Honeywell DT7235T Скачать руководство пользователя страница 1

DT -7235/DT

-7235T  DUAL TEC

®

 Motion Sensor Installation Instructions

TT

Step 1

Separate the sensor housings and remove

Printed Circuit Board (PCB).

Use a small screwdriver to unfasten the hous-

ing latch and separate the sensor housings.

P

ush outward on the PCB latch to lift the PCB

out of the housing.

Step 3

W

ire the sensor

.

Observing the proper polarity

, wire the unit as

sh

own in the illustration below

, use 1.02 to 0.64 mm

(18 to 22 A

WG) wire.

Step 2

Mount the sensor

.

Break out the mounting/wiring knockouts and

mount the sensor in an appropriate location.

An ideal location meets the following objectives:

Allows a clear line-of

-sight to all areas to

protect.

D

oes not directly face windows.

A

voids close proximity to moving machinery

,

fluorescent lights, and heating/cooling

sources.

See Special Instructions for installations

containing pets.

NOTE:

  maximum range is obtained at a

mounting height of 2.3 m (7’6”).

Knockout

Housing

latch

PCB latch

FRONT HOUSING

REAR HOUSING AND PCB

Terminal Block (TB1)

PCB

LED

(DS1)

LED Enable

(Cut or remove

LED enable jumper

J1* to disable LED)

Alarm

500 mA

30 VDC

Power

25 mA

7.5-16 VDC

(UL: 8.9-14.5 VDC)

Step 4

W

alk

-test the sensor

.

After returning the PCB to the rear hous-

ing, reassemble the sensor housing. Ap-

ply power to the sensor and begin walk

-

test when the red LED is off

.

W

alk across the detection area at the

ranges to be covered. The red LED should

indicate an alarm condition after 2 to 4 nor

-

mal steps. When there is no motion in the

detection area the LED should be off

.

DT

-7235

TB1

TB2

DT

-7235T

Alarm

500 mA

30 VDC

Power

25 mA

7.5-16 VDC

(UL: 8.9-14.5 VDC)

TB1

DT

-7235T

Tamper

50 mA

24 VDC

TB2

Remove look

-down

mask for non-pet

applications.

* J1 may be located in either location

indicated in the above illustration.

Отзывы: