background image

9.

To re-assemble the keypad, connect the four way connector block onto the pins on the keypad
PCB. Attach the keypad front plate to the back plate by inserting the two clips on the top of the
keypad front plate into the two apertures at the top of the keypad back plate, then gently push the
bottom of the keypad front plate into the back plate until it snaps securely into place.

10.

Keypad part number CP037 has a volume control pot marked VOL at the bottom right-hand
corner of the pcb. To adjust the volume, open up the keypad cover and adjust the pot (+ or -).

NOTE:

 The keypad door can be re-orientated to allow opening from either the left or right hand sides.

However, it should be noted that fitting or removal of the door should only be done when the front
plate is detached from the back plate. Attempted removal or insertion, of the door, when the keypad
is assembled may cause damage to the keypad mouldings.

NOTE :

 

1

 Use of screws other than No. 6 Pan head may damage the keypad mouldings.

EN50131 Compliance

This product is suitable for use in systems designed to comply with PD6662:2004 and
prEN50131-1:2004

Security Grade - 3
Environmental Class - II

This product is suitable for use in systems designed to comply with EN50131-1:1997

Security Grade - 2
Environmental Class - II

Honeywell Security

2 Redwood Crescent
Peel Park Campus
East Kilbride
G74 5PA
UK

II1-0200 Rev 2.1

© Copyright Honeywell Security

Отзывы: