
87 |
P a g e
DOUBLE GLASS BOARD & LED LIGHT GUIDE
FAN BYPASS SWITCHES & LEDs
(***NUMBER OF FANS CAN CHANGE BASED ON MODEL SIZE***)
The dipswitches, in the “
DOUBLE GLASS FANS
” area of
the Double Glass Board, are used to determine what
fans will be monitored by the board, verifying all fans are
indeed working properly before allowing the fireplace
burner to start.
Turn the switch
ON
(UP) to bypass monitoring of fan
number of your choice, &
OFF
(DOWN) to begin to
monitor fan activity.
If no fan is present, set switch to on so it will bypass
the need to verify fan activity. The switches are
numbered to correlate with the LED lights they are associated with above.
The third, smaller, dip switch panel
is the “Master Bypass” option.
Flipping these on bypasses all checks to the fan
system & Power Vent.
FAN LED INDICATORS
A.
Red
- Fan is not connected or malfunctioning
B.
Off - Fan is being bypassed
C.
Green
- Fan is running properly
POWER LED INDICATOR
The
Red
Power
LED lets you know the board is receiving power.
POWER VENT LED INDICATOR
The
Blue
Power Vent
LED lets you know the Power Power-Vent is properly sending & receiving signal to the board.
FAN & POWER VENT REQUEST LED
The
White
LED indicates the board is set for Honeywell system use