Starting Generator
14
www.honeywellgenerators.com
HW3000/HW3000L Portable Electrical Generator Owner’s Manual
Starting Generator
1.
Place generator outside in a well-ventilated area.
2.
Confirm the circuit breakers are set.
3.
Turn the fuel shut-off valve to the ON position.
4.
Move the choke control to the ON position.
5.
Press the engine control switch to the RUN position.
6.
Grip recoil starter handle and pull slowly until you feel
slight resistance.
7.
Apply a swift pull to start the engine and carefully
return the recoil starter handle to its original position.
This may need to be repeated 2-3 times until the
engine starts.
8.
As the engine warms up and RPM stabilizes, gradu-
ally push the choke control to the OFF position.
Thoroughly read and understand all information
provided in this Owner’s Manual before operating
generator.
NOTICE
It is very important to maintain proper level of engine oil to
keep engine in good running condition.
• Check engine oil level prior to each use.
Starting generator with appliances connected can cause
permanent damage to appliances.
• NEVER start generator with electrical appliances
plugged in and turned on.
NOTICE
Keep the generator at a minimum of 6 feet (2 meters) from
any building, object, or wall.
FIGURE 16:
Circuit Breaker Position
FIGURE 17:
Fuel Shut-off Valve — ON/OFF Position
FIGURE 18:
Choke Control
WARNING
Set
Tripped
ON
OFF
FIGURE 19:
Engine Control Switch
FIGURE 20:
Recoil Starter Handle
NOTICE
NEVER allow the recoil starter handle to snap back against
the engine. Return it gently to prevent damage to the starter.
NOTICE
If engine will not start, move the choke control to the OFF
position to reduce fuel to the engine.