TRANSMISSION RISK
AIR MONITOR
USER
MANUAL
Страница 1: ...TRANSMISSION RISK AIR MONITOR USER MANUAL ...
Страница 2: ... Wallmountkit separateinstructionsprovidedinkit OPERATION 1 HTRAMisadesktoporwall mounteddevice Werecommend to keep it plugged in so it s powered by the external USB charger There is a rechargeable battery inside that will supply power for up to 10 hours but we recommend keeping the device plugged in to conserve battery life 2 DeviceOn Off WhenthedeviceinOFFstatus pushandhold buttonfor3secondstotu...
Страница 3: ...for 3 seconds to turn it OFF USERINTERFACE 400 Low Medium High CO PPM SYMBOL FUNCTION Bluetooth icon Batterycapacitylevel USBpowerinput iconwillshowonscreen CO2concentrationreading Risklevelbasedonmultiplefactorssuchas CO2 Temp RHandactivityleveletc Power button StatusLEDs LCDscreen Power inputport 2 ...
Страница 4: ...thedevicewill initiallyshow forapproximately1minute QUICK START GUIDE Makesurethesecomponentswereinthebox Ifanyaremissing please contact the company from which you purchased the device as soon as possible Step 1 Make sure you have everything then charge the device Air Monitor USB Cable User Manual ConnectthemicroUSBendtothedevice andtheUSBconnector 3 ...
Страница 5: ...orGoogle stores orby scanningtheappropriate QRcodeshownbelowifyourphone has a scanning app or embedded capability Launch the app Then complete the connection and setup byfollowingtheBluetoothpairingprocessinthisdocument toapoweradapterorcomputer Keepplugged inuntilfullycharged Make sure the working environment is supported by Bluetooth andwirelesswithInternetaccess anda user suppliedsmartphoneusin...
Страница 6: ...ter it on the mobile app to finish the verification process 4 Provide your first name and last name create your password and complete the self registration process 5 Go back to the main screen to login to the mobile app For individual users with less than 10 devices we recommend going through the self registration process via the mobile application For enterprise users with more than 10 devices we...
Страница 7: ...ick VERIFY ACCOUNT to validate purchase of your devices 4 Enter your email address and click to send the verification code 5 Check your email for the verification code and enter it on the web portal then click NEXT 6 Enter the required organization information 7 Enter the Organization Administrator information and then click SUBMIT to finish the registration process 1 Open the App and enable mobil...
Страница 8: ... the PIN CODE shown on the device s screen 6 If two or more devices Bluetooth are activated you can use the serial number to identify which device is to be paired The serial number can be found on the back side of the device 7 Input the 6 digit PIN CODE Then click Connect 8 When the Bluetooth icon on the device s screen stops blinking pairing is complete 9 If you are individual user and want to co...
Страница 9: ...anizational setting e g schools restaurants we recommend physically protecting the device by placing a lock on the device enclosure and enabling only authenticated access to the secure devices Ensure that only authorized personnel have the required keys to physically access the devices 10 If you are an enterprise user and your organization has secured WIFI network please reach out to your organiza...
Страница 10: ...the device to set the alarm threshold levels based on the user s parameters and local regional and state requirements Note If Custom Settings are used the user is solely responsible for validating that those alarm settings meet their specific requirements 500ppm 7 32 infectionrisk 800ppm 25 25 infection risk High Activity Setting Custom Setting 700ppm 3 40 infectionrisk 1000ppm 5 41 infection risk...
Страница 11: ...smission An increase from Green to Yellow Yellow to Red or Green to Red does not indicate a linear increase in potential transmission risk within one Activity Setting Any increase in potential transmission risk across multiple Activity Settings is also not linear Numerous factors including without limitation interaction among individuals in a room the number of infected individuals present and the...
Страница 12: ... on activity levels Low activity Reading quietly talking Breathing rate susceptibles 0 252 m3 h CO2 emission rate person 0 0052 273 K and 1 atm Quanta exhalation rate infected 9 4 quanta h activity duration for 30 minutes Medium activity Eating talking loudly Breathing rate susceptibles 1 2 m3 h CO2 emission rate person 0 012 273 K and 1 atm Quanta exhalation rate infected 170 quanta h activity du...
Страница 13: ... Depositiontosurfaces Decayrateofthevirus defaultper https tinyurl com covid estimator defaultper https tinyurl com covid estimator defaultper https tinyurl com covid estimator defaultper https tinyurl com covid estimator 0 62 h 1 0 3 h 1 TotalNpeoplepresent 20 ft Additionalcontrolmeasures 0 h 1 Fractionofpopulationimmune InfectedPeople 1 person 0 Exhalationmaskefficiency 0 Inhalation mask efficie...
Страница 14: ...ase click the Data History tab on the mobile app 2 You can switch among CO2 temperature and humidity to view the device s history It can be viewed by day week or month 3 The device s maximum data storage is approximately 90 days It will only keep the most recent 90 days worth of data DATAHISTORY Quanta Concentration initial value 0 00 novirusatthebeginning 13 ...
Страница 15: ...ound is enabled the buzzer will beep at medium or high alarm Whenthealarmis sounddisabled the buzzer will not beep when medium or high alarm is triggered Turn off display users can turn off display on the mobile app When display is off users can wake up the device by pushing the top button Then the display will auto off in 2 minutes SPECIFICATIONS PARAMETER CHARACTERISTIC Dimensions H W D 80mm 80m...
Страница 16: ...r reduce virus transmission nor mitigate viruses that may be present nor does it detect or warn against the presence of any virus including but not limited to COVID 19 Even at lower risk levels caution is Housingmaterials Aluminumalloy Display TFT Inputvoltage 5V Inputcurrent 1A Battery Lithium ionrechargeablebattery10 hourbatterytime Batterycapacity 2 600 mAh USBport Micro USB Operatingtemperatur...
Страница 17: ...ence expertise and other available tools the suitability of any product or service it may offer or recommend to the end user Buyer is responsible for determining whether the product is appropriate for use under certain international federal state or local guidelines and is likewise responsible for determining whether the HTRAM qualifies for any government programs including without limitation reim...
Страница 18: ...etect for levels of CO2 that would make for an unsafe or unsuitable breathing environment WARRANTY Under normal use and maintenance that is consistent with Honeywell manuals and instructions Honeywell warrants that for a period of one 1 year from the date of purchase all components of this product except software and software components shall be free from faulty workmanship and defective materials...
Страница 19: ...mer notifies Honeywell in writing of any alleged defect within 30 days of discovery and it is determined by Honeywell that any component of the product except software components is defective due to faulty workmanship or defective materials then Honeywell shall repair or replace such Product at Honeywell s sole discretion Repair or replacement of a product or any part thereof does not extend the w...
Страница 20: ...licit warranties are the only warranties provided by Honeywell with respect to the product and are in lieu of all other warranties express or implied Any implied warranty or guarantee including merchantability fitness for a particular purpose and non infringement of third party rights shall not apply This warranty only applies to the main unit of the product and does not cover the package manuals ...
Страница 21: ...vide any additional warranty or guarantee express or implied DISPOSAL This product contains a lithium ion battery and alumi num alloy materials Upon receipt of the product the customer is responsible for proper use transport storage and disposal of the product based on the battery and material type including but not limited to applicable governmental requirements for proper disposal CAUTION Risk o...
Страница 22: ...ps honeywell com us en products safety gas and flame detection portables honeywell trans mission risk air monitor SIMPLIFIED EU DECLARATION OF CONFORMITY Honeywell Safety and Productivity Solutions certifies that the CO2 sensor in Honeywell Transmission Risk Air Monitor HTRAM device is maintenance free in normal indoor environments No calibration at end user is needed The accuracy of the sensor is...
Страница 23: ...nd Productivity Solutions SIMPLIFIED UK DECLARATION OF CONFORMITY This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation 22 ...
Страница 24: ...ame detection portables honeywell trans mission risk air monitor United Kingdom Contact Life Safety Distribution GMBH Address Hatch Pond House 4 Stinsford Road Nuffield Industrial Estate Poole Dorset BH17 0RZ UK Phone 41 0 44 943 4300 Nominal Voltage 3 6V Rated Capacity 2480 mAh 8 93Wh Typical Capacity 2600 mAh 9 36Wh Limited Charging Voltage 4 2V Manufacturer SCUD Fujan Electronics Co Ltd Red Wir...
Страница 25: ... point WARNING TO PREVENT INJURY DO NOT DISASSEMBLE PUNCTURE CRUSH HEAT ORBURN Use the authorized charger only Never disassemble by yourself Never short circuit the battery Dispose of the battery properly Exposing the battery to an open flame could cause an explosion Strangulation HAZARD Children have STRANGLED in cords Keep this cord out of reach of children more than 3 ft 1m away Do not use with...
Страница 26: ... device can only charge the battery indoors in a 0 C to 40 C 32 F to 104 F temperature range The charging time from empty to full battery is approximately 6 hours During charging the device surface will have a slight temperature rise These instructions and specifications are subject to change without notice at Honeywell s sole discretion For more information and the most recent User Manual go to h...
Страница 27: ...oneywell com Honeywell Safety and Productivity Solutions 9680 Old Bailes Road Fort Mill SC 29707 United States Contact us US Tel 800 430 5490 Fax 800 322 1330 Canada Tel 888 212 7233 Fax 888 667 8477 informationsp honeywell com ...