TBL TBL T
T NO
EOL
C
V-
NC
V+
13
2
TEST
50%
100%
75%
25%
❶
Select the mounting location.
❹
Wire the unit.
❸
Mount the unit.
❺
a
Walk-test the sensor.
Mounting Location Guidelines
• 2.3 m (7’6”) mounting height
• Avoid direct or reflected sunlight
• Aim sensor away from windows or heating/
cooling devices
• Sensor must have a clear line-of-sight to
protected area
• Use a small screwdriver to unfasten the housing
latch. Gently pull apart the housings.
• Push outward on the PCB latch and lift the PCB
out of the housing.
• Slide the wire through the wire channel in the
back housing.
• Mount the back housing flat against a wall or in a
corner.
• Replace the PCB.
• Connect wires as shown using 0.3 - 1.0 mm
2
(18 to 22 gauge) wire size. Observe proper
polarity.
• Use Switch 3 to select the appropriate fluorescent
light filter (see Dip Switch Settings chart on the next
page).
• Apply power to the unit. Initialization is complete
when the LED stops flashing slowly.
• Adjust the microwave range to minimum setting
(25%) by turning the range adjustment counterclock-
wise using a small screwdriver.
• Replace the front housing.
• Begin walking through the detection area.
- The LED will turn red, indicating an alarm detection.
• Increase the microwave range as necessary.
• Repeat the items in step 5a until proper detection
range is obtained.
❺
b
Optional: Walk-test using Zone Finder
Corner
Mount
Wire Channel
Wall Mount
75%
100%
25%
50%
DT
-7450/7450C DU
AL TEC
®
Motion Sensor Installation Instructions
Use the Zone Finder mode to identify the PIR and/or
microwave pattern. In Zone Finder mode the red
LED is disabled.
❷
Separate the sensor housings and
remove the printed circuit board (PCB).
V+
V-
NC
C
Alarm
125 mA
25 VDC
Power
35 mA
7.5-16 VDC
(For UL 8.0-16 VDC)
NO
T
T
Tamper
50 mA
24 VDC
EOL
DT-7450
DT-7450C
• Apply a screwdriver for five seconds to short the
test pads.
• During the Zone Finder walk-test mode, the LED
turns:
- green for one second for every PIR detection;
- yellow for two seconds for every microwave
detection.
• Adjust the microwave range as necessary.