background image

 

56 

Product Service and Repair 

 

Honeywell International Inc. provides service for all its products through service 
centers throughout the world.  To obtain warranty or non-warranty service, 
contact the appropriate location below to obtain a Return Material Authorization 
number (RMA #) before returning the product. 

North America 

Telephone:  (800) 782-4263 

E-mail:  [email protected] 

Latin America 

Telephone:  (803) 835-8000  
Telephone:  (800) 782-4263  
Fax:  (239) 263-9689 

E-mail: [email protected] 

Brazil 

Telephone:  +55 (11) 5185-8222 
Fax:  +55 (11) 5185-8225 

E-mail:  [email protected] 

Mexico 

Telephone:  01-800-HONEYWELL (01-800-466-3993) 
Fax:  +52 (55) 5531-3672 

E-mail:  [email protected] 

Europe, Middle East, and Africa 

Telephone: +31 (0) 40 2901 633 
Fax:  +31 (0) 40 2901 631 

E-mail:  [email protected] 

Hong Kong 

Telephone:  +852-29536436 
Fax:  +852-2511-3557 

E-mail:  [email protected] 

Singapore 

Telephone:  +65-6842-7155 
Fax:  +65-6842-7166 

E-mail:  [email protected] 

China 

Telephone:  +86 800 828 2803 
Fax:  +86-512-6762-2560 

E-mail:  [email protected] 

Japan 

Telephone:  +81-3-6730-7344 
Fax:  +81-3-6730-7222 

E-mail:  [email protected] 

Online Product Service and Repair Assistance 

You can also access product service and repair assistance online at 

Содержание Dolphin 7600

Страница 1: ...Horizon 7600 Presentation Laser Imager Installation and User s Guide ...

Страница 2: ...rights reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of HII 2002 2011 Honeywell International Inc All rights reserved Web Address www honeywellaidc com Trademarks Metrologic and MetroSet2are trademarks or registered trademarks of Metrologic Instruments Inc or Honeywell International Inc Microsoft Windows 95 and...

Страница 3: ...ion 12 Keyboard Wedge 12 Stand Alone Keyboard 13 USB 14 RS232 or Light Pen 16 RS485 18 OCIA 19 Secondary Scanner 20 EAS 23 EAS Deactivation Antenna 23 Operation 24 Audible Indicators 24 Visual Indicators 25 Failure Modes 26 Changing the Beeper Tone Volume 27 Power Save Modes and IR Detection 28 Scan Volume Specifications 30 Depth of Field by Minimum Bar Code Element Width 31 Troubleshooting 32 Des...

Страница 4: ...ii Limited Warranty 50 Regulatory Compliance 52 Index 54 Customer Support 55 Technical Assistance 55 Product Service and Repair 56 ...

Страница 5: ... top plate Firmware updates via Flash ROM Field replaceable window EAS deactivation antenna is standard Supports commonly used interfaces including USB and Keyboard Wedge Custom Edit bar code data PowerLink user replaceable cables RS232 auxiliary port for adding peripherals Programmable depth of field OPOS and JPOS system compatible Sunrise 2005 Compliant Scanner Interface High Impact Plastic Top ...

Страница 6: ...n relief xxx specifies connection to the host Contact customer service for additional information 54 54002 Keyboard Wedge PowerLink Cable with Adapter Cable MVC Voltage Converter Cable 12VDC to 5 2VDC or 12VDC to 5 2VDC Contact a customer service representative for additional information on MVC cable series and the host connections available 54 54020 Stand Alone Keyboard Wedge PowerLink Cable 54 5...

Страница 7: ...erformance differences To change window type the scanner must be returned to the manufacturer for additional configuration 46 46602 Stainless Steel Top with Sapphire Window 46 46603 Stainless Steel Top with Everscan Window 46 46604 Stainless Steel Top with Standard Window 46 46605 High Impact Plastic Top with Sapphire Window 46 46606 High Impact Plastic Top with Everscan Window 46 46607 High Impac...

Страница 8: ...put Window Laser Aperture Amber LED Located Under Window Red LED Located Under Window Speaker Cable Connection Area Stainless Steel Top MS7625 units only Package Flow Indicator Arrow Head Rubber Connector Plug EAS Deactivation Antenna Connector ...

Страница 9: ...he output window will need occasional cleaning For the 7600 glass window 1 Spray glass cleaner onto lint free non abrasive cleaning cloth 2 Gently wipe the scanner window For the 7600 red window 3 Use mild soap and water with lint free non abrasive cleaning cloth 4 Gently wipe the scanner window ...

Страница 10: ...om of the unit The label contains information such as the model number date of manufacture serial number and caution information An additional caution label is located under the top plate The following are examples of these labels Figure 2 Label Locations ...

Страница 11: ...Only except RS485 Interface If the following label is attached to your product the product meets Korean agency approval for Class A equipment 이 기기는 업무용 A급 전자파적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며 가정외의 지역에서 사용하는 것을 목적으로 합니다 ...

Страница 12: ...straight up to remove There is no hardware required to remove or replace the top cover See caution on page 3 There are two installation tabs under the top cover that can be used to place the unit into the counter top mounting hole Figure 5 DO NOT PRESS on the window in the replacement Top plate Figure 6 DO NOT Turn the unit upside down Figure 3 ...

Страница 13: ...trim ring for support The trim ring PN 46 46641 is an optional purchase Contact customer service for details Before starting to mount the 7600 determine the direction of package flow for your application The unit must be mounted in the countertop with the small arrowhead on the top of the unit pointing in same direction as the package flow Figure 7 Package Flow Option A Shelf Support Figure 8 Spec...

Страница 14: ...10 Option B Free Hanging Support Figure 10 Package Flow right Figure 11 Specifications for Free Hanging Support Figure 12 Installation Tabs ...

Страница 15: ...11 Option C Trim Ring Figure 13 Counter Top Opening for Trim Ring PN 46 46641 Figure 14 Trim Ring PN 46 46641 Installation ...

Страница 16: ... 5 Connect the external power supply to the power jack on the PowerLink cable 6 Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet 7 Connect AC power to the transformer The outlet should be near the equipment and easily accessible 8 Scan the Load Keyboard Wedge Defaults bar code to configure the 7600 for Keyboard Wedge communication 9 Turn on the hos...

Страница 17: ...C outlet 7 Connect AC power to the transformer The outlet should be near the equipment and easily accessible 8 Scan the Load Keyboard Wedge Defaults bar code then the Enable Stand Alone Keyboard bar code to configure the 7600 for Stand Alone Keyboard communication Note When scanning the bar codes cover the code not being scanned to ensure the codes are read in the proper sequence 9 Turn on the hos...

Страница 18: ...op of the 7600 5 Connect the other end of the USB cable to the host Before continuing verify that the USB PowerLink cable is connected to the appropriate interface jack on the scanner An incorrect cable connection can cause communication problems or potential damage to the scanner Continued on next page Caution To maintain compliance with applicable standards all circuits connected to the scanner ...

Страница 19: ...rantee that scanned information will appear at the PC A software driver and correct configuration setting may also be required for proper communication to occur 6 Scan the Enable USB Defaults bar code to configure the 7600 for USB communication 7 Turn on the host system 9 9 9 9 7 8 E ...

Страница 20: ...wer Link Cable 5 Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet 6 Connect AC power to the transformer The outlet should be near the equipment and easily accessible 7 Scan the appropriate bar codes on page 17 to configure the 7600 for RS 232 or Light Pen communication 8 Turn on the host system Caution To maintain compliance with applicable standar...

Страница 21: ...or RS232 Communication Scan 1 st 9 9 9 9 9 8 Recall Defaults Scan 2 nd 4 1 5 5 5 4 Enable RS 232 For Light Pen Communication Scan 1 st 9 9 9 9 9 8 Recall Defaults Scan 2nd 4 1 5 5 2 4 Enable Light Pen Wand ...

Страница 22: ...ppear at the PC A software driver and correct configuration setting are also required for proper communication to occur 4 Turn on the host system 5 Scan the Load 46xx IBM Defaults bar code to configure the 7600 for RS485 communication For additional communication options for RS485 interfaces refer to the MetroSelect Programming Guide PN 00 02407 Caution To maintain compliance with applicable stand...

Страница 23: ...ppear at the PC A software driver and correct configuration setting are also required for proper communication to occur 4 Turn on the host system 5 Scan the Load OCIA Defaults bar code to configure the 7600 for OCIA communication For additional communication options for OCIA interfaces refer to the MetroSelect Programming Guide PN 00 02407 Caution To maintain compliance with applicable standards a...

Страница 24: ... the scanner An incorrect cable connection can cause communication problems or potential damage to the scanner 7 Insert the attached rubber plug into the remaining jack not being used on the 7600 8 Check the AC input requirements of both power supplies to make sure the voltage matches the AC outlets 9 Connect AC power to the transformers The outlets should be near the equipment and easily accessib...

Страница 25: ...a Honeywell scanner refer to Section O of the MetroSelect Configuration Guide 4 3 7 3 3 0 Enable Aux Port The auxiliary input port s data format must match the main output format of the secondary scanner 12 Scan the following bar codes in order to configure the secondary scanner to match the auxiliary port s data format 1 st Enable AUX Output 2 nd Secondary Scanner Data Format 1 2 4 8 1 7 4 3 7 5 ...

Страница 26: ...22 Figure 22 Connector Orientation Figure 23 Secondary Scanner Setup ...

Страница 27: ... unit does not scan out beyond the deactivation range Unit CheckPoint Recommended Switch Bank Settings 7600 Depth of Field Settings MS7620 1 2 3 4 5 on SW1 SW2 Fixed Low Density MS7625 1 2 3 4 5 on SW1 SW2 Fixed Low Density Note Minimum element width changes to 6 8 mil when in this mode Figure 24 EAS Cable and Connector Contact Checkpoint Systems directly for additional EAS support EAS Cable Conne...

Страница 28: ...ot beep once and the red light does not flash then the bar code has not been successfully read Razzberry Tone This is a failure indicator Refer to failure modes page 26 Three Beeps During Operation When placing the scanner in program mode the red LED will flash while the scanner simultaneously beeps three times The red and amber LEDs will continue to flash until the unit exits program mode Upon ex...

Страница 29: ...e scanner will beep once If the red LED does not flash or the scanner does not beep once then the bar code has not been successfully read Steady Amber and Steady Red After a successful scan the scanner transmits the data to the host device Some communication modes require that the host inform the scanner when data is ready to be received If the host is not ready to accept the information the scann...

Страница 30: ...ed a motor failure Return the unit for repair at an authorized service center Continuous Razzberry Tone with both LEDs off If upon power up the scanner emits a continuous razzberry tone then the scanner has an electronic failure Return the unit for repair at an authorized service center Three Beeps on power up If the scanner beeps 3 times on power up then the nonvolatile memory that holds the scan...

Страница 31: ...e 9 9 9 9 7 5 N Changing the Beeper Volume Volume levels may be programmed directly or incrementally using the following bar code The new volume will be heard followed by a short pause Two more tones will be heard signifying the new setting has been saved in memory The silent no volume tone is also selectable 9 9 9 9 7 4 N These volume control and beeper tone bar codes can also be found under the ...

Страница 32: ... non use Any movement detected by the IR will wake the scanner from the power save mode see Figure 28 This mode s wake time is slightly longer due to the motor s need to restart 4 Dual Action Power Save Mode 1 Blinks the laser OFF ON after a programmed period of non use turns the laser and motor OFF at thirty minute intervals Example If the power save timeout is set to 15 minutes Any movement dete...

Страница 33: ...29 Figure 28 IR Activation Area Parallel to Package Flow Specifications are subject to change without notice ...

Страница 34: ... Scan Volume Specifications BASED ON 100 UPC BAR CODES Figure 29 Scan Volume in Plane Perpendicular to Flow Figure 30 Scan Volume in Plane Parallel to Flow Specifications subject to change without notice ...

Страница 35: ...m Bar Code Element Width BASED ON 100 UPC BAR CODES Figure 31 Depth of Field Perpendicular to Flow Minimum Bar Code Element Width A B C D E mm 13 19 26 33 48 mils 5 2 7 5 10 4 13 19 Specifications subject to change without notice ...

Страница 36: ... the scanner 3 beeps on power up Non volatile RAM failure Contact a customer service representative if the unit will not hold the programmed configuration Continuous razz tone on power up RAM or ROM failure Contact a customer service representative if the unit will not function Razz tone and amber LED flash at power up VLD failure Contact a customer service representative Razz tone and both LEDs f...

Страница 37: ... stays on The scanner is configured to support some form of host handshaking but is not receiving the signal If the scanner is setup to support ACK NAK RTS CTS XON XOFF or D E verify that the host cable and host are supporting the handshaking properly The unit scans but the data transmitted to the host is incorrect The scanner s data format does not match the host system requirements Verify that t...

Страница 38: ...here is no data Configuration is not correct Make sure the scanner is configured for the appropriate mode The unit scans but the data is not correct Configuration is not correct Make sure that the proper PC type AT PS2 or XT is selected Verify correct country code and data formatting are selected Adjust intercharacter delay SYMPTOM The unit is transmitting each character Configuration is not corre...

Страница 39: ...er the PC is operating in Caps Lock Everything works except for a couple of characters These characters may not be supported by that country s key look up table Try operating the scanner in Alt mode Power up OK and scans OK but does not communicate properly to the host Com port at the host is not working or configured properly Check to make sure that the baud rate and parity of the scanner and the...

Страница 40: ... the 7600 com port marked Aux port The Aux com port may not be operating properly The 7600 must be programmed to enable the Aux port The auxiliary input port s data format must match the main output format of the secondary scanner Use MetroSet For the Auxiliary interface choose HoloTrak Decode All remaining parameters will be automatically chosen USB Only The scanner Powers up ok scans ok but does...

Страница 41: ...d bar codes for other symbologies call Honeywell System Interfaces PC Keyboard Wedge RS 232 OCIA Light Pen Stand Alone PC Keyboard USB RS485 Print Contrast 35 minimum reflectance difference No Characters Read up to 80 data characters Maximum number will vary based on symbology and density Roll Pitch Yaw 360 60 60 Beeper Operation 7 tones or no beep Indicators LED amber laser on ready to scan red g...

Страница 42: ...ser Class IEC 60825 1 2007 Class 1 EMC FCC ICES 003 EN 55022 Class B Environmental Operating Temperature 0 C to 40 C 32 F to 104 F Storage Temperature 40 C to 60 C 40 F to 140 F Humidity 5 to 95 relative humidity non condensing Light Levels 4842 LUX 450 foot candles Contaminants Sealed to resist airborne particulate contaminants Ventilation None required Specifications subject to change without no...

Страница 43: ... available in other Honeywell scanners are also available as keyboard wedge functions The following are the most important selectable options specific to the keyboard wedge Keyboard Type AT includes IBM PS2 models 50 55 60 80 XT IBM PS2 includes models 30 70 8556 Keyboard Country Type USA Italian Swiss Belgian Japanese Swedish Finnish French Russian Cyrillic Turkish German Slovenian United Kingdom...

Страница 44: ...meter If the communication supports a parameter listed in the charts on the following pages a check mark will appear PARAMETER DEFAULT OCIA RS 232 LIGHT PEN RS485 KBW USB UPC EAN Code 128 Code 93 Codabar Interleaved 2 of 5 ITF MOD 10 Check on ITF Code 11 Code 39 Full ASCII Code 39 MOD 43 Check on Code 39 MSI Plessey Airline 15 digit 2 of 5 Airline 13 digit 2 of 5 Matrix 2 of 5 Telepen UK Plessey S...

Страница 45: ...Three Beeps on Timeout No Beeps on Timeout Enter Power Save Mode 10 mins Blink Power Save Mode Laser OFF Power Save Mode Laser Motor OFF Power Save Mode Dual Action Power Save Mode 1 Dual Action Power Save Mode 2 Same Symbol Rescan Timeout 200 msecs Same Symbol Rescan Timeout 500 msecs Programmable in 50 msec steps MAX 6 35 seconds Same Symbol Rescan Timeout 1250 msecs Same Symbol Rescan Timeout 2...

Страница 46: ...t Transmit Lead Zero on UPC E Convert EAN 8 to EAN 13 Transmit UPC A Number System Transmit UPC A Manufacturer ID Transmit UPC A Item ID Transmit Codabar Start Stop Characters CLSI Editing Enable Transmit Mod 43 Check Digit on Code 39 Transmit Code 39 Stop Start Characters Transmit Mod 10 ITF Transmit MSI Plessey Check Characters Parity Space Baud Rate 9600 8 Data Bits 7 Data Bits Transmit Sanyo I...

Страница 47: ... FL Laser Enable Command DTR Handshaking Support RTS CTS Handshaking Character RTS CTS Message RTS CTS XON XOFF Handshaking ACK NAK Two Digit Supplements as code 39 Five Digit Supplements as code 39 Bookland 978 as code 39 Bookland 977 2 digit Supplemental Requirement Supplements are not Required Two Digit Redundancy Five Digit Redundancy 100 msec to Find Supplement Programmable in 100 msec steps ...

Страница 48: ... 10 avail Suffix Characters Prefixes for individual Code Types Editing Inter Scan Code Delay Programmable 100 µsec steps 800 µsec Function Control Key Support Minimum Element Width Programmable in 5 6 µsec steps 1 msec Depth of Field Variable Depth of Field Normal Depth of Field Extended Depth of Field Long Depth of Field Ultra Close Depth of Field ...

Страница 49: ... via various primary interfaces PARAMETER DEFAULT OCIA RS 232 LIGHT PEN RS485 KBW USB Aux Baud Rate 38400 Aux parity space Aux data bits 7 Aux stop bits 2 Aux character RTS Aux message RTS Aux Ack Nak Aux Xon Xoff Aux D E commands Aux M O commands Aux F L commands Aux Intercharacter Delay 1 msec Aux Port Data Format None Disabled ...

Страница 50: ... 13 OCIA MS762x 13 RS485 Pin Function Pin Function 1 Ground 1 Ground 2 NC 2 RS 232 Transmit Output 3 NC 3 RS 232 Receive Input 4 RDATA 4 RTS Output 5 RDATA Return 5 CTS Input 6 Clock in 6 DTR 7 Clock out 7 IBM B D 8 Clock in Return Clock out Rtrn 8 IBM A D 9 5VDC 9 5V IN 10 Shield Ground 10 NC MS762x 13 37 Auxilary Port RS232 IN Only Pin Function 1 Ground 2 RS 232 Receive Input 3 RS 232 Transmit O...

Страница 51: ...S 232 or Light Pen Pin Function Pin Function 1 Ground 1 Ground 2 USB D 2 RS 232 Transmit Output 3 USB D 3 RS 232 Receive Input 4 PC Data 4 RTS Output 5 PC Clock 5 CTS Input 6 KB Clock 6 DTR Input LTPN Source 7 PC 5V V USB 7 N C 8 KB Data 8 LTPN Data 9 5VDC 9 5VDC 10 Shield Ground 10 Shield Ground ...

Страница 52: ...owerLink Cable PN 54 54165 Type A Pin Function 1 N C 2 D 3 D 4 Ground PowerLink RS232 LSO AUX Cable PN 54 54667 Pin Function 1 Ground 2 RS 232 Transmit Output 3 RS 232 Receive Input 4 RTS Output 5 CTS Input 6 10 N C Stand Alone Keyboard Cable PN 54 54020 Pin Function 1 PC Data 2 NC 3 Power Ground 4 5VDC PC Power to KB 5 PC Clock 6 NC 9 Pin D Type Conn 9 5 6 1 1 10 10 pin Modular Plug USB Type A To...

Страница 53: ...and the keyboard port on the PC The pin assignments are as follows PowerLink Cable Adapter Cable 5 pin Female DIN 5 pin Male DIN Pin Function Pin Function 1 Keyboard Clock 1 PC Clock 2 Keyboard Data 2 PC Data 3 No Connect 3 No Connect 4 Power Ground 4 Power Ground 5 5 Volts DC 5 5 Volts DC 6 pin Male Mini DIN 6 pin Female Mini DIN Pin Function Pin Function 1 Keyboard Data 1 Keyboard Data 2 No Conn...

Страница 54: ...ng HII In the event that the product is returned to HII or its authorized service center within the Warranty Period and HII determines to its satisfaction that the product is defective due to defects in materials or workmanship HII at its sole option will either repair or replace the product without charge except for return shipping to HII EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW THE ...

Страница 55: ...f any peripherals not provided by the manufacturer may result in damage not covered by this warranty This includes but is not limited to cables power supplies cradles and docking stations HII extends these warranties only to the first end users of the products These warranties are non transferable The duration of the limited warranty for the 7600 is three 3 year s The accessories have a 90 day lim...

Страница 56: ...he equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Notice This Class B digital apparatus complies with Canadian ICES 003 Avertissement Cet appareil numérique de la class B est conforme à la norme NMB 003 Caution Use of controls or adjustments or performance of procedures other than those ...

Страница 57: ...hen den Laser Scanner selbst zu warten Sehen Sie niemals in den Laserstrahl selbst wenn Sie glauben daß der Scanner nicht aktiv ist Öffnen Sie niemals den Scanner um in das Gerät hineinzusehen Wenn Sie dies tun können Sie sich einer gefährlichen Laserstrahlung aussetzen Der Einsatz optischer Geräte mit dieser Laserausrüstung erhöht das Risiko einer Sehschädigung Attenzione L utilizzo di sistemi di...

Страница 58: ...tection 28 K Keyboard Type 39 Keyboard Wedge 1 2 12 37 39 47 L Labels 6 LED 4 24 25 32 33 37 Light Levels 38 Light Pen 1 16 17 18 37 39 40 41 42 43 44 45 47 Light Source 37 M Maintenance 5 Mechanical 37 Min Bar Width 37 Modes 28 N Normal Depth of Field 44 Notices 52 O OCIA 19 37 40 41 42 43 44 45 46 Operating Current 38 Operation 37 Operational 37 Output Window 4 P Parts 4 Port 45 46 Power Save 28...

Страница 59: ...co Telephone 01 800 HONEYWELL 01 800 466 3993 E mail soporte hsm honeywell com Europe Middle East and Africa Telephone 31 0 40 7999 393 Fax 31 0 40 2425 672 E mail hsmeurosupport honeywell com Hong Kong Telephone 852 29536436 Fax 852 2511 3557 E mail aptechsupport honeywell com Singapore Telephone 65 6842 7155 Fax 65 6842 7166 E mail aptechsupport honeywell com China Telephone 86 800 828 2803 Fax ...

Страница 60: ... 55 11 5185 8225 E mail brservice honeywell com Mexico Telephone 01 800 HONEYWELL 01 800 466 3993 Fax 52 55 5531 3672 E mail mxservice honeywell com Europe Middle East and Africa Telephone 31 0 40 2901 633 Fax 31 0 40 2901 631 E mail euroservice honeywell com Hong Kong Telephone 852 29536436 Fax 852 2511 3557 E mail apservice honeywell com Singapore Telephone 65 6842 7155 Fax 65 6842 7166 E mail a...

Страница 61: ......

Страница 62: ......

Страница 63: ......

Страница 64: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com 00 02870 Rev F 9 11 ...

Отзывы: