CONNECTION:
DIMENSIONS:
INSTALLATION:
SPECIFICATIONS:
You must be fully aware of all the
distinctive features and precautions
related to this camera before installing it.
No.
#1
#2
Function
Video Output
Power Input
Remark
1.0 Vp-p
12VDC(10V~15V),
0.15A / 1.8W(Max)
Terminal Color
Yellow
Red
• The wire is polarized.
• Use 12VDC power source.
12VDC Power Type
Video Output
GND
Video
(Yellow)
Power
- 12VDC
(Red)
#1
#2
This manual explains the installation and operating method for the
color dome camera. Before installation, make sure you are familiar
with this product's special features and proper operating technique.
Ceiling
Draw out power / video wires
to the connecting places.
3
Stick the guide pattern on the
wall or ceiling.
1
After fixing it, adjust its pan
base and tilt base properly.
5
Drill four holes according to
the guide pattern then insert
anchors into the drilled holes.
2
Put the dome cover over the base.
6
Fix the dome cover on the base
by L-Wrench.
7
Fix the camera to a celling
using four screws.
4
Design and specifications are
subject to change without notice.
Guide Pattern
Mounting
Screw
Dome Cover
L-Wrench
Dome Base
Ø 85
Operation
Manual
Guide Pattern
Mounting Screw
L-Wrench
Service Monitor Cable
!
USER INFORMATION:
PRECAUTION:
CAUTION!
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE
COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
All the warnings and instructions of this manual should be followed.
Keep enough space around the unit for ventilation.
Slots and openings on the monitor should not be blocked.
During flashes of lightning or cracks of thunder, or when the system
is not used for a long time, unplug the system power supply to
protect the unit from lightening or power surges.
Do not attempt to service this unit yourself as opening or removing
covers may you to dangerous voltage or other hazards. Please refer
all servicing to qualified service personnel.
Do not place anything on top of the unit that might spill or fall into it.
To reduce the risk of fire or electric shock, do not expose this appliance
to rain or moisture.
Remove the plug from the outlet before cleaning. Do not use liquid
aerosol detergents. Use water damped cloth for cleaning.
THE GRAPHIC SYMBOLS WITH SUPPLEMENTAL MARKING ARE ON THE BOTTOM
OF THE SYSTEM.
"WARNING-TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THE UNIT
TO RAIN OR MOISTURE"
The lightning flash with arrowhead symbol, within an equilateral
triangle, is intended to alert the user to the presence of un-insulated
"dangerous voltage" within the product's enclosure that may be of
sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to
alert the user to the presence of important operating and maintenance-
(servicing) instructions in the literature accompanying the appliance.
Explanation of two Symbols
The image does not
appear on the screen.
Check the power source for the monitor
and camera and ensure that the voltage
and polarity are properly connected and
being supplied correctly.
The image on the
screen is dim.
Check if the lens is stained. If dirty,
clean the lens with a soft, clean cloth.
Adjust the Back Focus of the lens again.
The camera does not
work properly, the surface
of the camera case is hot,
and a black line appears
on the screen.
Check if you have connected the camera
to a proper power source and If there is
no problem with the power, turn the unit
off immediately and seek assistance from
our Customer Service department.
The screen blinks a lot.
Check if the camera is pointed toward
the sun or a fluorescent lamp.
Adjust the angle or location of the
camera if too much light is coming into
the screen.
TROUBLESHOOTING:
If you have trouble operating
your camera, refer to the following.
If the guidelines do not enable you to solve the problem,
contact an authorized technician.
360º
90º
360º
Horizontal
Pan
Tilt
Built-in camera
bracket makes it much
easier to rotate in any
direction.
3-axis
Signal System
Scanning System
Scanning Frequency (H)
Scanning Frequency (V)
Image Sensor
Total/Effective Pixels No.
S/N Ratio
Resolution
Video Output Level
Lens
Focus
Sync. System
Sensitivity
Electronic Shutter
White Balance
AGC
Input/Output Connector
Power Consumption
Dome Size (Ø)
Weight
NTSC : 525 Lines PAL : 625 Lines
2 : 1 Interlace
15.734kHz 15.625kHz
59.94Hz 50Hz
1/3 inch SONY Super HAD CCD
410K/380K 470K/440K
More than 48dB
530 TV Lines
1.0 Vp-p (75 Ohms, composite)
Fixed Lens (f=3.8mm)
Manual
Internal
0.3 Lux
1/60~10,000 Sec. 1/50~10,000 Sec.
Auto
Auto
Power(Red or Green Jack), Video(Yellow Jack)
12VDC (10V~15V) , 0.15A / 1.8W (Max)
85mm
Approx. 376g
Need Help?
Call 1.800.796.CCTV for sales, service and customer support.
www.honeywellvideo.com
P/N:3810-0084B
Rev 0 03/18
4.65” (118.8 mm)
3.35” (85 mm)
3.03” (77 mm)
2.87” (73 mm)
0.16” (4.1 mm)
2.36” (60 mm)
2.36” (60 mm)
4- 0.18” (4.5 mm)
• 1/3” SONY Super HAD CCD
• 530 TVL
• Built-in Fixed Lens (f=3.8mm)
• Min. Illumination : 0.3 Lux
• Auto White Balance
• AGC
• Vandal-Resistant Dome Housing
• Diameter of Bubble : 85mm
Operation
Manual
HD50
Series
READ AND KEEP THIS
OPERATION MANUAL
•S
im
ple to insta
ll