the RF6GB 

permanently, conduct Go/No Go tests (see 

control’s instructions) to verify adequate 

signal strength and adjust the device location 

and orientation as necessary. 

 

The RF6GB can be mounted on the wall 

or on the ceiling. 

 

The rear tamper plate MUST be mounted 

to a stud, solid wood, or with a robust 

wall anchor. 

 

 

BETA DRAFT – 01/12/15 

Содержание Lyric RF6GB

Страница 1: ...ounted on the window frame Avoid mounting the detector on the same wall as the protected glass on free standing posts or pillars or in rooms with noisy equipment air compressors bells power tools etc if this equipment is operated when the detector is armed UL requirements TBD To remove the mounting bracket Turn the top of the detector 15 degrees counter clockwise and separate the mounting bracket ...

Страница 2: ...ED turns off and the device powers down Activate the tamper power down and up again or use the FG701 Glassbreak Simulator to restart the enrollment process Note Once enrolled in a system the detector cannot be used with another control panel until it is removed from the current control panel See the Control s instructions for details on removing devices Program the RF6GB Consult the Control s inst...

Страница 3: ...diagnosis The LEDs are not visible during Normal Mode to save power Test the RF6GB The RF6GB should be tested after installation and at least once a year Test Mode can be activated remotely from the Control Panel see Control Panel manual or on site with an FG 701 Glassbreak Simulator only when the system is disarmed Follow directions in the FG 701 Glassbreak Simulator Operating Instructions to act...

Страница 4: ... the Installation Instructions or User s Manual Unauthorized changes or modifications could void the user s authority to operate the equipment FCC IC STATEMENT This device complies with Part 15 of the FCC Rules and RSS 210 of Industry Canada Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received ...

Отзывы: