Honeywell IS3016A Скачать руководство пользователя страница 1

 

 

 

 

IS3016A  Passive Infrared Motion Sensor with Anti-Mask  -  Installation Instructions 

QUICK LINKS 

Mounting Location Guidelines 
Open the Sensor 
Mount the Sensor 
Sensor Components and Settings 
Wire the Sensor 

Wiring Examples 
Walk Test the Sensor 
Detection Patterns 
Remote LED Enable 
Relay Operation 

Mask Condition 
Troubleshooting 
Sensor Specifications 
Accessories 
Approval Listings 

 

 

   

 
 
 
 

 

 

 

 

 

1.  Turn the arrow to point to the Unlock symbol.   
2.  Press firmly on housing latch. 
3.  Gently separate the front and rear housing. 

[EN] = approved installation. 

Mounting location guidelines: 

•  The maximum range is obtained at a mounting height  

of 2.3m (7’ 6”).   

•  Allow a clear line-of-sight to all areas to protect. 

•  Avoid mounting anything within 30cm (12”) in front of the sensor. 

•  Do not directly face windows. 

•  Avoid close proximity to moving machinery, fluorescent lights, and 

heating/cooling sources. 

•  Not for use in applications with pets.

 

 

Содержание IS3016A

Страница 1: ...ns Accessories Approval Listings 1 Turn the arrow to point to the Unlock symbol 2 Press firmly on housing latch 3 Gently separate the front and rear housing EN approved installation Mounting location guidelines The maximum range is obtained at a mounting height of 2 3m 7 6 Allow a clear line of sight to all areas to protect Avoid mounting anything within 30cm 12 in front of the sensor Do not direc...

Страница 2: ... 2 A Wall mounting holes B Corner mounting holes The rear tamper plate MUST be mounted to a stud solid wood or with a robust wall anchor See wiring details and examples on page 3 ...

Страница 3: ... configured to two loops 1 Close the sensor and apply power to the sensor Initialization is complete when the LED stops flashing slowly about 20 seconds 2 Walk through the detection area and observe the LED Walk test mode is active for 10 minutes then automatically exits test mode disables the LED and enters normal operation mode For an additional 10 minute walk test enable Walk Test mode again wi...

Страница 4: ...mask condition when a variety of materials and reflective objects are placed within 50mm 2 inches in front of the sensor To avoid false mask alarms follow the mounting guidelines shown in Step 1 Clearing an Anti Mask Condition When most masking materials or objects are removed the anti mask condition will be cleared after several seconds When the cause of the anti mask condition is any type of spr...

Страница 5: ...ket SMB 10T P N 0 000 155 01 Swivel Mount Bracket w Tamper Note The accessories are not covered by certifications APPROVAL LISTINGS EN50131 2 2 2008 Security Grade 3 Environmental Class II Suitable for connection to an EN 60950 Class II Limited Power Source PD6662 2010 Note In EN 50131 2 2 compliant installations mount the sensor at 2 3m do not use only the right side corner mounting holes enable ...

Страница 6: ...ngdom Please contact your local authorised Honeywell representative for product warranty information 2013 Honeywell International Inc Honeywell and DUAL TEC are registered trademarks of Honeywell International Inc All other trademarks are the properties of their respective owners All rights reserved Made in China P N 800 15672 Rev B Tel 44 0 1698 738200 Email UK64Sales Honeywell com www honeywell ...