Honeywell IS3050A Скачать руководство пользователя страница 1

 

 

 

 

IS3050A Passive Infrared Motion Sensor with Anti-Mask  -  Installation Instructions

 

QUICK LINKS 

Mounting Location Guidelines 
Open the Sensor 
Mount the Sensor 
Sensor Components and Settings 
Wire the Sensor 

Wiring Examples 
Walk Test the Sensor 
Detection Patterns 
Remote LED Enable 
Relay Operation 

Mask Condition 
Troubleshooting 
Sensor Specifications 
Accessories 
Approval Listings 

 

 

   

 
 
 

 

 

 

 

 

Mounting location guidelines: 

  The optimal range is obtained at a mounting height  

of 7’ 6” (2.3m).   

  Allow a clear line-of-sight to all areas to protect. 

  Avoid mounting anything within 12” (30cm) in front of the sensor.* 

  Do not directly face windows. 

  Avoid close proximity to moving machinery, fluorescent lights, and heating/cooling sources. 

  Not for use in applications with pets.

 

 

1.  Turn the arrow to point to the Unlock symbol.   
2.  Press firmly on housing latch. 
3.  Gently separate the front and rear housing. 

Содержание IS3050A

Страница 1: ...Specifications Accessories Approval Listings Mounting location guidelines The optimal range is obtained at a mounting height of 7 6 2 3m Allow a clear line of sight to all areas to protect Avoid mounting anything within 12 30cm in front of the sensor Do not directly face windows Avoid close proximity to moving machinery fluorescent lights and heating cooling sources Not for use in applications wit...

Страница 2: ... 2 A Wall mounting holes B Corner mounting holes The rear tamper plate MUST be mounted to a stud solid wood or with a robust wall anchor See wiring details and examples on page 3 ...

Страница 3: ...one input All alarm tamper and trouble anti mask events are alarms when the system is armed or fault when disarmed To connect the sensor alarm output to one zone input and the tamper and trouble anti mask outputs to a second zone input The alarm relay is wired to one zone the tamper and trouble anti mask are wired to another zone the control panel differentiates alarm conditions from tamper and tr...

Страница 4: ...minutes then automatically exits test mode disables the LED and enters normal operation mode For an additional 10 minute walk test enable Walk Test mode again with the flashlight feature Note During power up and walk test modes the LED is active regardless of the LED Enable Disable DIP switch setting Flashlight Feature 1 Use a flashlight with a bright light beam and stand within 4 1 2 m of the sen...

Страница 5: ...oes not clear replace the sensor SPECIFICATIONS Range 53 x 72 16 m x 22 m Wall Mounting Height 6 9 8 9 2 1 m 2 7 m Optimal 7 6 2 3 m Power 9 0 16 VDC UL 9 5 15 VDC 15 mA typical 16 mA maximum AC Ripple 3 V peak to peak at nominal 12 VDC Alarm Relay Energized Form A 30 mA 25 VDC 22 Ohms resistance maximum Alarm Relay Duration 3 seconds Trouble Relay Energized Form B NC 30 mA 25 VDC 22 Ohms resistan...

Страница 6: ...in a residential installation However there is no guarantee that interference will not occur in a particular installation If this equipment does cause interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient the receiving antenna until interfe...

Отзывы: