5 - 1
5
Data Formatting
Data Format Editor Introduction
You may use the Data Format Editor to change the scanner’s output. For example, you can use the Data Format Editor to insert
characters at certain points in bar code data as it is scanned. The selections in the following pages are used only if you wish to
alter the output.
Default Data Format setting = None.
Normally, when you scan a bar code, it is output automatically. However, when you create a format, you must use a “send” com-
mand (see
on page 5-3) within the format program to output data.
Multiple formats may be programmed into the scanner. They are stacked in the order in which they are entered. However, the
following list presents the order in which formats are applied:
1. Specific Terminal ID, Actual Code ID, Actual Length
2. Specific Terminal ID, Actual Code ID, Universal Length
3. Specific Terminal ID, Universal Code ID, Actual Length
4. Specific Terminal ID, Universal Code ID, Universal Length
5. Universal Terminal ID, Actual Code ID, Actual Length
6. Universal Terminal ID, Actual Code ID, Universal Length
7. Universal Terminal ID, Universal Code ID, Actual Length
8. Universal Terminal ID, Universal Code ID, Universal Length
The maximum size of a data format configuration is 2000 bytes, which includes header information.
If you have changed data format settings, and wish to clear all formats and return to the factory defaults, scan the
Default Data
Format
code below.
Add a Data Format
Step 1.
Scan the
Enter Data Format
).
Step 2.
Select
Primary/Alternate Format
Determine if this will be your primary data format, or one of 3 alternate formats. This allows you to save a total of 4
different data formats. To program your primary format, scan
0
using the
inside the back cover of
this manual. If you are programming an alternate format, scan
1
,
2
, or
3
, depending on which alternate format you are
programming. (See "Primary/Alternate Data Formats" on page 5-12 for further information.)
Step 3. Terminal Type
Refer to
(page 5-3) and locate the Terminal ID number for your PC. Scan three numeric bar codes
on the inside back cover to program the scanner for your terminal ID (you must enter 3 digits). For example, scan
0 0
3
for an AT wedge.
Note: 099 indicates all terminal types.
Step 4. Code I.D.
beginning on page A-1, find the symbology to which you want to apply the data format. Locate
the Hex value for that symbology and scan the 2 digit hex value from the
this manual.
If you wish to create a data format for all symbologies, with the exception of some specific symbologies, refer to B8
(
).
If you are creating a data format for Batch Mode Quantity, use 35 for the Code I.D.
Note: 99 indicates all symbologies.
* Default Data Format
Содержание Genesis 7580G
Страница 1: ...Genesis 7580g Presentation Area Imager User s Guide ...
Страница 6: ......
Страница 14: ...viii ...
Страница 80: ...5 14 ...
Страница 130: ...6 50 ...
Страница 134: ...7 4 ...
Страница 176: ...11 22 ...
Страница 184: ...13 4 ...
Страница 199: ...Programming Chart 0 1 2 3 4 5 6 7 8 9 ...
Страница 200: ......
Страница 202: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com 7580 UG Rev C 7 14 ...