AC & Refrigeration Flush
Honeywell Genetron
®
ST-20
™
Flush
Страница 1: ...AC Refrigeration Flush Honeywell Genetron ST 20 Flush ...
Страница 2: ...mmon seals and gasket materials 0 0 10 0 20 0 30 0 40 0 50 0 60 0 RX11 ST 20 RX11 ST 20 Residue left 0 0 10 0 20 0 30 0 40 0 50 0 60 0 70 0 80 0 90 0 100 0 RX11 ST 20 RX11 ST 20 Oil Removed 2 minutes 20 psig N2 5 minutes 100 psig N2 A flushing agent with excellent solvency for mineral and new generation refrigerant oils Saves you time offers faster cycle times than other flushing agents Made with ...
Страница 3: ...they are purged from the system Purged material may include acids oil and particulate debris which must be disposed of properly 8 Connect the flush can valve as shown in Figure 1 and 2 or use a valve capable of connecting to 7 16 28 thread These valves are currently offered for sale at most refrigeration and air conditioning wholesalers 9 Connect the refrigeration service hose or refrigeration man...
Страница 4: ... safety goggles and nitrile gloves 4 Do not attempt to push ST 20 Flush through compressor bodies 3 It will be necessary to cut the refrigeration or air conditioning system at several points to isolate large components such as receivers and condensers which must be cleaned separately It may be impractical to clean large components with ST 20 Flush Inspect these components and consider mechanical c...