background image

DeltaNet R7515A/B,

RP7515A/B, R7516B

MicroCel

 Controllers 

INSTALLATION INSTRUCTIONS 

Warning: This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance 
with the Instructions Manual, may cause interference with radio communication. It has been tested and found to comply with 
the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules, which are designed to provide 
reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in 
a residential area is likely to cause interference,  in which case, user at their own expense will be required to take whatever 
measures may be required to correct the interference. Any unauthorized modification of this equipment may result in the 
revocation of the owner's authority to continue its operation. 

BEFORE INSTALLATION 

�  

The DeltaNet MicroCel Controller (“MicroCel”), shown 
in Figure 1, is available in five models: 

—   R7515A MicroCel 

—  RP7515B MicroCel with Microbridge Airflow 

—   R7515B MicroCel with Microbridge Airflow Sensor 

Sensor and Electric-Pneumatic Transducer 

—   RP7515A MicroCel with Electric-Pneumatic 

—  R7516B MicroCel with Microbridge Airflow 

Transducer 

Sensor and Integral Damper Actuator 

AUXILIARY C-NAP 
SCREW TERMINALS J7 

INPUT SIDE 
BASEBOARD 

TERMINALS 

TERMINAL LABEL 

INPUTS

OUTPUTS 

24V AC AUXILIARY 
SCREW TERMINALS J12 

INPUT BOARD 

INPUTS

OUTPUTS 

WALL MOD 
CONNECTOR J8 

GROUND 
SCREW 

OUTPUT SIDE 
BASEBOARD 

24V AC/C-NAP MODULAR 
CONNECTOR J9 

24V AC 
AUXILIARY SCREW 
TERMINALS J11 

10 PIN CONNECTOR FOR 
ADDITIONAL MODULE, J14 

BRACKET 
MOUNTING 

TRIAC OUTPUT 
SCREW 
TERMINALS J6 

CASE 

OUTPUT 

BOARD 

A. INPUT BOARD SIDE 

B. OUTPUT  BOARD SIDE 

SCREW (2) 

THESE SCREWS MUST BE TIGHTLY INSERTED TO PROVIDE A GOOD GROUND FOR THE BOARDS. 

USE THIS SCREW TO GROUND THE MicroCel. 

C4359-3 

Fig. 1. MicroCel Internal View. 

Copyright © 1993 Honeywell Inc.  •  All Rights Reserved 

95-6083 

Содержание DeltaNet R7515A

Страница 1: ...peration BEFORE INSTALLATION The DeltaNet MicroCel Controller MicroCel shown in Figure 1 is available in five models R7515A MicroCel RP7515B MicroCel with Microbridge Airflow R7515B MicroCel with Microbridge Airflow Sensor Sensor and Electric Pneumatic Transducer RP7515A MicroCel with Electric Pneumatic R7516B MicroCel with Microbridge Airflow Transducer Sensor and Integral Damper Actuator AUXILIA...

Страница 2: ...icroCel in a vertical position so that the transducers will be oriented toward the bottom of the case and below the MicroCel PC boards This position prevents damage from condensation possible from main air CW C C W CW CCW 45 60 60 45 HIGH LOW 15 32 12 3 9 32 83 3 31 32 101 2 5 32 55 31 32 24 5 21 32 144 BARBED CONNECTOR 2 FOR DAMPER DAMPER ACTUATOR 1 4 IN 6 MM O D TUBING 3 4 5 1 4 133 11 16 19 6 1...

Страница 3: ...16 6 15 16 176 15 16 24 5 8 16 3 11 16 94 8 204 10 1 2 267 2 1 3 4 ACTUATOR SHAFT POSITION R7516B ONLY W 6 5 8 168 D FITTINGS USABLE QUANTITY DEPENDS KNOCKOUT 9 FOR 1 2 INCH CONDUIT 4 15 16 125 ON MODEL 4 13 16 DOUBLE KNOCKOUT 2 FOR 1 2 OR 122 3 4 INCH CONDUIT FITTINGS HOLE 2 FOR BARB CONNECTORS RP7515A B ACTUATOR R7516B ONLY C5653 Fig 3 Standard Case One Output Board MicroCel Approximate Dimensio...

Страница 4: ...per Actuator Remove the MicroCel cover by loosening the two cover mounting screws Fig 1 Mount the MicroCel in a location convenient to the equipment being controlled Use No 10 thread forming not thread cutting e g TEK screws obtained locally to secure the MicroCel to the mounting surface through the four key holes inside the case Replace and secure the MicroCel cover after wiring and piping Model ...

Страница 5: ... following a Direction the damper shaft moves to open the damper Fig 6 cw or ccw b Size of damper shaft 3 8 or 1 2 in 9 or 12 mm NOTE Damper shaft must extend at least 2 1 2 in 63 mm from damper housing c Degrees of travel for damper to open Fig 6 45 60 or 90 degrees AIRFLOW AIRFLOW CW TO OPEN CCW TO CLOSE 45 DEGREE ROTATION 60 DEGREE ROTATION 90 DEGREE ROTATION CCW TO OPEN CW TO CLOSE C3957 1 Fig...

Страница 6: ...nge Stop Pin PIPING Airflow Pickup Where Used Connect the airflow pickup to the two 1 4 in 6 mm barb connectors on the MicroCel case location shown in Fig 2 3 or 4 Connect the high pressure or upstream tube to the plastic restrictor barb labeled HIGH and the low pressure or downstream tube to the plastic restrictor barb labeled LOW When twin tubing is used from the pickup split the tubing a short ...

Страница 7: ...rt too much pressure on wiring and can cause a short Power and Communications Bus The MicroCel C NAP communications bus and 24V ac power wiring is normally done with the AK3711 DeltaNet MicroCel Bus Cable Assembly See the Connections Using AK3711 Bus and AK3326 T Tap Cable Assembly section For alternate methods for connecting the C NAP communications bus and 24V ac power wiring see the Connections...

Страница 8: ...ectrical connections press down each of four connector buttons with channel lock pliers d Connector buttons should be flush with cover when properly secured BUTTONS RS 485 4 C NAP 24V AC FROM CLASS II POWER SOURCE COVER BASE C3506 4 Fig 11 Installing Bus Conductors in T Tap Connector BLUE RED YELLOW BLACK YELLOW BLACK BLUE RED TO CONTROLLER Connect plug on AK3326 T Tap Cable Assembly into Connecto...

Страница 9: ...2 Fig 14 Installing AK3702R or AK3744 Bus Cable Using Screw Terminals 15 through 18 in MicroCel Bus Termination Resistor Insert a Bus Termination Resistor 14501600 028 on all C NAP bus configurations per job drawings If the MicroCel is at the end of a main or secondary trunk mount the resistor on the terminal strip as shown in Figure 15 14501600 028 RESISTOR T1 T2 RED YELLOW BLACK BLUE RED YEL AK3...

Страница 10: ... 7 8 9 10 11 12 13 14 4 R1 D1 10 V1 R2 D2 10 V2 VOLT DIG RTD VOLT DIG RTD OUTPUTS INPUTS RET 1 2 3 21 22 23 25 26 27 28 29 30 31 32 33 34 24 T2 35 A B ANALOG RELAY T1 24V AC J11 C NAP J7 J8 J9 AO 1 AO 2 AO 3 K1 K2 K3 36 37 38 40 41 39 43 42 T1 T2 1 1 2 2 3 COM 3 4 4 TRIAC 24V AC COM 15 17 18 16 WALL MOD 24V AC C NAP BUS PNEU B PNEU A A C B A C B A C B A ALL CONTROLLER MODELS 19 20 1 2 3 5 6 7 8 9 ...

Страница 11: ...5 R4222 PT3000 TEMP SENSOR T7005 6 7 8 CLASS II EXTERNAL TRANSFORMER WITH 24V AC SECONDARY DO NOT GROUND EITHER LEG TO POWER AND C NAP COMMUNICATIONS BUS LINE VOLTAGE FAN SPEED CONTROL 2 10V DC UNIT VENT MODULATING VALVE 2 10V DC C3205 2 OUTDOOR AIR DAMPER ACTUATOR 2 TO 10V DC N C ON POWER FAILURE 1K 3K FACTORY PREWIRED IF INTEGRAL TO CONTROLLER C1 LINE VOLTAGE ML6161B SERIES 60 FLOATING DAMPER AC...

Страница 12: ...Control Home and Building Control Honeywell Inc Honeywell Limited Honeywell Limitée Honeywell Plaza 155 Gordon Baker Road P O Box 524 North York Ontario Minneapolis MN 55408 0524 M2H 3N7 95 6083 Rev 2 93 Printed in U S A ...

Отзывы: