PROCESS INFORMATION DISPLAYS
6510020335
134
6.7.2
Scanner Status Information
The scanner status information section lists the scanners and the current status of the
scanner. If the scanner is in single point mode or fixed-point mode, the scanner head
position is also displayed.
Fig. 116.
Scanner Sensor Status Information
The units of the single point position are displayed along with the value. The default unit
measurement is bins. The head position units are configured on the profile setup display.
Scanner Status Modes
•
Measurement (Scanning) : Scanner is scanning in normal operating mode
measuring production data. The scanner remains in this mode while performing a
scanning mode background or standardize.
•
Measurement (Single Point): Scanner is at single point measuring in production
data.
•
Measurement (Fixed Point): Scanner is at fixed point measuring in production data.
•
Maintenance (Scan test): Scanner is in maintenance mode performing a scanner
test.
•
Maintenance (Building Profile Correction): Scanner is in maintenance mode
performing a profile correction operation.
•
Maintenance (Stability): Scanner is in maintenance mode performing a stability
operation on a sensor.
•
Maintenance (Background): Scanner is in maintenance mode performing a
background operation on a sensor.
•
Maintenance (Reference): Scanner is in maintenance mode performing a reference
operation on a sensor.
•
Maintenance (Sample): Scanner is in maintenance mode performing a sample
operation on a sensor.
•
Offsheet: Scanner is in offsheet and available for operation.
•
Offline (Unavailable): Scanner is in offsheet and is unavailable for operation.
Содержание Experion MX
Страница 1: ...Experion MX RELEASE 702 1 Operators Guide 6510020335 Rev 02 May 2019 ...
Страница 7: ...6510020335 7 8 NOTICES 168 ...
Страница 20: ...SCANNER SAFETY AND LOCAL CONTROLS 6510020335 20 Fig 15 Cable End Voltage Zones ...
Страница 21: ...SCANNER SAFETY AND LOCAL CONTROLS 6510020335 21 Fig 16 Distant End Voltage Zones ...
Страница 124: ...PROCESS INFORMATION DISPLAYS 6510020335 124 Fig 105 Profile Display ...
Страница 159: ...PROCESS INFORMATION DISPLAYS 6510020335 159 Fig 148 Precision Platform 4000 01 Scanner ...
Страница 160: ...PROCESS INFORMATION DISPLAYS 6510020335 160 Fig 149 Precision Platform 4000 20 21 Scanner ...