![Honeywell HM750 Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/honeywell/hm750/hm750_installation-instructions-manual_151318002.webp)
HM750A1000
33-00289—01
2
Table 1. Specifications.
Fig. 1. Specification label location.
CAUTION
Servicing
Disconnect main power before any servicing.
• The plumbing and electrical compartments
contain high voltage components and wiring.
Access should be limited to authorized
personnel only.
• During and following operation of the
humidifier, the steam and components in
contact with the steam such as the steam lines,
steam distributors, and condensate lines can
become hot and can burn if touched.
• Honeywell does not accept any liability for
installations of humidity equipment installed by
unqualified personnel or the use of
parts/components/equipment that are not
authorized or approved by Honeywell.
• To maintain warranty, only Honeywell
approved parts and cylinders may be used in
the operation of the product.
CAUTION
Electrical
All electrical work should be done according to
local and national electrical code.
Electrical connection to be performed by a licensed
electrician.
Unit recommended to be powered by a dedicated
GFCI circuit.
CAUTION
Plumbing
Plumbing to be performed by a licensed plumber.
Drain water from humidifier can be very hot. Do not
drain to public sink.
All plumbing work should be done according to
local plumbing code.
CAUTION
Installation
Do not mount on surfaces hotter than 176 ºF
(80 ºC).
Do not mount in area where freezing can occur.
Do not mount on vibrating surface.
Do not mount on floor.
The HM750 produces steam at atmospheric
pressure. No devices which could block steam
output should be connected to the steam outlet.
Steam lines must be installed so that no restriction
can produce backpressure in the humidifier.
Do not mount outdoors without protection against
rain, snow, condensation or equivalent.
CAUTION
Water quality
The Honeywell HM750 requires a cold water
connection from your home's main water supply
between 15-100 PSIG. A throttle valve may be
necessary, and a water shut-off valve is
recommended for safety.
Reverse Osmosis (RO)
and Deionized (DI) water must not be used.
Water conductivity is important to ensure the
electrode humidifier operates effectively.
Honeywell recommends 125-1200
μ
S/cm
(microsiemens/cm).
Volts
Steam Output
GPD
KW
Amps Phase
Max Ext.
Fuse
(Amps)
Standard
Cylinder
Net/Full
Weight
lbs. (kg)
Dimensions
(W x H x D)
110/120
11
1.5
12
1
15
HM750ACYL
15 / 20
(7.0 / 9.5)
10 x 18 x 7 in.
254 x 457 x 178 mm
220/240
22
3.0
MODE
L:
HM750
A100
0 1
PHASE:
1
HZ:
60
Co
un
try o
f or
igin
: C
an
ada
Pay
s d
’orig
ine
: Ca
nad
a
Au
to-A
dap
tive
Pro
fes
sio
nall
y se
rvic
ed o
nly
.
En
tretien
par
des
pro
fess
ionn
els s
eule
men
t.
S/N
DATE
CODE
205X
HUM
IDIFIE
R
VO
LT
110
-12
0
220
-24
0
AM
P
12
12
GPD
11
22
KW
1.5
3.0
HM750
Statu
s
Servic
e
Power
Idle
Filling
Humid
ifying
Draining
Cylind
er
Fault
Drain
Fault Code
s In Front Cov
er
MODEL:
HM750A1000
1
PHASE:
1
HZ:
60
Country of origin: Canada
Pays d’origine : Canada
Auto-Adaptive
Professionally serviced only.
Entretien par des professionnels seulement.
S/N
DATECODE
205X
HUMIDIFIER
VOLT
110-120
220-240
AMP
12
12
GPD
11
22
KW
1.5
3.0
M37184
MODEL:
HM750A10
00 1
PHASE:
1
HZ:
60
Countr
y of ori
gin: C
anada
Pays d’
origine :
Canad
a
Auto-A
daptiv
e
Profes
sionall
y servic
ed only
.
Entretie
n par de
s profes
sionnels s
eulemen
t.
S/N
DATECO
DE
205X
HUMIDIFIER
VOLT
110-12
0 220
-240
AMP
12
12
GPD
11
22
KW
1.5
3.0