Code 93 On/Off

Code 93 Message Length

Scan the bar codes below to change the message length. Refer to 

Message Length 

Description

 (page 76) for additional information. Minimum and Maximum lengths 

= 0-80. Minimum Default = 0, Maximum Default = 80.

Code 93 Append

This function allows the scanner to append the data from several Code 93 bar 
codes together before transmitting them to the host computer. When this function 
is enabled, the scanner stores those Code 93 bar codes that start with a space 
(excluding the start and stop symbols), and does not immediately transmit the 
data. The scanner stores the data in the order in which the bar codes are read, 
deleting the first space from each. The scanner transmits the appended data when 
it reads a Code 93 bar code that starts with a character other than a space. 

Default 

= Off.

* On

Off

Minimum Message Length

Maximum Message Length

On

* Off

Содержание CF3680

Страница 1: ...User Guide N3680 CF3680 Decoded Engine and 2D Imager Module ...

Страница 2: ...information that is protected by copyright All rights are reserved No part of this docu ment may be photocopied reproduced or translated into another language without the prior written consent of HII Copyright 2015 2017 Honeywell International Inc All rights reserved Other product names or marks mentioned in this document may be trademarks or registered trademarks of other compa nies and are the p...

Страница 3: ...Your Device 1 OEM Scan Engine Models 2 Connect the Development N3680 Scan Engine to a PC 2 Connect with USB 2 Connect with RS232 Serial Port 3 Connect the CF3680 to a Host 4 Reading Techniques 4 Menu Bar Code Security Settings 5 Set Custom Defaults 5 Reset the Custom Defaults 6 Chapter 2 Program the Interface 7 Introduction 7 Program the Interface Plug and Play 7 RS232 Serial Port 7 USB PC or Maci...

Страница 4: ...dorf RS232 Mode A 11 Keyboard Country Layout 12 Keyboard Countries 12 Keyboard Style 19 Keyboard Conversion 20 Control Character Output 21 Keyboard Modifiers 21 RS232 Modifiers 23 RS232 Baud Rate 23 RS232 Word Length Data Bits Stop Bits and Parity 24 RS232 Receiver Time Out 25 RS232 Handshaking 25 RS232 Timeout 26 XON XOFF 26 ACK NAK 27 RS232 Stop Mode 27 Scanner to Bioptic Communication 27 Scanne...

Страница 5: ... Trigger Mode 34 LED Illumination Manual Trigger 34 Character Activation Mode 34 Activation Character 35 End Character Activation After Good Read 35 Character Activation Timeout 35 Character Deactivation Mode 36 Deactivation Character 36 Serial Trigger Mode 36 Read Time Out 36 Presentation Mode 37 Idle Illumination Presentation Mode 37 Presentation Sensitivity 38 Presentation Centering 38 CodeGate...

Страница 6: ...tial Sequence 50 Require Output Sequence 51 Multiple Symbols 51 No Read 52 Video Reverse 53 Working Orientation 54 Chapter 4 Data Editing 55 Prefix Suffix Overview 55 Points to Keep In Mind 55 To Add a Prefix or Suffix 56 Example Add a Tab Suffix to All Symbologies 56 To Clear One or All Prefixes or Suffixes 57 To Add a Carriage Return Suffix to All Symbologies 57 Prefix Selections 57 Suffix Selec...

Страница 7: ...arch Commands 68 Miscellaneous Commands 70 Data Formatter 73 Primary Alternate Data Formats 74 Chapter 6 Symbologies 75 All Symbologies 76 Message Length Description 76 Codabar 76 Codabar On Off 77 Codabar Start Stop Characters 77 Codabar Check Character 77 Codabar Concatenation 78 Codabar Message Length 78 Code 39 79 Code 39 On Off 79 Code 39 Start Stop Characters 79 Code 39 Check Character 79 Co...

Страница 8: ...ge 86 Straight 2 of 5 Industrial three bar start stop 86 Straight 2 of 5 Industrial On Off 86 Straight 2 of 5 Industrial Message Length 86 Straight 2 of 5 IATA two bar start stop 87 Straight 2 of 5 IATA On Off 87 Straight 2 of 5 IATA Message Length 87 Matrix 2 of 5 87 Matrix 2 of 5 On Off 87 Matrix 2 of 5 Message Length 88 Code 11 88 Code 11 On Off 88 Check Digits Required 89 Code 11 Message Lengt...

Страница 9: ...r Output 95 UPC E0 95 UPC E0 On Off 95 UPC E0 Expand 95 UPC E0 Addenda Required 96 UPC E0 Addenda Separator 96 UPC E0 Check Digit 96 UPC E0 Leading Zero 97 UPC E0 Addenda 97 UPC E1 97 EAN JAN 13 98 EAN JAN 13 On Off 98 Convert UPC A to EAN 13 98 EAN JAN 13 Check Digit 99 EAN JAN 13 Addenda 99 EAN JAN 13 Addenda Required 99 EAN JAN 13 Addenda Separator 100 ISBN Translate 100 EAN JAN 8 100 EAN JAN 8...

Страница 10: ...f 105 GS1 DataBar Expanded Message Length 105 Codablock A 105 Codablock A On Off 105 Codablock A Message Length 106 Codablock F 106 Codablock F On Off 106 Codablock F Message Length 106 PDF417 107 PDF417 On Off 107 PDF417 Message Length 107 MacroPDF417 107 MicroPDF417 108 MicroPDF417 On Off 108 MicroPDF417 Message Length 108 GS1 Composite Codes 108 UPC EAN Version 109 GS1 Composite Code Message Le...

Страница 11: ...ztec Append 115 Aztec Code Page 116 Chinese Sensible Han Xin Code 116 Han Xin Code On Off 116 Han Xin Code Message Length 117 Postal Codes 2D 117 Single 2D Postal Codes 117 Combination 2D Postal Codes 118 Planet Code Check Digit 120 Postnet Check Digit 121 Australian Post Interpretation 121 Postal Codes Linear 122 China Post Hong Kong 2 of 5 122 Korea Post 123 Chapter 7 Imaging Commands 125 Single...

Страница 12: ...ZConfig Cloud for Scanning Tool 141 Resetting the Factory Defaults 142 Chapter 9 Serial Programming Commands 143 Conventions 143 Menu Command Syntax 144 Serial Command Example 144 Trigger Commands 147 Setting the Custom Defaults 147 Resetting the Custom Defaults 147 Menu Commands 148 Chapter 10 Maintenance and Troubleshooting 169 Repairs 169 Inspecting Cords and Connectors 169 Troubleshooting 169 ...

Страница 13: ...ser Guide xiii ASCII Conversion Chart Code Page 1252 174 Lower ASCII Reference Table 175 ISO 2022 ISO 646 Character Replacements 180 Keyboard Key References 182 Sample Symbols 183 Programming Chart 185 Programming Chart 187 ...

Страница 14: ...xiv N3680 Decoded Engine User Guide ...

Страница 15: ...warranty or non warranty service you must first obtain a Return Material Authorization number RMA then return the product to Honeywell postage paid with a copy of the dated purchase record To learn more go to www honeywellaidc com and select Service Repair at the bottom of the page Limited Warranty For warranty information go to www honeywellaidc com and click Get Resources Product Warranty Send F...

Страница 16: ...xvi N3680 Decoded Engine User Guide ...

Страница 17: ...e kiosk It is optimized to read 1D and 2D bar codes on mobile phone screens coupons loyalty cards or tickets at close reading distances About This Manual This User s Guide provides demonstration and programming instructions for the N3680 scan engine and CF3680 2D imager module Honeywell s bar code scan engines are factory programmed for the most common terminal and communications settings If you n...

Страница 18: ...cate USB through the 10 pin modular connector a Turn off power to the terminal computer b If using full speed USB connect the USB interface cable to the interface board and to the matching USB port on the computer c Verify the scan engine operation by scanning a bar code from the Sample Symbols in the back of this manual The scan engine beeps once when a bar code is successfully decoded Note The d...

Страница 19: ... the power supply connector to the serial interface cable Plug in the power supply c Turn the terminal computer power back on The scan engine beeps d If connecting the scan engine using an RS 232 interface all communication parameters between the scan engine and terminal must match for correct data transfer through the serial port using RS 232 protocol Scan the RS 232 interface bar code below This...

Страница 20: ...onnect a scan engine to your host system refer to the N36XX Integration Man ual Connect the CF3680 to a Host For information on connecting the CF3680 to a host see the CF3680 Installation Guide available from your local OEM representative Reading Techniques The scan engine has a view finder that projects a bright red aiming square The aiming beam should be centered over the bar code but it can als...

Страница 21: ...ttings Contact your Hon eywell OEM representative for more information Set Custom Defaults You have the ability to create a set of menu commands as your own custom defaults To do so scan the Set Custom Defaults bar code below before scanning the menu commands for your custom defaults If a menu command requires scan ning numeric codes from the back cover then a Save code that entire sequence will b...

Страница 22: ...efault bar code for most users It resets the scan engine to the custom default settings If there are no custom defaults it will reset the scan engine to the factory default settings Any settings that have not been specified through the custom defaults will be defaulted to the factory default settings Note To remove custom defaults see Resetting the Factory Defaults on page 8 142 Activate Custom De...

Страница 23: ... After you scan one of the codes power cycle the host terminal to have the interface in effect RS232 Serial Port The RS232 Interface bar code is used when connecting to the serial port of a PC or terminal It also programs a carriage return CR and a line feed LF suffix baud rate and data format as indicated below It also changes the trigger mode to man ual Option Setting Baud Rate 115 200 bps Data ...

Страница 24: ...s USB Serial Scan the following code to program the scan engine to emulate a regular RS232 based COM Port If you are using a Microsoft Windows PC you will need to down load a driver from the Honeywell website www honeywellaidc com The driver will use the next available COM Port number Apple Macintosh computers recognize the scan engine as a USB CDC class device and automatically use a class driver...

Страница 25: ...following prefixes for each symbology Gilbarco Terminal Default Settings Scan the following Plug and Play code to program the scan engine for a Gilbarco terminal This bar code sets the baud rate to 2400 bps and the data format to 7 data bits even parity 2 stop bits It also adds a carriage return CR suffix and pro grams the following prefixes for each symbology ACK NAK Mode On ACK NAK Mode Off Symb...

Страница 26: ...an auxiliary port configuration This bar code sets the baud rate to 9600 bps and the data format to 8 data bits no parity 1 stop bit NCR Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scan engine for an NCR bioptic scanner auxiliary port configuration The following prefixes are pro grammed for each symbology Honeywell Bioptic Settings Datalogic Magellan Bioptic...

Страница 27: ... program the scanner for a Wincor Nixdorf RS232 Mode A terminal This bar code sets the baud rate to 9600 bps and the data format to 8 data bits odd parity 1 stop bit The following prefixes are programmed for each symbology Wincor Nixdorf Terminal Settings Symbology Prefix Symbology Prefix Aztec Code V Interleaved 2 of 5 I Codabar N MaxiCode T Code 93 L MicroPDF417 S Code 128 K PDF417 Q Data Matrix...

Страница 28: ...gram the keyboard layout for your country or language As a general rule the following characters are supported but need special care for countries other than the United States WincorNixdorfRS232 ModeA Settings Keyboard Countries United States Albania Azeri Cyrillic Azeri Latin Belarus Belgium Bosnia Brazil ...

Страница 29: ... Engine User Guide 13 Keyboard Countries Continued Brazil MS Bulgaria Cyrillic Bulgaria Latin Canada French legacy Canada French Canada Multilingual Croatia Czech Czech Programmers Czech QWERTY Czech QWERTZ Denmark ...

Страница 30: ...14 N3680 Decoded Engine User Guide Keyboard Countries Continued Dutch Netherlands Estonia Faroese Finland France Gaelic Germany Greek Greek 220 Latin Greek 220 Greek 319 Latin Greek 319 ...

Страница 31: ...N3680 Decoded Engine User Guide 15 Keyboard Countries Continued Greek Latin Greek MS Greek Polytonic Hebrew Hungarian 101 key Hungary Iceland Irish Italian 142 Italy Japan ASCII Kazakh ...

Страница 32: ...16 N3680 Decoded Engine User Guide Keyboard Countries Continued Kyrgyz Cyrillic Latin America Latvia Latvia QWERTY Lithuania Lithuania IBM Macedonia Malta Mongolian Cyrillic Norway Poland Polish 214 ...

Страница 33: ...0 Decoded Engine User Guide 17 Keyboard Countries Continued Polish Programmers Portugal Romania Russia Russian MS Russian Typewriter SCS Serbia Cyrillic Serbia Latin Slovakia Slovakia QWERTY Slovakia QWERTZ ...

Страница 34: ...680 Decoded Engine User Guide Keyboard Countries Continued Slovenia Spain Spanish variation Sweden Switzerland French Switzerland German Tatar Turkey F Turkey Q Ukrainian United Kingdom United States Dvorak ...

Страница 35: ...eyboard Style settings Default Regular Regular is used when you normally have the Caps Lock key off Caps Lock is used when you normally have the Caps Lock key on Shift Lock is used when you normally have the Shift Lock key on not common to U S keyboards Keyboard Countries Continued United States Dvorak left United Stated Dvorak United States International Uzbek Cyrillic Regular Caps Lock Shift Loc...

Страница 36: ...ld be scanned if you do not have an external key board IBM AT or equivalent Note After scanning the Emulate External Keyboard bar code you must power cycle your computer Keyboard Conversion Alphabetic keyboard characters can be forced to be all upper case or all lowercase So if you have the following bar code abc569GK you can make the output ABC569GK by scanning Convert All Characters to Upper Cas...

Страница 37: ... as CTRL ASCII codes and Turbo Mode Control X Control ASCII Mode On The scan engine sends key combinations for ASCII control characters for values 00 1F Windows is the preferred mode All keyboard country codes are supported DOS mode is a legacy mode and it does not support all keyboard country codes New users should use the Windows mode Refer to ASCII Conversion Chart Code Page 1252 page 174 for C...

Страница 38: ...umeric characters as if entered from a numeric keypad Default Off Automatic Direct Connect Mode This selection can be used if you have an IBM AT style terminal and the system is dropping characters Default Off Windows Mode Control X Mode On Control X Mode Off DOS Mode Control X Mode On Windows Mode Prefix Suffix Turbo Mode On Turbo Mode Off Numeric Keypad Mode On Numeric Keypad Mode Off Automatic ...

Страница 39: ...2 Baud Rate Baud Rate sends the data from the scan engine to the terminal at the specified rate The host terminal must be set for the same baud rate as the scan engine Default 115200 Automatic Direct Connect Mode Off 300 600 1200 2400 4800 9600 19200 38400 ...

Страница 40: ...tion select 7 data bits For applications that require use of the full ASCII set select 8 data bits per character Default 8 Stop Bits sets the stop bits at 1 or 2 Default 1 Parity provides a means of checking character bit patterns for validity Default None 57 600 115 200 7 Data 1 Stop Parity Even 7 Data 1 Stop Parity None 7 Data 1 Stop Parity Odd 7 Data 2 Stop Parity Even 7 Data 2 Stop Parity None...

Страница 41: ...side back cover of this manual then scanning Save The range is 0 to 300 seconds Default 0 seconds no time out always on RS232 Handshaking RS232 Handshaking allows control of data transmission from the scan engine using software commands from the host device When RTS CTS is turned Off no data flow control is used Flow Control No Timeout The scan engine asserts RTS when it has data to send and will ...

Страница 42: ...illiseconds for a time out by scanning the bar code below then setting the timeout from 1 5100 milli seconds by scanning digits from the inside back cover then scanning Save XON XOFF Standard ASCII control characters can be used to tell the scan engine to start sending data XON XOFF On or to stop sending data XON XOFF Off When the host sends the XOFF character DC3 hex 13 to the scan engine data tr...

Страница 43: ... code below To turn off the protocol scan ACK NAK Off Default ACK NAK Off RS232 Stop Mode Scan the following bar code to force the engine into a stop mode Restart the engine by using a trigger pull nWake or RxD toggle Scanner to Bioptic Communication The following settings are used to set up communication between Honeywell scan engines and bioptic scanners Note The scan engine s baud rate must be ...

Страница 44: ...er after each packet is sent The Scanner Bioptic ACK NAK Timeout below controls how long the scanner will wait for a response Default Bioptic ACK NAK Off Scanner Bioptic ACK NAK Timeout This allows you to set the length in milliseconds for a timeout for a bioptic scan ner s ACK NAK response Scan the bar code below then set the timeout from 1 30 000 milliseconds by scanning digits from the inside b...

Страница 45: ... a power up beep Default Power Up Beeper On Scanner Beep on BEL Character You may wish to force the scan engine to beep upon a command sent from the host If you scan the Beep on BEL On bar code below the scan engine will beep every time a BEL character is received from the host Default Beep on BEL Off Power Up Beeper Off Scanner Power Up Beeper On Scanner Beep on BEL Off Beep on BEL On ...

Страница 46: ...gger Click Off Good Read and Error Indicators Beeper Good Read The beeper may be programmed On or Off in response to a good read Turning this option off only turns off the beeper response to a good read indication All error and menu beeps are still audible Default Beeper Good Read On Beeper Volume Good Read The beeper volume codes modify the volume of the beep the scan engine emits on a good read ...

Страница 47: ...cy of the beep the scan engine emits on a good read Default Medium Beeper Pitch Error The beeper pitch codes modify the pitch frequency of the sound the scan engine emits when there is a bad read or error Default Razz High Off Low 1600 Hz Medium 2400 Hz High 4200 Hz Razz 250 Hz Medium 3250 Hz High 4200 Hz ...

Страница 48: ... five beeps there will be five beeps and five LED flashes in response to a good read The beeps and LED flashes are in sync with one another To change the number of beeps scan the bar code below and then scan a digit 1 9 bar code and the Save bar code on the Programming Chart inside the back cover of this manual Default 1 Number of Beeps Error The number of beeps and LED flashes emitted by the scan...

Страница 49: ...ts the minimum amount of time before the scan engine can read another bar code Default 0 ms No Delay User Specified Good Read Delay If you want to set your own length for the good read delay scan the bar code below then set the delay from 0 30 000 milliseconds by scanning digits from the inside back cover then scanning Save Number of Error Beeps LED Flashes No Delay Short Delay 500 ms Medium Delay...

Страница 50: ...light in the room the brighter the LEDs need to be so the scan engine can see the bar codes Character Activation Mode You may use a character sent from the host to trigger the scanner to begin scan ning When the activation character is received the scanner continues scanning until either the Character Activation Timeout page 3 35 the deactivation charac ter is received see Deactivation Character o...

Страница 51: ...n End Character Activation After Good Read is enabled the illumination turns off and stops scanning after a good read If you scan Do Not End Character Activa tion After Good Read the illumination remains on after a good read Default Do Not End Character Activation After Good Read Character Activation Timeout You can set a timeout for the length of time the illumination remains on and attempting to...

Страница 52: ...g Chart inside the back cover of this manual to read the alphanumeric combination that represents that ASCII character Scan Save to finish Default 14 DC4 Serial Trigger Mode You can activate the scan engine either by pressing the trigger or using a serial trigger command see Trigger Commands on page 147 When in serial mode the scan engine scans until a bar code has been read or until the deactivat...

Страница 53: ... the CF3680 Scan the following bar code to program your scanner for Presentation Mode Idle Illumination Presentation Mode Scan one of the bar codes below to set the LED illumination for the scanner when it is in an idle state in Presentation Mode Default On Note If you use one of the lower Idle Illumination settings and there is not enough ambient light the scanner may have difficulty detecting wh...

Страница 54: ...stand to make sure the scanner reads only those bar codes intended by the user For instance if multiple codes are placed closely together Presentation Centering will insure that only the desired codes are read Note To adjust centering when the scanner is hand held see Centering page 3 46 If a bar code is not touched by a predefined window it will not be decoded or output by the scanner If Presenta...

Страница 55: ...ar Code 1 passes through the centering window it will be read Bar Code 2 does not pass through the centering window so it will not be read Note A bar code needs only to be touched by the centering window in order to be read It does not need to pass completely through the centering window 0 Bar Code 1 Bar Code 2 10 20 30 40 50 60 70 80 90 100 100 90 80 70 60 50 40 30 20 10 0 ...

Страница 56: ...on page 7 125 you must set the In Stand Sensor to Off You may program a Streaming Presentation Mode Normal Enhanced or Mobile Phone you wish to use for in stand scanning and a Manual Trigger mode Nor mal Enhanced or Mobile Phone you wish to use for out of stand scanning To do this you must first scan the preferred Streaming Presentation mode see below then scan the Manual Trigger mode see page 34 ...

Страница 57: ... CodeGate Off Out of Stand Mobile Phone Read Mode When this mode is selected your scanner is optimized to read bar codes from mobile phone or other LED displays However the speed of scanning printed bar codes may be slightly lower when this mode is enabled Note Presentation scanning is not recommended to be used with the CF3680 Note To turn off Mobile Phone Read Mode scan a Manual or Serial Trigge...

Страница 58: ...en Poor Quality PDF On is scanned poor quality PDF code reading is improved but the scanner s snap piness is decreased making it less aggressive when reading good quality bar codes This setting does not affect 1D bar code reading Default Poor Quality PDF Reading Off Hands Free Time Out The Scan Stand and Presentation Modes are referred to as hands free modes If the scanner s trigger is pulled when...

Страница 59: ...me bar code Longer delays are effective in minimizing accidental rereads Use shorter delays in applications where repetitive bar code scanning is required Reread Delay only works when in a Presentation Mode see page 37 Default Medium User Specified Reread Delay If you want to set your own length for the reread delay scan the bar code below then set the delay from 0 30 000 milliseconds by scanning ...

Страница 60: ... Delay is used for both 1D and 2D bar codes Default 2D Reread Delay Off Illumination Lights If you want the illumination lights on while reading a bar code scan the Lights On bar code below However if you want to turn just the lights off scan the Lights Off bar code Default Lights On Note This setting does not affect the aimer light The aiming light can be set using Aimer Mode page 45 2D Reread De...

Страница 61: ... delay scan the bar code below then set the time out by scanning digits 0 4 000 ms from the Programming Chart inside the back cover of this manual then scan Save Aimer Mode This feature allows you to turn the aimer on and off When turning the aimer on there are 2 options Interlaced the aimer is interlaced with the illumination LEDs and Interlace Optimized for Decode same as Interlaced except the a...

Страница 62: ...e most error free operation in applications where multiple codes are spaced closely together Using the Aimer Delay and Centering features the scanner can emulate the operation of older systems such as linear laser bar code scanners If a bar code is not touched by a predefined window it will not be decoded or output by the scan engine If centering is turned on by scanning Centering On the scan engi...

Страница 63: ...ntering window in order to be read It does not need to pass completely through the centering window Scan Centering On then scan one of the following bar codes to change the top and bottom of the centering window Then scan the percent you want to shift the centering window using digits on the inside back cover of this manual Scan Save Default Centering 40 for Top 60 for Bottom 0 Bar Code 1 Bar Code...

Страница 64: ...gy Charts on page 171 find the symbology to which you want to apply the output sequence format Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart inside back cover c Length Specify what length up to 9999 characters of data output will be acceptable for this symbology Scan the four digit data length from the Programming Chart Note 50 characters is ente...

Страница 65: ...ic code lengths you would use the following command line SEQBLK62001241FF6A001342FF69001243FF A Code 39 B Code 128 C Code 93 SEQBLK sequence editor start command 62 code identifier for Code 39 9999 code length that must match for Code 39 9999 all lengths 41 start character match for Code 39 41h A FF termination string for first code 6A code identifier for Code 128 9999 code length that must match ...

Страница 66: ...mit partial sequences Any fields in the sequence where no data match occurred will be skipped in the output 41 start character match for Code 39 41h A FF termination string for first code 6A code identifier for Code 128 0013 B Code 128 sample length 12 plus CR suffix 1 13 42 start character match for Code 128 42h B FF termination string for second code 69 code identifier for Code 93 0012 C Code 93...

Страница 67: ...put to the host as the scan engine decodes it Default Off Note This selection is unavailable when the Multiple Symbols Selection is turned on Multiple Symbols When this programming selection is turned On it allows you to read multiple sym bols with a single pull of the scanner s trigger If you press and hold the trigger aiming the scanner at a series of symbols it reads unique symbols once beeping...

Страница 68: ...g Scanning Tool Scan Data Window see page 140 an NR appears when a code cannot be read If No Read is turned Off the NR will not appear Default Off If you want a different notation than NR for example Error or Bad Code you can edit the output message see Data Formatting beginning on page 5 61 The hex code for the No Read symbol is 9C On Off ...

Страница 69: ... read only inverted bar codes Scan Video Reverse and Standard Bar Codes to read both types of codes Note After scanning Video Reverse Only menu bar codes cannot be read You must scan Video Reverse Off or Video Reverse and Standard Bar Codes in order to read menu bar codes Note Images downloaded from the unit are not reversed This is a setting for decoding only Video Reverse Only Video Reverse and ...

Страница 70: ...n scanned sideways or upside down Use the working orientation settings if your direction sensitive codes will not usually be presented upright to the scanner Default Upright Upright Vertical Top to Bottom Rotate CW 90 Upside Down Vertical Bottom to Top Rotate CCW 90 Upright Vertical Bottom to Top Upside Down Vertical Top to Bottom ...

Страница 71: ...gies The following illustration shows the breakdown of a message string Points to Keep In Mind It is not necessary to build a message string The selections in this chapter are only used if you wish to alter the default settings Default prefix None Default suffix None A prefix or suffix may be added or cleared from one symbology or all symbologies You can add any prefix or suffix from the ASCII Con...

Страница 72: ...page 174 for the prefix or suffix you wish to enter Note To add the Code I D scan 5 C 8 0 To add AIM I D scan 5 C 8 1 To add a backslash scan 5 C 5 C To add a backslash as in Step 7 you must scan 5C twice once to create the leading backslash and then to create the backslash itself Step 5 Scan the 2 digit hex value from the Programming Chart inside the back cover of this manual Step 6 Repeat Steps ...

Страница 73: ...ne the 2 digit Hex value from the Symbology Chart included in the Symbology Charts beginning on page 171 for the symbology from which you want to clear the prefix or suffix Step 3 Scan the 2 digit hex value from the Programming Chart inside the back cover of this manual or scan 9 9 for all symbologies Your change is automatically saved To Add a Carriage Return Suffix to All Symbologies Scan the fo...

Страница 74: ... Conversion Chart Code Page 1252 starting on page 174 When the scanner is in keyboard wedge mode the scan code is converted to a key code before it is transmitted Default Enable Intercharacter Interfunction and Intermessage Delays Some terminals drop information characters if data comes through too quickly Intercharacter interfunction and intermessage delays slow the transmission of data increasin...

Страница 75: ...er Specified Intercharacter Delay An intercharacter delay of up to 5000 milliseconds in 5ms increments may be placed after the transmission of a particular character of scanned data Scan the Delay Length bar code below then scan the number of 5ms delays and the Save bar code using the Programming Chart inside the back cover of this manual Next scan the Character to Trigger Delay bar code then the ...

Страница 76: ...Programming Chart inside the back cover of this manual Intermessage Delay An intermessage delay of up to 5000 milliseconds in 5ms increments may be placed between each scan transmission Scan the Intermessage Delay bar code below then scan the number of 5ms delays and the Save bar code using the Programming Chart inside the back cover of this manual To remove this delay scan the Intermessage Delay ...

Страница 77: ...hey are stacked in the order in which they are entered However the following list presents the order in which formats are applied 1 Specific Terminal ID Actual Code ID Actual Length 2 Specific Terminal ID Actual Code ID Universal Length 3 Specific Terminal ID Universal Code ID Actual Length 4 Specific Terminal ID Universal Code ID Universal Length 5 Universal Terminal ID Actual Code ID Actual Leng...

Страница 78: ...k cover to program the scan engine for your terminal ID you must enter 3 digits For example scan 0 0 3 for an AT wedge Note 099 indicates all terminal types Step 4 Code I D In the Symbology Charts beginning on page 171 find the symbology to which you want to apply the data format Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart inside the back cover...

Страница 79: ...e format scan 1 2 or 3 depending on the format you are clearing Scan the Terminal Type and Code I D see Symbology Charts on page 171 and the bar code data length for the specific data format that you want to delete All other formats remain unaffected Clear all Data Formats This clears all data formats Save to exit and save your data format changes Discard to exit without saving any data format cha...

Страница 80: ...end a Number of Characters Include in the output message a number of characters followed by an insert char acter Start from the current cursor position and continue for nn characters or through the last character in the input message followed by character xx Syntax F2nnxx where nn stands for the numeric value 00 99 for the number of charac ters and xx stands for the insert character s hex value fo...

Страница 81: ...er ss followed by an insert character The cursor is moved for ward to the ss character Syntax F3ssxx where ss stands for the search charac ter s hex value for its ASCII code and xx stands for the insert character s hex value for its ASCII code Refer to the ASCII Conversion Chart Code Page 1252 beginning on page 174 for decimal hex and character codes Example Send all characters up to a particular ...

Страница 82: ...position Syntax F4xxnn where xx stands for the insert character s hex value for its ASCII code and nn is the numeric value 00 99 for the number of times it should be sent Refer to the ASCII Conversion Chart Code Page 1252 beginning on page 174 for decimal hex and character codes Example Send all but the last characters followed by 2 tabs E9 and F4 Send all characters except for the last 8 from the...

Страница 83: ...acters Move the cursor back nn characters from current cursor position Syntax F6nn where nn is the numeric value 00 99 for the number of characters the cursor should be moved back F7 Move the cursor to the beginning Move the cursor to the first character in the input message Syntax F7 Example Manipulate bar codes that begin with a 1 FE and F7 Search for bar codes that begin with a 1 If a bar code ...

Страница 84: ...or its ASCII code Refer to the ASCII Conversion Chart Code Page 1252 beginning on page 174 for decimal hex and character codes Example Send bar code data that starts after a particular character Search for the letter D in bar codes and send all the data that follows including the D Using the bar code above Command string F844F10D The data is output as DEFGHIJ CR F7 Move the cursor to the beginning...

Страница 85: ...e 174 for decimal hex and character codes Example Remove zeroes at the beginning of bar code data This example shows a bar code that has been zero filled You may want to ignore the zeroes and send all the data that follows E6 searches forward for the first char acter that is not zero then sends all the data after followed by a carriage return Using the bar code above Command string E630F10D The da...

Страница 86: ...nding the data Using the bar code above Command string FB0120F10D The data is output as 34567890 CR FC Stop suppressing characters Disables suppress filter and clear all suppressed characters Syntax FC E4 Replace characters Replaces up to 15 characters in the output message without moving the cursor Replacement continues until the E5 command is encountered Syntax E4nnxx 1xx2yy1yy2 zz1zz2 where nn ...

Страница 87: ... value for its ASCII code Refer to the ASCII Conversion Chart Code Page 1252 beginning on page 174 for decimal hex and character codes EC Check for a number Check to make sure there is an ASCII number at the current cursor position The format is aborted if the character is not numeric Example Only output the data if the bar code begins with a number If you want only data from bar codes that begin ...

Страница 88: ...If you want only data from bar codes that begin with a letter you can use ED to check for the letter Command string EDF10D If this bar code is read the next data format if there is one will be used on this data If there is no other format the format fails and the raw data is output as 1234AB If this bar code is read the data is output as AB1234 CR EF Insert a delay Inserts a delay of up to 49 995 ...

Страница 89: ...red Keep Prefix Suffix Scanned data is modified according to your data format and prefixes and suffixes are transmitted Any data that does not match your data format requirements generates an error tone and the data in that bar code is not transmitted If you wish to process this type of bar code without generating an error tone see Primary Alternate Data Formats Data Format Required Drop Prefix Su...

Страница 90: ...ese formats Your pri mary data format is saved under 0 Your other three formats are saved under 1 2 and 3 To set your device to use one of these formats scan one of the bar codes below Data Format Required Keep Prefix Suffix Data Format Required Drop Prefix Suffix Primary Data Format Data Format 1 Data Format 2 Data Format 3 ...

Страница 91: ...dabar MicroPDF417 Codablock A MSI Codablock F NEC 2 of 5 Code 11 Postal Codes 2D Code 128 Postal Codes Linear Code 32 Pharmaceutical PARAF PDF417 Code 39 GS1 DataBar Omnidirectional Code 93 QR Code Data Matrix Straight 2 of 5 IATA two bar start stop EAN JAN 13 Straight 2 of 5 Industrial three bar start stop EAN JAN 8 TCIF Linked Code 39 TLC39 GS1 Composite Codes UPC A GS1 DataBar Expanded UPC A EA...

Страница 92: ...e symbologies You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data This helps reduce the chances of a mis read Example Decode only those bar codes with a count of 9 20 characters Min length 09Max length 20 Example Decode only those bar codes with a count of 15 characters Min length 15Max length 15 For a value other than the minim...

Страница 93: ... 16 check characters Default No Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character When Check Character is set to Validate and Transmit the scanner will only read Codabar bar codes printed with a check character and will transmit this character at the end of the scanned data When Check Character is set to Validate but D...

Страница 94: ...elect Require to prevent the scanner from decoding a single D Codabar symbol without its companion This selection has no effect on Codabar symbols without Stop Start D characters Codabar Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 76 for additional information Minimum and Maximum lengths 2 60 Minimum Default 4 Maximum Default 60 Val...

Страница 95: ...it Start Stop characters Default Don t Trans mit Code 39 Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character When Check Character is set to Validate but Don t Transmit the unit only reads Code 39 bar codes printed with a check character but will not transmit the check character with the scanned data Maximum Message Lengt...

Страница 96: ...d Maximum lengths 0 48 Minimum Default 0 Maximum Default 48 Code 39 Append This function allows the scanner to append the data from several Code 39 bar codes together before transmitting them to the host computer When the scanner encounters a Code 39 bar code with the append trigger character s it buffers Code 39 bar codes until it reads a Code 39 bar code that does not have the append trigger The...

Страница 97: ...cter pairs M and N decode as a minus sign and period respectively Character pairs P through Y decode as 0 through 9 On Off NUL U DLE P SP SPACE 0 0 V P P W p P SOH A DC1 Q A 1 1 A A Q Q a A q Q STX B DC2 R B 2 2 B B R R b B r R ETX C DC3 S C 3 3 C C S S c C s S EOT D DC4 T D 4 4 D D T T d D t T ENQ E NAK U E 5 5 E E U U e E u U ACK F SYN V F 6 6 F F V V f F v V BEL G ETB W G 7 7 G G W W g G w W BS...

Страница 98: ... 2022 ISO 646 Character Replacements on page 180 and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual The data characters should then appear properly Interleaved 2 of 5 Default All Interleaved 2 of 5 Settings Interleaved 2 of 5 On Off Check Digit No Check Digit indicates that the scanner reads and transmits bar code data with or without a ...

Страница 99: ...fault No Check Digit Interleaved 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 76 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 NEC 2 of 5 Default All NEC 2 of 5 Settings NEC 2 of 5 On Off No Check Digit Validate but Don t Transmit Validate and Transmit Minimum Message Length M...

Страница 100: ...is set to Validate and Transmit the scanner only reads NEC 2 of 5 bar codes printed with a check digit and will transmit this digit at the end of the scanned data Default No Check Digit NEC 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 76 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Defa...

Страница 101: ...Code 93 bar codes together before transmitting them to the host computer When this function is enabled the scanner stores those Code 93 bar codes that start with a space excluding the start and stop symbols and does not immediately transmit the data The scanner stores the data in the order in which the bar codes are read deleting the first space from each The scanner transmits the appended data wh...

Страница 102: ... 646 Character Replacements on page 180 and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual The data characters should then appear properly Straight 2 of 5 Industrial three bar start stop Default All Straight 2 of 5 Industrial Settings Straight 2 of 5 Industrial On Off Straight 2 of 5 Industrial Message Length Scan the bar codes below to ...

Страница 103: ...ght 2 of 5 IATA Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 76 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 Matrix 2 of 5 Default All Matrix 2 of 5 Settings Matrix 2 of 5 On Off On Off Minimum Message Length Maximum Message Length On ...

Страница 104: ...below to change the message length Refer to Message Length Description page 76 for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 Code 11 Default All Code 11 Settings Code 11 On Off Off Minimum Message Length Maximum Message Length On Off ...

Страница 105: ...ts Code 11 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 76 for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 Code 128 Default All Code 128 Settings Code 128 On Off One Check Digit Two Check Digits Minimum Message Length Maximum Message Length On Off ...

Страница 106: ...lood product label Use the bar codes below to turn concatenation on or off Default Off Code 128 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 76 for additional information Minimum and Maximum lengths 0 80 Minimum Default 0 Maximum Default 80 Code 128 Append This function allows the scanner to append the data from several Code 128 bar ...

Страница 107: ...hat is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 646 Character Replacements on page 180 and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual The data characters should then appear properly GS1 128 Default All G...

Страница 108: ... Maximum lengths 1 80 Minimum Default 1 Maximum Default 80 UPC A Default All UPC A Settings UPC A On Off Note To convert UPC A bar codes to EAN 13 see Convert UPC A to EAN 13 on page 98 UPC A Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On Minimum Message Length Maximum Message Length On Off On Off ...

Страница 109: ...t On UPC A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC A data Default Off for both 2 Digit and 5 Digit Addenda UPC A Addenda Required When Required is scanned the scanner will only read UPC A bar codes that have addenda You must then turn on a 2 or 5 digit addenda listed on page 93 Default Not Required On Off 2 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On 5 D...

Страница 110: ...Off the scanner treats Coupon Codes and Extended Coupon Codes as single bar codes If you scan the Allow Concatenation code when the scanner sees the coupon code and the extended coupon code in a single scan it transmits both as one sym bology Otherwise it transmits the first coupon code it reads If you scan the Require Concatenation code the scanner must see and read the coupon code and extended c...

Страница 111: ...utput only the GS1 DataBar code data Default GS1 Output Off UPC E0 Default All UPC E Settings UPC E0 On Off Most U P C bar codes lead with the 0 number system To read these codes use the UPC E0 On selection If you need to read codes that lead with the 1 number sys tem use UPC E1 page 97 Default On UPC E0 Expand UPC E Expand expands the UPC E code to the 12 digit UPC A format Default Off GS1 Output...

Страница 112: ...equired UPC E0 Addenda Separator When this feature is On there is a space between the data from the bar code and the data from the addenda When turned Off there is no space Default On UPC E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not Default On Off Required Not Required On Off On Off ...

Страница 113: ...his selection adds 2 or 5 digits to the end of all scanned UPC E data Default Off for both 2 Digit and 5 Digit Addenda UPC E1 Most U P C bar codes lead with the 0 number system For these codes use UPC E0 page 95 If you need to read codes that lead with the 1 number system use the UPC E1 On selection Default Off On Off 2 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On 5 Digit Addenda Off UP...

Страница 114: ... Off Convert UPC A to EAN 13 When UPC A Converted to EAN 13 is selected UPC A bar codes are converted to 13 digit EAN 13 codes by adding a zero to the front When Do not Convert UPC A is selected UPC A codes are read as UPC A UPC E1 Off On Off UPC A Converted to EAN 13 Do not Convert UPC A ...

Страница 115: ... EAN JAN 13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN JAN 13 data Default Off for both 2 Digit and 5 Digit Addenda EAN JAN 13 Addenda Required When Required is scanned the scanner will only read EAN JAN 13 bar codes that have addenda Default Not Required On Off 2 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On 5 Digit Addenda Off Required Not Required ...

Страница 116: ...en turned Off there is no space Default On Note If you want to enable or disable EAN13 with Extended Coupon Code refer to UPC A EAN 13 with Extended Coupon Code page 94 ISBN Translate When On is scanned EAN 13 Bookland symbols are translated into their equiva lent ISBN number format Default Off EAN JAN 8 Default All EAN JAN 8 Settings EAN JAN 8 On Off On Off On Off On Off ...

Страница 117: ...On EAN JAN 8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN JAN 8 data Default Off for both 2 Digit and 5 Digit Addenda EAN JAN 8 Addenda Required When Required is scanned the scanner will only read EAN JAN 8 bar codes that have addenda Default Not Required On Off 2 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On 5 Digit Addenda Off Required Not Required ...

Страница 118: ... On Off MSI Check Character Different types of check characters are used with MSI bar codes You can program the scanner to read MSI bar codes with Type 10 check characters Default Validate Type 10 but Don t Transmit When Check Character is set to Validate Type 10 11 and Transmit the scanner will only read MSI bar codes printed with the specified type check character s and will transmit the charact...

Страница 119: ...hange the message length Refer to Message Length Description page 76 for additional information Minimum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 Validate Type 10 but Don t Transmit Validate Type 10 and Transmit Validate 2 Type 10 Characters but Don t Transmit Validate 2 Type 10 Characters and Transmit Validate Type 11 then Type 10 Character but Don t Transmit Validate Type 11 ...

Страница 120: ...ectional Default All GS1 DataBar Omnidirectional Settings GS1 DataBar Omnidirectional On Off GS1 DataBar Limited Default All GS1 DataBar Limited Settings GS1 DataBar Limited On Off GS1 DataBar Expanded Default All GS1 DataBar Expanded Settings On Off On Off ...

Страница 121: ... bar codes below to change the message length Refer to Message Length Description page 76 for additional information Minimum and Maximum lengths 4 74 Minimum Default 4 Maximum Default 74 Codablock A Default All Codablock A Settings Codablock A On Off On Off Minimum Message Length Maximum Message Length On Off ...

Страница 122: ...inimum Default 1 Maximum Default 600 Codablock F Default All Codablock F Settings Codablock F On Off Codablock F Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 76 for additional information Minimum and Maximum lengths 1 2048 Minimum Default 1 Maximum Default 2048 Minimum Message Length Maximum Message Length On Off Minimum Message Leng...

Страница 123: ...76 for additional information Minimum and Maximum lengths 1 2750 Minimum Default 1 Maximum Default 2750 MacroPDF417 MacroPDF417 is an implementation of PDF417 capable of encoding very large amounts of data into multiple PDF417 bar codes When this selection is enabled these multiple bar codes are assembled into a single data string Default On On Off Minimum Message Length Maximum Message Length On ...

Страница 124: ...h Description page 76 for additional information Minimum and Maximum lengths 1 366 Minimum Default 1 Maximum Default 366 GS1 Composite Codes Linear codes are combined with a unique 2D composite component to form a new class called GS1 Composite symbology GS1 Composite symbologies allow for the co existence of symbologies already in use Default Off On Off Minimum Message Length Maximum Message Leng...

Страница 125: ... Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 76 for additional information Minimum and Maximum lengths 1 2435 Minimum Default 1 Maximum Default 2435 GS1 Emulation The scanner can automatically format the output from any GS1 data carrier to emulate what would be encoded in an equivalent GS1 128 or GS1 DataBar symbol GS1 data carriers...

Страница 126: ...n is controlled by the UPC E0 Expand page 95 setting If the AIM ID is enabled the value will be the GS1 128 AIM ID C1 see Symbology Charts on page 171 If EAN8 to EAN13 Conversion is scanned all EAN8 bar codes are converted to EAN13 format Default GS1 Emulation Off TCIF Linked Code 39 TLC39 This code is a composite code since it has a Code 39 linear component and a MicroPDF417 stacked code componen...

Страница 127: ...age Length Description page 76 for additional information Minimum and Maximum lengths 1 7089 Minimum Default 1 Maximum Default 7089 QR Code Append This function allows the scanner to append the data from several QR Code bar codes together before transmitting them to the host computer When the scanner encounters an QR Code bar code with the append trigger character s it buffers Off On Off Minimum M...

Страница 128: ...r one time for each image The scanner emits a short beep for each partial QR Code that is scanned and buffered One long beep is emitted after the last QR Code is scanned and the data is complete Not compatible with Presentation mode Default One Scan QR Code Page QR Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may...

Страница 129: ... to characters If the data received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 646 Character Replacements on page 180 and scan the value and th...

Страница 130: ...h Scan the bar codes below to change the message length Refer to Message Length Description page 76 for additional information Minimum and Maximum lengths 1 150 Minimum Default 1 Maximum Default 150 Aztec Code Default All Aztec Code Settings Aztec Code On Off On Off Minimum Message Length Maximum Message Length On ...

Страница 131: ...put in the order speci fied in the bar codes There are 3 ways to scan appended Aztec Code One scan Pull the trigger one time and all appended Aztec Codes in the same image are decoded Swipe Pull and hold down the trigger and scan all appended Aztec Codes while keeping the trigger pressed The scanner emits short beeps for each partial Aztec Code that is scanned and buffered One long beep is emitted...

Страница 132: ... the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 646 Character Replacements on page 180 and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual The data characters should then appear properly Chinese Sensible Han Xin Code Default All ...

Страница 133: ...t 7833 Postal Codes 2D The following lists the possible 2D postal codes and 2D postal code combinations that are allowed Only one 2D postal code selection can be active at a time If you scan a second 2D postal code selection the first selection is overwritten Default 2D Postal Codes Off Single 2D Postal Codes Minimum Message Length Maximum Message Length 2D Postal Codes Off Australian Post On Brit...

Страница 134: ...2D Postal Codes Japanese Post On KIX Post On Planet Code On Also see Planet Postal 4i On Postnet On Also see Postnet Postnet with B and B Fields On InfoMail On InfoMail and British Post On Intelligent Mail Bar Code and Postnet with B and B Fields On ...

Страница 135: ... and Intelligent Mail Bar Code On Postal 4i and Postnet with B and B Fields On Planet Code and Postnet On Planet Code and Postnet with B and B Fields On Planet Code and Postal 4i On Planet Code and Intelligent Mail Bar Code Planet Code Postnet and Postal 4i On Planet Code Postnet and Intelligent Mail Bar Code On ...

Страница 136: ... Mail Bar Code On Postnet Postal 4i and Intelligent Mail Bar Code On Planet Code Postal 4i and Postnet with B and B Fields On Planet Code Intelligent Mail Bar Code and Postnet with B and B Fields On Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On Planet Code Postal 4i Intelligent Mail Bar Code and Postnet On Planet Code Postal 4i Intelligent Mail Bar Code and Postnet with B ...

Страница 137: ...State symbols Bar Output lists the bar patterns in 0123 format Numeric N Table causes that field to be interpreted as numeric data using the N Table Alphanumeric C Table causes the field to be interpreted as alphanumeric data using the C Table Refer to the Australian Post Specification Tables Combination C and N Tables causes the field to be interpreted using either the C or N Tables Don t Transmi...

Страница 138: ...efault All China Post Hong Kong 2 of 5 Settings China Post Hong Kong 2 of 5 On Off China Post Hong Kong 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 76 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 Combination C and N Tables On Off Minimum Message Length Maximum Message Length...

Страница 139: ...gth Refer to Message Length Description page 76 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 Korea Post Check Digit This selection allows you to specify whether the check digit should be transmitted Default Don t Transmit On Off Minimum Message Length Maximum Message Length Transmit Check Digit Don t Transmit Check Digit ...

Страница 140: ...124 N3680 Decoded Engine User Guide ...

Страница 141: ...hange a setting you must use the serial default commands see Chapter 9 When the serial default command is used that selection becomes the new permanent setting for the scan engine Command Syntax Multiple modifiers and commands can be issued within one sequence If additional modifiers are to be applied to the same command just add the modifiers to that command For example to add 2 modifiers to the ...

Страница 142: ...command is processed The image snap command has many different modifiers that can be used to change the look of the image in memory Any number of modifiers may be appended to the IMGSNP command For example you can use the following com mand to snap an image increase the gain and have the beeper sound once the snap is complete IMGSNP2G1B IMGSNP Modifiers P Imaging Style This sets the Image Snap sty...

Страница 143: ...E Exposure Exposure is used in Manual Style only 2P and allows you to set the exposure time This is similar to setting a shutter speed on a camera The exposure time determines how long the scanner takes to record an image On a bright day expo sure times can be very short because plenty of light is available to help record an image At nighttime exposure time can increase dramatically due to the nea...

Страница 144: ...er setting such as 75 is recom mended Higher settings result in longer exposure times and brighter images but if the setting is too high the image may be overexposed Target White Value is only available when using Photo Style 1P Default 90 Example D Delta for Acceptance This sets the allowable range for the white value setting see W Target White Value Delta is only available when using Photo Style...

Страница 145: ...ed Default 50 Example Step 2 Ship a Picture Using IMGSHP Image Ship IMGSHP An image is taken whenever the button is pressed or when the Image Snap IMGSNP command is processed The last image is always stored in memory You can ship the image by using the IMGSHP command The image ship commands have many different modifiers that can be used to change the look of the image output Modifiers affect the i...

Страница 146: ... for variations in illumination across the image Example D Pixel Depth Indicates the number of bits per pixel in the transmitted image KIM or BMP format only 0A Infinity filter off default 1A Infinity filter on Infinity Filter off 0A from approximately 12 feet 3 66m away Infinity Filter on 1A from approximately 12 feet 3 66m away 0C Compensation disabled default 1C Compensation enabled Compensatio...

Страница 147: ...e Example F File Format Indicates the desired format for the image 1D 1 bit per pixel black and white image 0E Don t sharpen image default 14E Apply edge sharpen for typical image ne Apply edge sharpen using strength n n 1 24 Edge Sharpen at 0E Edge Sharpen at 24E 0F KIM format 1F TIFF binary 2F TIFF binary group 4 compressed 3F TIFF grayscale 4F Uncompressed binary upper left to lower right 1 pix...

Страница 148: ...e Invert image is used to rotate the image around the X or Y axis Example 0H No stretch default 1H Histogram stretch Histogram Stretch at 0H Histogram Stretch at 1H 1ix Invert around the X axis flips picture upside down 1iy Invert around the Y axis flips picture left to right Image with Invert Image set to 1ix Image not inverted Image with Invert Image set to 1iy ...

Страница 149: ...r noise reduction default 1if Salt and pepper noise reduction Reduction On 1if Noise Reduction Off 0if 0ir Image as snapped rightside up default 1ir Rotate image 90 degrees to the right 2ir Rotate image 180 degrees upside down 3ir Rotate image 90 degrees to the left Image Rotate set to 0ir Image Rotate set to 2ir Image Rotate set to 1ir Image Rotate set to 3ir ...

Страница 150: ...image You can brighten or darken an image using gamma correction A higher gamma correc tion yields an overall brighter image The lower the setting the darker the image The optimal setting for text images is 50K Example nJ Image is compressed as much as possible while preserving quality factor of n n 0 100 0J Worst quality smallest file 100J Best quality largest file 0K Gamma correction off default...

Страница 151: ... Default 0 nR The right edge of the shipped image corresponds to column n 1 of the image in memory Range 000 843 Default all columns nT The top edge of the shipped image corresponds to row n of the image in memory Range 000 639 Default 0 nB The bottom edge of the shipped image corresponds to row n 1 of the image in memory Range 000 639 Default all rows Image Crop set to 300L Image Crop set to 300R...

Страница 152: ...y fourth line The smaller number of pixels shipped the smaller the image however after a certain point the image becomes unusable Example U Document Image Filter Allows you to input parameters to sharpen the edges and smooth the area between the edges of text in an image This filter should be used with gamma correction see page 134 with the scan engine in a stand and the image captured using the c...

Страница 153: ...ng the pixels next to the hard edges of defined lines and shaded areas in an image Example 0U Document image filter off default 26U Apply document image filter for typical document image nU Apply document image filter using grayscale threshold n Use lower numbers when the image contrast is lower 1U will have a similar effect to setting E Edge Sharpen page 131 to 22e Range 0 255 Document Image Filt...

Страница 154: ...low key image has detail concentrated in the shadows a high key image has detail concentrated in the highlights and an average key image has detail concentrated in the midtones This modifier ships the histogram for an image Example 0W Don t ship histogram default 1W Ship histogram Image used for histogram Histogram of image at left ...

Страница 155: ...s each symbology This action first clears all current prefixes then programs a Code I D prefix for all symbologies This is a temporary setting that will be removed when the unit is power cycled Show Decoder Revision Scan the bar code below to output the decoder revision Show Scan Driver Revision Scan the bar code below to output the scan driver revision The scan driver controls image capture Add C...

Страница 156: ...n the content of that program ming code is output to the terminal Note This feature should not be used during normal scan engine operation EZConfig Cloud Introduction EZConfig Cloud provides a wide range of PC based programming functions that can be performed on a scan engine connected to your PC s COM port EZConfig Cloud allows you to download upgrades to the scan engine s firmware change pro gra...

Страница 157: ... with the parameters form belonging to that particular cate gory The Configure tree option has all the programming and configuration parameters specified for a scan engine You can set or modify these parameters as required You can later write the modified settings to the scan engine or save them to a dcf file Imaging Imaging provides all the image related functions that a 2D scan engine can per fo...

Страница 158: ... Remove Custom Defaults bar code then scan Activate Defaults This resets the scan engine to the factory default settings The Menu Commands beginning on page 148 list the factory default settings for each of the commands indicated by an asterisk on the programming pages Caution This selection erases all your settings and resets the scan engine to the original factory defaults It also disables all p...

Страница 159: ... corresponding programming bar code in this manual The device must be set to an RS232 interface see page 7 The following com mands can be sent via a PC COM port using terminal emulation software Conventions The following conventions are used for menu and query command descriptions parameter A label representing the actual value you should send as part of a command option An optional part of a comm...

Страница 160: ...le all RS 232 configuration settings are identified with a Tag of 232 SubTag A 3 character case insensitive field that identifies the desired menu command within the tag group For example the SubTag for the RS 232 baud rate is BAD Data The new value for a menu setting identified by the Tag and SubTag Storage A single character that specifies the storage table to which the command is applied exclam...

Страница 161: ... sequence If additional commands are to be applied to the same Tag then the new command sequence is separated with a comma and only the SubTag and Data fields of the additional command are issued If the additional command requires a different Tag field the command is separated from previous commands by a semicolon Responses The device responds to serial commands with one of three responses When re...

Страница 162: ... or on Example What are the device s settings for all Codabar selections This response indicates that the device s Codabar Coding Enable CBRENA is set To 1 or on The Start Stop Character SSX is set to 0 or Don t Transmit The Check Character CK2 is set to 0 or Not Required Concatenation CCT is set to 1 or Enabled The Minimum Message Length MIN is set to 2 characters The Maximum Message Length MAX i...

Страница 163: ...re custom defaults in your product MNUCDF DEFOVR CMD1 CMD2 CMDX MNUCDS The custom defaults are not applied immediately to activate send the Activate Defaults command or read the DEFALT bar code below Resetting the Custom Defaults If you want the custom default settings restored to your scan engine scan the Acti vate Custom Defaults bar code below This resets the scan engine to the custom default s...

Страница 164: ... ACK NAK Mode On USBACK1 9 ACK NAK Mode Off USBACK0 9 Plug and Play Codes Verifone Ruby Terminal PAPRBY 9 Gilbarco Terminal PAPGLB 9 Honeywell Bioptic Aux Port PAPBIO 10 Datalogic Magellan Bioptic Aux Port PAPMAG 10 NCR Bioptic Aux Port PAPNCR 10 Wincor Nixdorf Terminal PAPWNX 11 Wincor Nixdorf Beetle PAPBTL 11 Wincor Nixdork RS232 Mode A PAPWMA 12 Program Keyboard Country U S A KBDCTY0 12 Albania...

Страница 165: ...KBDCTY61 14 Greek 319 Latin KBDCTY65 14 Greek 319 KBDCTY62 14 Greek Latin KBDCTY63 15 Greek MS KBDCTY66 15 Greek Polytonic KBDCTY60 15 Hebrew KBDCTY12 15 Hungarian 101 key KBDCTY50 15 Hungary KBDCTY19 15 Iceland KBDCTY75 15 Irish KBDCTY73 15 Italian 142 KBDCTY56 15 Italy KBDCTY5 15 Japan ASCII KBDCTY28 15 Kazakh KBDCTY78 15 Kyrgyz Cyrillic KBDCTY79 16 Latin America KBDCTY14 16 Latvia KBDCTY42 16 L...

Страница 166: ...Y31 18 Spain KBDCTY10 18 Spanish variation KBDCTY51 18 Sweden KBDCTY23 18 Switzerland French KBDCTY29 18 Switzerland German KBDCTY6 18 Tatar KBDCTY85 18 Turkey F KBDCTY27 18 Turkey Q KBDCTY24 18 Ukrainian KBDCTY76 18 United Kingdom KBDCTY7 18 United Stated Dvorak right KBDCTY89 19 United States Dvorak left KBDCTY88 19 United States Dvorak KBDCTY87 18 United States International KBDCTY30 19 Uzbek C...

Страница 167: ...1 22 Auto Direct Connect Off KBDADC0 23 Auto Direct Connect On KBDADC1 22 Baud Rate 300 BPS 232BAD0 23 600 BPS 232BAD1 23 1200 BPS 232BAD2 23 2400 BPS 232BAD3 23 4800 BPS 232BAD4 23 9600 BPS 232BAD5 23 19200 BPS 232BAD6 23 38400 BPS 232BAD7 23 57600 BPS 232BAD8 24 115200 BPS 232BAD9 24 Word Length Data Bits Stop Bits and Parity 7 Data 1 Stop Parity Even 232WRD3 24 7 Data 1 Stop Parity None 232WRD0...

Страница 168: ...CK NAK On 232NAK1 28 Scanner Bioptic ACK NAK Timeout ACK NAK Timeout 5100 232DLK 28 Input Output Selections Power Up Beeper Power Up Beeper Off Scanner BEPPWR0 29 Power Up Beeper On Scanner BEPPWR1 29 Beep on BEL Character Beep on BEL On BELBEP1 29 Beep on BEL Off BELBEP0 29 Trigger Click On BEPTRG1 30 Off BEPTRG0 30 Beeper Good Read Off BEPBEP0 30 On BEPBEP1 30 Beeper Volume Good Read Off BEPLVL0...

Страница 169: ...50 37 High N3680 default PWRNOL150 34 Character Activation Mode Off HSTCEN0 34 On HSTCEN1 34 Activation Character 12 DC2 HSTACH 35 End Character Activation After Good Read Do Not End HSTCGD0 35 End HSTCGD1 35 Character Activation Timeout Range 1 300 000 milliseconds 30 000 ms HSTCDT 35 Character Deactivation Mode Off HSTDEN0 36 On HSTDEN1 36 Deactivation Character 14 DC4 HSTDCH 36 Serial Trigger M...

Страница 170: ...Medium 2000ms DLY2RR2000 44 Long 3000ms DLY2RR3000 44 Extra Long 4000ms DLY2RR4000 44 Illumination Lights Lights On SCNLED1 44 Lights Off SCNLED0 44 Aimer Delay 200 milliseconds SCNDLY200 45 400 milliseconds SCNDLY400 45 Off no delay SCNDLY0 45 User Specified Aimer Delay Range 0 4 000 ms SCNDLY 45 Aimer Mode Off CF3680 default SCNAIM0 45 Interlaced N3680 default SCNAIM2 45 Interlaced Optimized for...

Страница 171: ...Prefix PREBK2 57 Clear One Prefix PRECL2 57 Clear All Prefixes PRECA2 57 Suffix Add Suffix SUFBK2 58 Clear One Suffix SUFCL2 58 Clear All Suffixes SUFCA2 58 Function Code Transmit Enable RMVFNC0 58 Disable RMVFNC1 58 Intercharacter Delay Range 0 1000 5ms increments DLYCHR 59 User Specified Intercharacter Delay Delay Length 0 1000 5ms increments DLYCRX 59 Character to Trigger Delay DLY_XX 59 Interf...

Страница 172: ...odabar Settings CBRDFT 76 Off CBRENA0 77 On CBRENA1 77 Codabar Start Stop Char Don t Transmit CBRSSX0 77 Transmit CBRSSX1 77 Codabar Check Char No Check Character CBRCK20 77 Validate Modulo 16 But Don t Transmit CBRCK21 78 Validate Modulo 16 and Transmit CBRCK22 78 Codabar Concatenation Off CBRCCT0 78 On CBRCCT1 78 Require CBRCCT2 78 Codabar Message Length Minimum 2 60 4 CBRMIN 78 Maximum 2 60 60 ...

Страница 173: ...2 80 4 I25MIN 83 Maximum 2 80 80 I25MAX 83 NEC 2 of 5 Default All NEC 2 of 5 Settings N25DFT 83 Off N25ENA0 83 On N25ENA1 83 NEC 2 of 5 Check Digit No Check Char N25CK20 84 Validate But Don t Transmit N25CK21 84 Validate and Transmit N25CK22 84 NEC 2 of 5 Message Length Minimum 2 80 4 N25MIN 84 Maximum 2 80 80 N25MAX 84 Code 93 Default All Code 93 Settings C93DFT 84 Off C93ENA0 85 On C93ENA1 85 Co...

Страница 174: ...1 88 Code 11 Check Digits Required 1 Check Digit C11CK20 89 2 Check Digits C11CK21 89 Code 11 Message Length Minimum 1 80 4 C11MIN 89 Maximum 1 80 80 C11MAX 89 Code 128 Default All Code 128 Settings 128DFT 89 Off 128ENA0 89 On 128ENA1 89 ISBT Concatenation Off ISBENA0 90 On ISBENA1 90 Code 128 Message Length Minimum 0 80 0 128MIN 90 Maximum 0 90 80 128MAX 90 Code 128 Append On 128APP1 90 Off 128AP...

Страница 175: ... 94 Coupon GS1 DataBar Output GS1 Output Off CPNGS10 95 GS1 Output On CPNGS11 95 UPC E0 Default All UPC E Settings UPEDFT 95 Off UPEEN00 95 On UPEEN01 95 UPC E0 Expand Off UPEEXP0 95 On UPEEXP1 95 UPC E0 Addenda Required Required UPEARQ1 96 Not Required UPEARQ0 96 UPC E0 Addenda Separator On UPEADS1 96 Off UPEADS0 96 UPC E0 Check Digit Off UPECKX0 96 On UPECKX1 96 UPC E0 Leading Zero Off UPENSX0 9...

Страница 176: ...Q1 99 EAN JAN 13 Addenda Separator Off E13ADS0 100 On E13ADS1 100 ISBN Translate Off E13ISB0 100 On E13ISB1 100 EAN JAN 8 Default All EAN JAN 8 Settings EA8DFT 100 Off EA8ENA0 100 On EA8ENA1 100 EAN JAN 8 Check Digit Off EA8CKX0 101 On EA8CKX1 101 EAN JAN 8 Addenda 2 Digit Addenda Off EA8AD20 101 2 Digit Addenda On EA8AD21 101 5 Digit Addenda On EA8AD51 101 5 Digit Addenda Off EA8AD50 101 EAN JAN ...

Страница 177: ... RSSENA1 104 GS1 DataBar Limited Default All GS1 DataBar Limited Settings RSLDFT 104 Off RSLENA0 104 On RSLENA1 104 GS1 DataBar Expanded Default All GS1 DataBar Expanded Settings RSEDFT 104 Off RSEENA0 105 On RSEENA1 105 GS1 DataBar Expanded Msg Length Minimum 4 74 4 RSEMIN 105 Maximum 4 74 74 RSEMAX 105 Codablock A Default All Codablock A Settings CBADFT 105 Off CBAENA0 105 On CBAENA1 105 Codablo...

Страница 178: ... EANEMU1 110 GS1 DataBar Emulation EANEMU2 110 GS1 Code Expansion Off EANEMU3 110 EAN8 to EAN13 Conversion EANEMU4 110 GS1 Emulation Off EANEMU0 110 TCIF Linked Code 39 On T39ENA1 110 Off T39ENA0 110 QR Code Default All QR Code Settings QRCDFT 111 On QRCENA1 111 Off QRCENA0 111 QR Code Msg Length Minimum 1 7089 1 QRCMIN 111 Maximum 1 7089 7089 QRCMAX 111 QR Code Append One Scan QRCAPP1 111 Swipe Q...

Страница 179: ...e Settings HX_DFT 116 On HX_ENA1 116 Off HX_ENA0 116 Chinese Sensible Han Xin Code Msg Length Minimum 1 7833 1 HX_MIN 117 Maximum 1 7833 7833 HX_MAX 117 Postal Codes 2D 2D Postal Codes Off POSTAL0 117 Single 2D Postal Codes Australian Post On POSTAL1 117 British Post On POSTAL7 117 Canadian Post On POSTAL30 117 Intelligent Mail Bar Code On POSTAL10 117 Japanese Post On POSTAL3 118 KIX Post On POST...

Страница 180: ...elds On POSTAL25 120 Planet Intelligent Mail Bar Code and Postnet with B and B Fields On POSTAL26 120 Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On POSTAL27 120 Planet Postal 4i Intelligent Mail Bar Code and Postnet On POSTAL28 120 Planet Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On POSTAL29 120 Planet Code Check Digit Transmit PLNCKX1 120 Don t T...

Страница 181: ...r Off SNPBEP0 126 Wait for Trigger Off SNPTRG0 127 Wait for Trigger On SNPTRG1 127 LED State Off SNPLED0 127 LED State On SNPLED1 127 Exposure 1 7874 microseconds SNPEXP 127 Gain None SNPGAN1 128 Gain Medium SNPGAN2 128 Gain Heavy SNPGAN4 128 Gain Maximum SNPGAN8 128 Target White Value 0 255 125 SNPWHT 128 Delta for Acceptance 0 255 25 SNPDEL 128 Update Tries 0 10 6 SNPTRY 129 Target Set Point Per...

Страница 182: ...3 Rotate Image 180 right IMGROT2 133 Rotate Image 90 left IMGROT3 133 JPEG Image Quality 0 100 50 IMGJQF 134 Gamma Correction Off IMGGAM0 134 Gamma Correction On 0 1000 IMGGAM 134 Image Crop Left 0 640 0 IMGWNL 135 Image Crop Right 0 640 639 IMGWNR 135 Image Crop Top 0 480 0 IMGWNT 135 Image Crop Bottom 0 480 479 IMGWNB 135 Image Crop Margin 1 238 0 IMGMAR 135 Protocol None raw IMGXFR0 136 Protoco...

Страница 183: ...vision REV_DR 139 Show Scan Driver Revision REV_SD 139 Show Software Revision REVINF 140 Show Data Format DFMBK3 140 Test Menu On TSTMNU1 140 Off TSTMNU0 140 Resetting the Factory Defaults Remove Custom Defaults DEFOVR 142 Activate Defaults DEFALT 142 Selection Setting Indicates default Serial Command Indicates a numeric entry Page ...

Страница 184: ...168 N3680 Decoded Engine User Guide ...

Страница 185: ... Honeywell distributor for information about cable replace ment Troubleshooting The scan engine automatically performs self tests whenever you turn it on If your scan engine is not functioning properly review the following Troubleshooting Guide to try to isolate the problem Is the power on Is the red or green aiming illumination line on If the aiming line doesn t appear check that The cable is con...

Страница 186: ...ed for the appropriate terminal interface For example you scan 12345 and the host displays es Reprogram the scan engine with the correct Plug and Play or Terminal selection bar code See Chapter 2 and Chapter 3 The scan engine may not be programmed to output your bar code data properly For example you scan 12345 and the host displays A12345B Reprogram the scan engine with the proper symbology selec...

Страница 187: ...ng on page 55 and Data Formatting beginning on page 61 for information about using Code ID and AIM ID Linear Symbologies AIM Honeywell Symbology ID Possible modifiers m ID Hex All Symbologies 99 Codabar Fm 0 1 a 61 Code 11 H3 h 68 Code 128 Cm 0 1 2 4 j 6A Code 32 Pharmaceutical PARAF X0 3C Code 39 supports Full ASCII mode Am 0 1 3 4 5 7 b 62 TCIF Linked Code 39 TLC39 L2 T 54 Code 93 and 93i Gm 0 9...

Страница 188: ... 2 of 5 X0 m 6D NEC 2 of 5 X0 Y 59 Straight 2 of 5 IATA Rm 0 1 3 f 66 Straight 2 of 5 Industrial S0 f 66 MSI Mm 0 1 g 67 Telepen Bm t 74 UPC 0 1 2 3 8 9 A B C UPC A E0 c 63 UPC A with Add On E3 c 63 UPC A with Extended Coupon Code E3 c 63 UPC E E0 E 45 UPC E with Add On E3 E 45 UPC E1 X0 E 45 Add Honeywell Code ID 5C80 Add AIM Code ID 5C81 Add Backslash 5C5C Batch mode quantity 5 35 AIM Honeywell ...

Страница 189: ...w 77 GS1 em 0 3 y 79 GS1 Composite em 0 3 y 79 GS1 DataBar Omnidirectional em y 79 MaxiCode Um 0 3 x 78 PDF417 Lm 0 2 r 72 MicroPDF417 Lm 0 5 R 52 QR Code Qm 0 6 s 73 Micro QR Code Qm s 73 AIM Honeywell Symbology ID Possible modifiers m ID Hex All Symbologies 99 Australian Post X0 A 41 British Post X0 B 42 Canadian Post X0 C 43 China Post X0 Q 51 InfoMail X0 2c Intelligent Mail Bar Code X0 M 4D Ja...

Страница 190: ...DEC HEX Char CTRL X CTRL X function 0 00 NUL Reserved CTRL 1 01 SOH NP Enter CTRL A Select all 2 02 STX Caps Lock CTRL B Bold 3 03 ETX ALT Make CTRL C Copy 4 04 EOT ALT Break CTRL D Bookmark 5 05 ENQ CTRL Make CTRL E Center 6 06 ACK CTRL Break CTRL F Find 7 07 BEL Enter Ret CTRL G 8 08 BS Apple Make CTRL H History 9 09 HT Tab CTRL I Italic 10 0A LF Apple Break CTRL J Justify 11 0B VT Tab CTRL K hy...

Страница 191: ...trol X Mode On KBDCAS2 DEC HEX Char CTRL X CTRL X function Printable Characters DEC HEX Character DEC HEX Character DEC HEX Character 32 20 SPACE 64 40 96 60 33 21 65 41 A 97 61 a 34 22 66 42 B 98 62 b 35 23 67 43 C 99 63 c 36 24 68 44 D 100 64 d 37 25 69 45 E 101 65 e 38 26 70 46 F 102 66 f 39 27 71 47 G 103 67 g 40 28 72 48 H 104 68 h 41 29 73 49 I 105 69 i 42 2A 74 4A J 106 6A j 43 2B 75 4B K 1...

Страница 192: ...d DEC HEX Character DEC HEX Character DEC HEX Character Extended ASCII Characters DEC HEX CP 1252 ASCII Alternate Extended PS2 Scan Code 128 80 Ç up arrow 0x48 129 81 ü down arrow 0x50 130 82 é right arrow 0x4B 131 83 ƒ â left arrow 0x4D 132 84 ä Insert 0x52 133 85 à Delete 0x53 134 86 å Home 0x47 135 87 ç End 0x4F 136 88 ˆ ê Page Up 0x49 137 89 ë Page Down 0x51 138 8A Š è Right ALT 0x38 139 8B ï ...

Страница 193: ...A0 á Num Lock 0x45 161 A1 í Left Alt 0x38 162 A2 ó Left Ctrl 0x1D 163 A3 ú Left Shift 0x2A 164 A4 ñ Right Shift 0x36 165 A5 Ñ Print Screen n a 166 A6 ª Tab 0x0F 167 A7 º Shift Tab 0x8F 168 A8 Enter 0x1C 169 A9 Esc 0x01 170 AA ª Alt Make 0x36 171 AB Alt Break 0xB6 172 AC Control Make 0x1D 173 AD Control Break 0x9D 174 AE Alt Sequence with 1 Character 0x36 175 AF Ctrl Sequence with 1 Character 0x1D ...

Страница 194: ...BE 191 BF 192 C0 À 193 C1 Á 194 C2 Â 195 C3 Ã 196 C4 Ä 197 C5 Å í 198 C6 Æ 199 C7 Ç 200 C8 È 201 C9 É 202 CA Ê 203 CB Ë 204 CC Ì 205 CD Í 206 CE Î 207 CF Ï 208 D0 Ð 209 D1 Ñ 210 D2 Ò 211 D3 Ó 212 D4 Ô 213 D5 Õ 214 D6 Ö Extended ASCII Characters Continued DEC HEX CP 1252 ASCII Alternate Extended PS2 Scan Code ...

Страница 195: ... á ß 226 E2 â Γ 227 E3 ã π 228 E4 ä Σ 229 E5 å σ 230 E6 æ µ 231 E7 ç τ 232 E8 è Φ 233 E9 é Θ 234 EA ê Ω 235 EB ë δ 236 EC ì 237 ED í φ 238 EE î ε 239 EF ï 240 F0 ð 241 F1 ñ 242 F2 ò 243 F3 ó 244 F4 ô 245 F5 õ 246 F6 ö 247 F7 248 F8 ø 249 F9 ù Extended ASCII Characters Continued DEC HEX CP 1252 ASCII Alternate Extended PS2 Scan Code ...

Страница 196: ...Page Selection Method Country Standard Keyboard Country Honeywell Code Page Option United States standard ASCII ISO IEC 646 IRV n a 1 Automatic National Character Replacement ISO IEC 2022 n a 2 default Binary Code page n a n a 3 Default Automatic National Character replacement will select the below Honeywell Code Page options for Code128 Code 39 and Code 93 United States ISO IEC 646 06 0 1 Canada ...

Страница 197: ... 5E 60 7B 7C 7D 7E US 0 1 CA 54 95 à â ç ê î ô é ù è û CA 18 96 à â ç ê É ô é ù è û JP 28 98 CN 92 99 GB 7 87 FR 3 83 à ç µ é ù è DE 4 84 Ä Ö Ü ä ö ü ß CH 6 86 ù à é ç ê î ô ä ö ü û SE FI 2 82 É Ä Ö Å Ü é ä ö å ü DK 8 88 Æ Ø Å æ ø å NO 9 94 Æ Ø Å æ ø å IE 73 97 Ó É Í Ú Á ó é í ú á IT 5 85 ç é ù à ò è ì PT 13 92 Ã Ç Õ ã ç õ ES 10 90 Ñ ñ ç ES 51 91 Ñ Ç ñ ç COUNTRY Country Keyboard Honeywell CodePage...

Страница 198: ...32 33 34 35 36 37 53 4F 54 59 3A 3B 3C 3E 3F 38 40 3D 5A 5F 64 5B 60 65 5C 61 66 5D 62 67 63 68 69 6A 6C 104 Key U S Style Keyboard 6E 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 4B 50 55 4C 51 56 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1E 2C 1F 20 21 22 23 24 25 26 27 28 29 2B 39 2E 2F 30 31 32 33 34 35 36 37 53 4F 54 59 3A 3B 3C 3E 3F 38 40 3D 5A 5F 64 5...

Страница 199: ...3 Sample Symbols UPC A 0 123456 7890 Interleaved 2 of 5 Code 128 EAN 13 Code 39 Codabar 1234567890 Code 128 9 780330 290951 BC321 A13579B Code 93 123456 9 Straight 2 of 5 Industrial 123456 6543210 RSS 14 01 00123456789012 Matrix 2 of 5 ...

Страница 200: ...184 N3680 Decoded Engine User Guide Sample Symbols MaxiCode Micro PDF417 Test Message Test Message PDF417 Post Car Registration Zip Co Data Matrix QR Code Test Symbol Numbers ...

Страница 201: ...N3680 Decoded Engine User Guide 185 Programming Chart 0 1 2 3 4 5 6 7 8 9 ...

Страница 202: ...Programming Chart Note If you make an error while scanning the letters or digits before scanning Save scan Discard scan the correct letters or digits and Save again A B C D E F Save Discard Reset ...

Страница 203: ... Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com N36XX UG Rev C 2 17 ...

Отзывы: