9.2  Red/green pilot LeD for 24 V DC/AC or for 

110 V AC to 230 V AC 

24 V DC, I = 16 mA; 24 V AC, I = 8 mA, Order No.: 

74921089.  
110 V AC to 230 V AC, Order No.: 74923275. 

 1 

 

 2 

 

 3 

 

 4 

NC

1

COM

3

NO

2

N

NO

2

1 NC

3 COM

+

9.3 Further accessories

Further information about accessories can be found in 

Technical Information bulletin DG (identical to DG..T) 

– www.docuthek.com.

10 teCHnICAL DAtA

10.1 safety information

Safety information, see Safety manual DG (identical 
to DG..T) – www.docuthek.com.

10.2 Ambient conditions

Maximum medium and ambient temperatures: 
DG:-40 to +140°F (-40 to +60°C). 
DG..S: 5 to +140°F (-15 to +60°C).
Long-term use in the upper ambient temperature 
range accelerates the ageing of the elastomer ma-
terials and reduces the service life (please contact 
manufacturer).

The set switching point may palpably change in media 

and ambient temperatures below -22°F (-30°C).

Transport temperature = ambient temperature.

Storage temperature: -4 to +104°F (-20 to +40°C).
Enclosure: IP 65.

This unit is not suitable for cleaning with a high-pres-

sure cleaner and/or cleaning products.

10.3 Mechanical data

Gas types: natural gas, town gas, LPG (gaseous), 
flue gas, biogas (max. 0.1 %-by-vol. H

2

S) and air..

Max. inlet pressure p

max.

 = withstand pressure: 

8.5 psi (600 mbar). 
Max. test pressure for testing the entire system: 
temporarily (< 15 minutes) 29 psi (2 bar).
Diaphragm pressure switch, silicone-free.
Diaphragm: DG: NBR, DG..S: IIR.
Housing: glass fibre reinforced PBT plastic with low 
gas release.
Lower housing section: AlSi 12.
Weight: 9.5 to 11.3 oz (270 to 320 g).
Recommended tightening torque:

Component

tightening 

torque 

[ncm]

Cover screws

65

½" NPT conduit

170 (15 lb")

Rp 1/8 pipe connection on 

aluminium lower section

250

Rp 1/4 connection (1/4” NPT) on 

aluminium lower section

1300

Rp 1/8 connection on upper 

housing section

250

Clamping terminal screws

80

2.76"

(70)

½" NPT Conduit

0.43"

(11)

Содержание DG-T Series

Страница 1: ...n accordance with the regulations and standards in force These instructions can also be found at www docuthek com 1 2 Explanation of symbols 1 2 3 a b c Action Instruction 1 3 Liability We will not be held liable for damage resulting from non observance of the instructions and non com pliant use 1 4 Safety instructions Information that is relevant for safety is indicated in the instructions as fol...

Страница 2: ...h cover 2 Lower housing section 3 Hand wheel 4 1 2 conduit coupling 5 Manual reset DG NT and DG HT only 2 3 Type label DG T Approval and type see type label For detailed information on the adjusting range mean switching differential max inlet pressure lock off me dium and switching properties see page 5 10 Technical data und and the table on page 3 5 Adjustment 3 INSTALLATION CAUTION Please observ...

Страница 3: ...articles in the surrounding air or in the medium Filter pad for port 4 The web app PartDetective for selecting spare parts is available at www ad latus org 4 WIRING CAUTION To ensure that the DL is not damaged during operation note the switching capacity see page 5 10 Technical data In the case of low switching capacities such as 24 V 8 mA for example we recommend using an RC mod ule 22 Ω 1 μF in ...

Страница 4: ...n 4 Difference between switching pressure and possible reset 6 PRESSURE SWITCHES WITH MAN UAL RESET DG NT locks off if the pressure drops to the value set using the hand wheel DG HT locks off if the pressure rises to the value set using the hand wheel 1 Reset the pressure switch using the manual reset Requirement for reset DG NT the pressure must have risen at least to the set switching point plus...

Страница 5: ...The set switching point may palpably change in media and ambient temperatures below 22 F 30 C Transport temperature ambient temperature Storage temperature 4 to 104 F 20 to 40 C Enclosure IP 65 This unit is not suitable for cleaning with a high pres sure cleaner and or cleaning products 10 3 Mechanical data Gas types natural gas town gas LPG gaseous flue gas biogas max 0 1 by vol H2S and air Max i...

Страница 6: ...the ambient conditions described Storage time 6 months in the original packaging before using for the first time If stored for longer than this the overall service life will be reduced by the corresponding amount of extra storage time 13 DISPOSAL Devices with electronic components WEEE Directive 2012 19 EU Waste Electrical and Electronic Equipment Directive At the end of the product life number of...

Отзывы: