background image

TEMPLATE

TEMPLATE

® U.S. Registered Trademark
Copyright © 2000 Honeywell   •   All Rights Reserved

INSTALLATION INSTRUCTIONS

HE265A,B

Bypass Flow-Through Humidifier

READ AND SAVE THESE INSTRUCTIONS

APPLICATION

The Enviracaire Elite™ HE265A,B Bypass Flow-Through Humidifier uses
the warm air furnace blower to provide humidification for the whole house.
The HE265A,B works with virtually any Honeywell humidity control, but for
optimal performance, use with the Honeywell Perfect Climate Comfort
Center™ control.

INSTALLATION

WARNING

Hazardous Voltage.
Can cause Personal Injury or Equipment Damage.
Do not cut or drill into any air conditioning or electrical accessory.

CAUTION

Freezing Water and High Water or Static Pressure Hazard.
Can cause water damage or permanent equipment damage.

The humidifier must be located where the ambient temperature
is above 32

°

F (0

°

C) and below 160

°

F (71

°

C).

Be sure supply plenum static pressure is no greater than 0.3 in.
w.c. and water pressure is no greater than 125 psi.

IMPORTANT

To assure optimal product performance, be sure the template is
level before marking.

1. Determine the best location for the humidifier and draw a level line

on the plenum. See Fig. 1.

IMPORTANT

Mount the humidifier at least 3 in. (76 mm) above the furnace
jacket to allow adequate space for the solenoid valve and drain
line. Check that there is adequate space above the humidifier to
remove and install the humidifier cover. Do not install on a
furnace jacket.

M12248B

HORIZONTAL

DOWN

FLO

LOWBOY

HIG

HB

OY

Fig. 1. Typical humidifier installation locations.

2. Tape this piece of paper in position as your template and trace

around the template.

3. Remove the template and carefully cut the rectangular opening.
4. Disassemble the humidifier; remove the cover and take out the

humidifier pad assembly. See Fig. 2.

NOTE:

Sidewalls are interchangeable for either left or right
bypass installation. To change direction, remove the screws
holding each sidewall, switch sidewall locations and reinstall
the screws.

5. Position the humidifier housing in the opening (be sure it is level), so

the locking tabs are in place on the lower sheet metal edge of the
opening.

6. Secure the humidifier housing to the opening at the top and bottom

using sheet metal screws.

Fig. 2. Humidifier components.

7. Locate the other plenum and cut an opening for a 6 in. (152 mm)

collar.

8. Install the 6 in. (152 mm) collar.

NOTE:

Be sure to install a duct damper for summer shutoff on
systems with air conditioning.

9. Install a 6 in. (152 mm) diameter duct from the collar to the

humidifier.

NOTE:

Some installations require a 90

°

 elbow attachment to the

collar.

TEMPLATE

69-1424EF

  M14672

WATER
FEED NOZZLE

FRAME

HUMIDIFIER
HOUSING

WATER
FEED TUBE

HUMIDIFIER
PAD ASSEMBLY

COVER

SIDEWALL

BY-PASS SIDEWALL

Содержание enviracaire Elite HE265A

Страница 1: ...dequate space for the solenoid valve and drain line Check that there is adequate space above the humidifier to remove and install the humidifier cover Do not install on a furnace jacket M12248B HORIZONTAL DOWN FLO LOWBOY HIGHBOY Fig 1 Typical humidifier installation locations 2 Tape this piece of paper in position as your template and trace around the template 3 Remove the template and carefully c...

Страница 2: ...r cold water either hard or softened can be used in the humidifier 1 Use the self piercing saddle valve included to tap into the water supply line at an appropriate location CAUTION Chemical Hazard Can cause personal injury or equipment damage Do not use any line connected to an air conditioner IMPORTANT The saddle valve is not designed to regulate water flow The valve is either open or closed To ...

Страница 3: ...ptimal de l appareil 1 Déterminer l endroit le mieux approprié pour l humidificateur et tracer une ligne de niveau sur le plenum Voir la Fig 1 M12248B HORIZONTAL DOWN FLO LOWBOY HIGHBOY Fig 1 Emplacements types de l humidificateur IMPORTANT Installer l humidificateur à une distance minimale de 76 mm 3 po au dessus du boîtier de l appareil de chauffage afin de laisser un espace suffisant pour le mo...

Страница 4: ...ur à ailette REMARQUE Certains modèles de ventilateurs ont des prises pour humidificateurs Si tel est le cas il n est pas nécessaire d installer un relais de détection de courant ou un interrupteur à ailette TUYAUTERIE DU ROBINET VANNE À ÉTRIER L humidificateur fonctionne avec de l eau dure ou de l eau douce L eau peut être chaude ou froide 1 Utiliser le robinet vanne à étrier autoperceur fourni p...

Отзывы: