HW3000/HW3000L Portable Electrical Generator Owner’s Manual
www.honeywellgenerators.com
25
Transporting Generator
Transporting Generator
When transporting the generator:
•
Press the engine control switch to the STOP position.
•
Turn the fuel shut-off valve to the OFF position.
•
Keep the generator level to prevent fuel spillage.
•
Place pins in the handle and handle bracket before
moving the generator.
Storing Generator
Before storing generator for extended period of time:
•
Be sure storage area is free of excessive humidity
and dust.
•
Refer to Table 5 for recommended preparation proce-
dures.
To prepare generator for long-term storage:
1.
Drain fuel into suitable container (see page 26).
2.
Change engine oil (see page 19).
3.
Remove spark plug (see page 23).
4.
Add a tablespoon of clean engine oil into spark plug
hole.
5.
Place rag over spark plug hole and pull recoil starter
handle slowly to turn engine and distribute oil.
6.
Reinstall spark plug.
Hot engine or exhaust system can cause serious
burns or fires. Cool generator completely before
transporting or storing.
NOTICE
NEVER drop, strike, or place heavy objects on generator
when transporting.
WARNING
NOTICE
Follow service procedures for preparing generator for stor-
age. Inadequate or improper care of generator can result in
damage to generator components and will void limited war-
ranty.
Storage Time
Recommended Preparation
Less than 1
month
No preparation required.
1 to 2 months
Fill fuel tank with fresh gasoline and
add gasoline conditioner
*
.
*
Use gasoline conditioners formulated to extend storage life.
Contact authorized generator dealer for conditioner recommen-
dations.
2 months to 1
year or more
See procedure below.
TABLE 5. Recommended Service Procedures Based on Storage
Time
Fuel and its vapors are extremely flammable and
explosive under certain conditions.
• NEVER smoke or allow flames or sparks near genera-
tor or where gasoline is stored.
DANGER
Содержание HW3000
Страница 87: ... ...