CN80 Mobile Computer Series User Guide
25
In Automatic mode with
Preemptive Heating
enabled, the cold storage battery
life ranges from a maximum of 6 hours to a minimum of 1.5 hours, depending
on the heater
Preemptive delay time
set. The window defrost times range from
zero to a maximum of one minute with factory default settings.
•
Manual mode
This mode is disabled by default. When enabled, heater activation is controlled
solely by the user. No temperature monitoring and timers are used to control
the heaters. The user must manually turn the heaters On or Off.
Use the
Settings
app to configure the
Heater
feature. To learn how, see
How Automatic Mode Works
Automatic heater management saves power since the heaters are automatically
controlled by the system based on cold storage entry/exit detection.
Cold Storage Entry Detection
In
Automatic
mode, cold storage entry detection occurs when the computer
sensors identify a drop in ambient temperature below the defined
Heater enable
temperature
. The system starts the
Chill timer
in response to cold storage entry
detection.
Note:
If you remove the computer from cold storage before the Chill timer expires, the timer
stops and the system does not turn On the heaters, saving battery power.
A snowflake
icon appears in the status bar when the Chill timer expires.
Cold Storage Exit Detection
In
Automatic
mode, cold storage exit detection occurs when the sensors identify a
quick rise in the ambient temperature.
•
If
Preemptive Heating
is disabled (default) and the
Chill time
has expired, the
system turns the heaters On at full power when a cold storage exit is detected.
•
If
Preemptive Heating
is enabled and the
Chill time
has expired, the system
starts the
Preemptive
delay
time
. When the
Preemptive delay
time
expires, the
heaters enter a low-power pre-heat stage. Pre-heating keeps the windows warm
to minimize condensation and frost when the computer is removed from cold
storage, allowing for quicker defrost times. The system turns the heaters On full
power when a cold storage exit is detected.
Note:
When the heaters turn On, the icon changes from a snowflake
to a heater
.
Содержание CN80 Series
Страница 1: ...User Guide CN80 Series Mobile Computer powered by Android ...
Страница 4: ...iv CN80 Mobile Computer Series User Guide ...
Страница 39: ...CN80 Mobile Computer Series User Guide 29 6 Lift up on the edge of the battery and remove it from the computer ...
Страница 44: ...34 CN80 Mobile Computer Series User Guide ...
Страница 66: ...56 CN80 Mobile Computer Series User Guide ...
Страница 70: ...60 CN80 Mobile Computer Series User Guide 7 Lift up on the edge of the battery and remove it from the computer ...
Страница 122: ...112 CN80 Mobile Computer Series User Guide ...
Страница 123: ......
Страница 124: ... Honeywell 855 S Mint Street Charlotte NC 28202 sps honeywell com CN80 A EN UG 01 Rev G 10 22 ...