background image

 

 

 

    

 

 
 

 
 

ON

OFF

ARMED

READY

A

B

C

D

6

4

7

BYPASS

9

CHIME

#

3

STAY

5

TEST

8

CODE

0

2

AWAY

1

OFF

MAX

INSTANT

READY

FA260

R

ARMED

READY

FA 5 6 0

6

4

7

BYPASS

9

CHIME

#

3

STAY

5

TEST

8

CODE

0

2

AWAY

1

OFF

MAX

INSTANT

READY

R

AWAY

STAY

PAGE

 

 
 

U

ser 

G

uide 

 

 

 

 

K0736-1V2   10/04   Rev. A

 

FA130CP

FA130CP

FA130CP

FA130CP / FA130CPSIA

 / FA130CPSIA

 / FA130CPSIA

 / FA130CPSIA

S

S

e

e

c

c

u

u

r

r

i

i

t

t

y

y

 

 

S

S

y

y

s

s

t

t

e

e

m

m

s

s

Содержание First Alert FA130CP

Страница 1: ... INSTANT READY FA260 R ARMED READY FA560 6 4 7 BYPASS 9CHIME 3STAY 5TEST 8CODE 0 2AWAY 1OFF MAX INSTANT READY R AWAY STAY PAGE User Guide K0736 1V2 10 04 Rev A FA130CP FA130CP FA130CP FA130CP FA130CPSIA FA130CPSIA FA130CPSIA FA130CPSIA S Se ec cu ur ri it ty y S Sy ys st te em ms s ...

Страница 2: ...ual SYSTEM COMPATIBILITY NOTICE Your Honeywell security system is designed for use with devices manufactured or approved by Honeywell for use with your security system Your Honeywell security system is not designed for use with any device that may be attached to your security system s keypad or other communicating bus if Honeywell has not approved such device for use with your security system Use ...

Страница 3: ...n 15 Night Stay Mode Arms Perimeter Only Plus Selected Zones 15 Instant Mode Arms Perimeter Only Entry Delay Off 15 Away Mode Arms Entire System Entry Delay On 15 Maximum Mode Arms Entire System Entry Delay Off 15 Arming Commands 16 Single Button Arming 17 Step Arming Feature 17 Using the Keyswitch 18 Using the Keyswitch 18 Disarming and Silencing Alarms 19 Using the OFF key 19 Bypassing Protectio...

Страница 4: ...des 30 Authority Level Definitions 30 How to Assign User Codes and Attributes 31 Scheduling 32 About Scheduling 32 Creating Schedules 32 Event Logging Procedures 34 About Event Logging 34 Viewing the Event Log 34 Table of Event Log Codes 35 Testing the System To Be Conducted Weekly 36 About Testing the System 36 Trouble Conditions 37 Maintaining Your System 40 Fire Alarm System If Installed 41 Qui...

Страница 5: ...burglary protection Stay Night Stay Away Instant Maximum STAY arms perimeter zones only and entry delay is on INSTANT same as STAY except entry delay is off NIGHT STAY arms perimeter zones and selected interior zones entry delay on AWAY arms perimeter and all interior zones entry delay is on MAXIMUM same as AWAY except entry delay is off You can BYPASS selected zones while leaving the rest of the ...

Страница 6: ...d external sounders will sound and the keypad will display the zone s causing the alarm If your system is connected to a Central Monitoring Station an alarm message will also be sent To stop the alarm sounding simply disarm the system Memory of Alarm When an alarm condition occurs the keypad displays the number s of the zone s that caused the problem and displays the type of alarm e g fire The mes...

Страница 7: ...sage remains in the keypad s memory until a new message is recorded The volume control of the message is adjustable Refer to the procedures below when using the Message Center functions FA560VKP 004 V0 VOLUME KEY VOICE KEY FUNCTION KEY STATUS KEY DOWN VOLUME PLAY KEY AND UP VOLUME RECORD KEY MICROPHONE A B C D 6 4 7 BYPASS 9CHIME 3STAY 5TEST 8CODE 0 2AWAY 1OFF MAX READY INSTANT RECORD STATUS ARMED...

Страница 8: ...T THE POLICE from a nearby safe location Your keypads are functionally the same but may have different types of displays depending on the type installed with your system Alpha Display 2 line alpha display keypads feature a 2 line 32 character alphanumeric LCD which can display system messages in friendly English These keypads can also be programmed with custom zone descriptors Fixed Word Display F...

Страница 9: ...ower is present CHIME Appears when the CHIME feature is activated BAT Low battery condition in a wireless sensor if zone number displayed or low system battery if no zone number displayed ALARM Appears when an intrusion has been detected and the system is armed also appears during a fire alarm or audible emergency alarm Accompanied by the protection zone in alarm CHECK Appears when a malfunction i...

Страница 10: ...sarmed Refer to Testing The System section for test procedures 6 BYPASS Removes individual protection zones from being monitored by the system On Voice keypads used in conjunction with the FUNCTION and VOLUME keys to lower the message and voice system status volume 7 INSTANT Arms in manner similar to the STAY mode but without the entry delay feature 8 CODE Used to assign additional user codes and ...

Страница 11: ...odes and commands sequential key depressions must be made within 4 5 seconds of one another If 4 5 seconds elapse without a key depression the entry will be aborted and must be repeated from its beginning Be sure to observe this precaution when performing any of the procedures in this manual If you make a mistake while entering a security code stop press the key and then start over If you stop in ...

Страница 12: ...g to disarm the system and then re arm it again In addition when the system is armed AWAY reopening and closing the entry exit door before exit delay time expires e g reentering to get a forgotten item will reset the exit delay time once Entry Delay Entry Delays give you time to disarm the system when you re enter through the designated entrance door There are two entry delays if programmed The fi...

Страница 13: ...ed for this feature to minimize false alarms sent to the Central Monitoring Station Ask your installer if Exit Alarm is active in your system If so check this box FA130CPSIA The Exit Error condition works the same as described above except that in addition to the EXIT ALARM message a zone alarm message is also sent to the Central Monitoring Station In addition if an entry exit door or interior zon...

Страница 14: ...s desired Alpha Display DISARMED PRESS TO SHOW FAULTS Fixed Word Display Zone no and NOT READY Voice Status Voice Keypads if installed can announce system status and faulted zones up to 3 zone descriptors if the Voice Status feature is turned on To turn the Voice Status feature on off 0 2 4 also turns on Voice Chime mode see Chime mode section To announce Status Press FUNCTION 0 VOICE STATUS key A...

Страница 15: ...cted interior zones are armed and cause an alarm if anyone enters those areas e g waking in the middle of the night To avoid sounding an alarm you must disarm the system before any activity takes place in those interior zones Instant Mode Arms Perimeter Only Entry Delay Off Used when staying inside and do not expect anyone to use an entry exit door Arms same as Stay mode An alarm sounds immediatel...

Страница 16: ...seconds of the exit delay to warn you that it is ending Maximum security code 4 MAXIMUM same as Away described above Note that entry delay is turned off Arming Ding In addition to the keypad beeps the external sounder emits a short ding sound after arming if programmed to do so The ding confirms that the system is armed and may occur immediately after the command or be delayed until arm disarm rep...

Страница 17: ... 1 Press and hold the assigned function key for 2 seconds no code is required Function keys are shown below Alpha Display DISARMED READY TO ARM Fixed Word Display READY 2 The keypad begins beeping and displays the armed message The red ARMED indicator also lights Alpha Display ARMED AWAY YOU MAY EXIT NOW Fixed Word Display AWAY Step Arming Feature Single Button Step arming may have been programmed...

Страница 18: ...See your installer for the meanings of the lit red light Lit Steady system armed AWAY or system armed STAY and exit delay has expired Flashing system armed STAY and exit delay timer active Rapid flashing an alarm has occurred memory of alarm Before arming close all perimeter doors and windows To arm in the AWAY mode Turn the key to the right for 1 2 second and release Keypads beep twice and the re...

Страница 19: ... the system is disarmed NOTE If entry delay has started you ve opened the entry door you do not need to press the OFF key simply enter your security code The system will disarm in about 10 seconds after the last digit of the code is entered Alpha Display DISARMED READY TO ARM Fixed Word Display READY 2 To Silence a Burglary Alarm and Clear a Memory of Alarm Enter your security code This disarms th...

Страница 20: ...not allow fire zones to be bypassed Zones are automatically unbypassed when the system is disarmed 1 6 zone numbers see below Security Code BYPASS Enter the 2 digit zone number s for the zone s to be bypassed e g 06 10 13 etc Single digit zone numbers must be preceded by a zero e g 05 06 Alpha Display DISARMED PRESS TO SHOW FAULTS Fixed Word Display NOT READY 2 When finished the keypad will moment...

Страница 21: ... a few moments all open zones will be displayed and automatically bypassed Make sure that only those zones that you wish to leave unprotected are bypassed and that there are no other zones unintentionally left open Alpha Display DISARMED PRESS TO SHOW FAULTS Fixed Word Display NOT READY 2 Wait for all bypassed zones to be displayed then arm the system as desired Ask your installer if Quick Bypass ...

Страница 22: ...on off system must be disarmed 9 Security Code CHIME The CHIME message appears when on Perimeter zones will cause a tone when faulted DISARMED CHIME READY TO ARM Fixed Word Display CHIME The CHIME message disappears when Chime mode is off Voice Chime You can set the Voice Keypads if installed to announce faulted opened entry exit or perimeter zones whenever normal Chime mode is on To turn Voice Ch...

Страница 23: ...ark in the box beneath that key Setting the Date and Time You can set the time and date by doing the following 1 6 3 Security Code Alpha Display DISARMED READY TO ARM 2 Press when the time date is displayed A cursor appears under the first digit of the hour To move cursor ahead press To go back press Enter the 2 digit hour setting Enter the 2 digit minute setting Press 1 for PM or 0 for AM Enter t...

Страница 24: ...ctivate a Panic Function Press and hold down for at least 2 seconds whichever lettered key on the keypad has been programmed for the desired emergency function OR Press both keys of the assigned key pair at the same time Alpha Display DISARMED READY TO ARM Fixed Word Display READY Typical Panic Alpha Display ALARM 99 Fixed Word Display 99 and ALARM 560KP 10 001 V0 ARMED READY FA 5 6 0 6 4 7 BYPASS...

Страница 25: ...st activate the desired function key before macros can be assigned See the chart at the back of this manual for the key s assigned for macros 1 6 6 Security Code Alpha Displays DISARMED READY TO ARM If a macro has been previously defined the keystrokes are shown on the bottom line of the display otherwise the display is blank To exit this mode and keep the existing macro definition press any key e...

Страница 26: ...security system in the AWAY mode The procedures in the table that follows show you how you would program this macro Function Keystrokes Required Keypad Display 1 Bypass zones 02 03 Press BYPASS 6 key then 2 digit zone numbers 02 03 6 0 2 0 3 2 Insert terminator Press the D key for at least 2 seconds 6 0 2 0 3 F 3 Turn light on device 01 Press and 7 keys for device ON and 01 key for selecting devic...

Страница 27: ... be manually turned on or off using the commands described below See your installer for a list of devices that may be set up for your system A list of these devices is provided at the back of this manual for you to fill out To Activate Devices 7 2 digit device number Security Code Devices associated with that device number activate To Deactivate Devices 8 2 digit device number Security Code Device...

Страница 28: ...y wish to have sent to the pager The pager display format is as follows 3 digit Event Code È È È È Optional 16 digits Æ Æ Æ Æ AAAAAAAAAAAAAAAA BBB CCCC Å Å Å Å 1 digit partition 3 digit User or Zone No A B C Optional 16 digits for Account numbers PIN numbers or any other data programmed by the installer if required A 3 digit code that describes the event that has occurred in your system see for ev...

Страница 29: ...econds Press and hold the programmed Paging Key for at least 2 seconds wait for beep 2 The recipient on seeing the 999 9999 message will understand the prearranged meaning of this signal Alpha Display DISARMED READY TO ARM Fixed Word Display READY 999 9999 Pager Display Latch Key Paging You can program a schedule that causes a pager report to be sent if the system is not DISARMED by the scheduled ...

Страница 30: ... situations Therefore the only step you usually need to do when adding users is assign a user number and a security code Authority Level Definitions Authority levels define the system functions a particular user can cannot perform Level Title Explanation N A System Master Reserved for user 02 Can perform all system functions and assign codes can change its own code as described on the following pa...

Страница 31: ...ing any associated RF keys are erased from the system Authority Level System Master code 8 user no 1 auth level Factory Assignments Authority Levels see definitions on previous page users 03 16 0 0 standard user 2 guest 1 arm only 3 duress Access Group System Master Code 8 user no 2 group 1 8 Factory Assignments none You can assign users to a group then set an access schedule that defines the time...

Страница 32: ...section for a list of output device numbers used in your system 02 set a user access schedule for one or more users see Security Codes section for an explanation of access groups 03 send a latch key report to a pager if the system is not disarmed by a specified time message sent is 777 7777 04 automatically arm the system in STAY mode at a specified time 05 automatically arm the system in AWAY mod...

Страница 33: ...9 Enter the desired repeat option 0 no repeat 1 repeat schedule weekly 2 repeat schedule biweekly every other week 3 repeat schedule every third week 4 repeat schedule every fourth week e g To make a schedule that happens everyday you would select all days with a repeat count of 1 To make a schedule that runs for one week then stops select everyday with a repeat count of 0 REPEAT OPTION 0 4 X 10 F...

Страница 34: ...logging of any new event Viewing the Event Log 1 6 0 Master Code Alpha Displays DISARMED READY TO ARM 2 The system displays the most recent event as follows event number type of event identified by its corresponding code see your installer for the meaning of each code zone or user number depending on type of event time and date of the event s occurrence 3 Pressing displays previous events back in ...

Страница 35: ...ble Expansion Mod Supervision 341 Trouble ECP Cover Tamper 344 RF Receiver Jam 351 Telco Line Fault 353 Long Range Radio Trouble 373 Fire Loop Trouble 374 Exit Error Alarm 380 Global Trouble Trouble Day Night Code Definition 381 RF Supervision Trouble 382 Supervision Auxiliary Wire Zone 383 RF Sensor Tamper 384 RF Sensor Low battery 393 Clean Me 401 Disarmed Armed AWAY Armed STAY 403 Schedule Arm ...

Страница 36: ...ee beeps from the keypad Identification zone number or zone description of each faulted protection point should appear on the display The display clears when the door or window is closed 5 Walk in front of any interior motion detectors if used and listen for three beeps The identification of the detector should appear on the display when it is activated The display clears when no motion is detecte...

Страница 37: ...e If the display persists CALL FOR SERVICE Note A display of CHECK 70 on Alpha Display keypads indicates that the wiring connection to the external sounder is at fault opened or shorted and you should CALL FOR SERVICE See BELL FAILURE on next page A display of CHECK 90 indicates that RF interference may be impeding the operation of wireless sensors in the system See Rcvr Jam on next page 2 If ther...

Страница 38: ...mitter or BAT with number displayed 00 is RF keypad zone No Accompanied by a single beep about once every 40 seconds at the keypad Either replace the battery yourself or CALL FOR SERVICE If the battery is not replaced within 30 days a CHECK display may occur Rcvr Jam Wireless part of the system is experiencing or CHECK 90 RF interference which may impede reception from wireless sensors ALARM 1xx F...

Страница 39: ...r from AC and back up battery for the system has stopped and the system is inoperative CALL FOR SERVICE In The Event Of Telephone Operational Problems In the event of telephone operational problems disconnect the control from the phone line by removing the plug from the phone wall jack We recommend that your installer demonstrate this disconnection on installation of the system Do not attempt to d...

Страница 40: ...ransmitter and the portable wireless keypad and displays a low battery message A low battery in a portable wireless keypad is detected as soon as one of its keys is pressed and displayed as 00 Battery operated smoke detectors with a low battery also emit a single chirp sound approximately once every 20 30 seconds Alkaline batteries provide a minimum of 1 year of operation and in most units and app...

Страница 41: ...learing Memory of Alarm 1 You can silence the alarm at any time by pressing the OFF key the security code is not needed to silence fire alarms To clear the display enter your code and press the OFF key again to clear Memory of Alarm 2 If the Keypad s FIRE display does not clear after the second OFF sequence smoke detectors may still be responding to smoke or heat producing objects in their vicinit...

Страница 42: ...and notify your local Fire Department immediately 4 If no flames or smoke are apparent investigate the cause of the alarm The zone number s of the zone s in an alarm condition will be displayed at the keypad Using the Panic Key s Assigned for FIRE Emergency A key or key pair may have been assigned for manually initiating a FIRE alarm See the Panic Keys section for key assignments For convenience i...

Страница 43: ...fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows A smoke detector installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit including basements and excluding crawl spaces and unfinished attics In addition the NFPA recommends that ...

Страница 44: ... the ground 3 Sketch a floor plan of the building Show windows doors stairs and rooftops that can be used to escape Indicate escape routes for each room Keep these routes free from obstruction and post copies of the escape routes in every room 4 Assure that all bedroom doors are shut while you are asleep This will prevent deadly smoke from entering while you escape 5 Try the door If the door is ho...

Страница 45: ...unders Memory of alarm remains until cleared Clear Alarm Memory After disarming enter code again Press OFF key again Keypad beeps rapidly on entry if alarm has occurred while absent Alarm display will remain upon disarming until cleared Duress if active and connected to Central Station Arm or disarm normally but use your 4 digit Duress code to do so Performs desired action and sends silent alarm t...

Страница 46: ...TOARM WITHIN 10 MINUTES a Opened zone numbers will appear b BAT displayed with zone number of transmitter c No special display TWO SHORT BEEPS Keypad only ARM AWAY or MAXIMUM AWAY is displayed Red ARMED indicator is lit THREE SHORT BEEPS Keypad only a ARM STAY NIGHT STAY OR INSTANT b ZONE OPENED WITH SYSTEM IN CHIME MODE a STAY or INSTANT is displayed Red ARMED indicator is lit b CHIME displayed z...

Страница 47: ...ened Zone identifications will appear b LO BAT displayed with description of transmitter c No special display TWO SHORT BEEPS Keypad only ARM AWAY or MAXIMUM ARMED AWAY or MAXIMUM displayed Red ARMED indicator lit THREE SHORT BEEPS Keypad only a ARM STAY NIGHT STAY OR INSTANT b ZONE OPENED WHILE SYSTEM IS DISARMED a ARMED STAY or ARMED INSTANT displayed Red ARMED indicator lit b CHIME displayed de...

Страница 48: ...s should not attempt to make such connections themselves but should contact appropriate electric inspection authority or electrician as appropriate Ringer Equivalence Number Notice The Ringer Equivalence Number REN assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface The termination on an interface may consist o...

Страница 49: ...tures Comments Exit Delay Entry Delay 1 Entry Delay 2 Night Stay Zones Zones Quick Arm yes no Quick Bypass yes no Automatic Paging yes no users Keyswitch Arming circle type of LED lighting Arm AWAY steady flash Arm STAY steady flash Function Keys Function Keys A B C D Comments Single Button Arming Step Arming Paging see Paging chart Time Date Display Macro Key Emergency Key Personal Emergency Key ...

Страница 50: ...ng 0 no paging 1 arm only 1 allow paging 2 guest 3 duress Paging Setup Automatically Reports Upon Pager Phone Number Prefix Characters open close alarm trouble zone list Sched Func Key Pager Schedules master code 6 4 No Event Device No Group No Start Stop Repeat Random see list below for 01 events for 02 events Time Day Time Day 0 4 yes no see device list below enter 1 8 01 Events 00 clear event 0...

Страница 51: ... 51 Notes ...

Страница 52: ... 52 Notes ...

Страница 53: ...Address Insurance Company Policy No FA130CP FA130CPSIA___________________________Other Type of Alarm Burglary Fire Both Installed by Serviced by Name Name Address Address B NOTIFIES Insert B Burglary F Fire Local Sounding Device Police Dept Fire Dept Central Station Name Address Phone C POWERED BY A C With Rechargeable Power Supply D TESTING Quarterly Monthly Weekly Other continued on other side ...

Страница 54: ... Attic Basement Living Room Dining Room Hall F BURGLARY DETECTING DEVICE LOCATIONS Front Door Basement Door Rear Door All Exterior Doors 1 st Floor Windows All windows Interior locations All Accessible Openings Including Skylights Air Conditioners and Vents G ADDITIONAL PERTINENT INFORMATION Signature Date ...

Страница 55: ...o prevent injury or death Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation manual Passive Infrared Detectors do not provide volumetric area protection They do create multiple beams of protection and intrusion can only be detected in unobstructed areas covered by those beams They cannot detect motion or intrusion that takes p...

Страница 56: ...AMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Some states do not allow limitation on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Seller...

Отзывы: