Switching the High Side with External Power
Drive a DC Relay to Control an AC Load
While the reader outputs are designed to switch DC loads, they can also drive
relays that control AC loads.
Driving a DC Relay. The external relay provides dry contacts to the AC motor.
Note:
In many installations, the relay and AC wiring must be placed in an enclosure that
meets local fire code regulations.
External
indicator
lamp
External
power
5-
2
4 VDC
+ -
Ground
+Output
- Output
AC motor
120-230
VAC
External
relay
+ Output
+
5
V
Ground
- Output
Wiegand Support
The reader outputs can be used to provide Wiegand support for reading of tags.
The user App “myapp.zip” should be downloaded from the ftp site,
https://hsmftp.honeywell.com
.
The App should be installed on the Web interface. Log in to the web browser
interface and click
Edgeware Applications > Install User Application > choose
file > upload