9.3.1 Archive content
Pos. Address Display
Description
Retrievable
1
01:01F8 GONo
Global Block number
S
2
01:0A20 ABNo
Archive Block number
A + S
3
01:0400 Time
Date and time
A + S
4
02:0300 Vb
Volume at base conditions
A + S
5
02:0302 VbT
Volume at base conditions total
A + S
6
03:0161 VbMP
↑
Maximum VbMP of last month
A + S
7
03:0165 Time
Date and time of Vb.MP
A + S
8
03:0169 Stat
Status of Vb.MP
A + S
9
04:0161 VbDy
↑
Maximum VbDy of last month
A + S
10
04:0165 Time
Date and time of VbDy
A + S
11
04:0169 Stat
Status of VbDy
A + S
12
04:0300 Vm
Volume at measurement conditions
A + S
13
04:0302 VmT
Volume at measurement conditions total
2
A + S
14
10:0161 VmMP
↑
Maximum VmMP of last month
A + S
15
10:0165 Time
Date and time of VmMP
A + S
16
10:0169 Stat
Status of VmMP
A + S
17
11:0161 VmDy
↑
Maximum VmDy of last month
A + S
18
11:0165 Time
Date and time of VmDy
A + S
19
11:0169 Stat
Status of VmDy
A + S
20
02:0110 St.2
Instance-Status 2 (incl. Vn)
A + S
21
04:0110 St.4
Instance -Status 4 (incl. Vb)
A + S
22 03:0A23 ErReg
Error register
A
23 01:0A21 Check
Check sum result ( „CRC OK“ or „Error“)
A + S
The values can be retrieved in accordance with the information in the table via D = display and/or
I = interface.
When using an encoder then the original operating volume "Vo" (01 240) can also be set.