Honeywell C7195A Скачать руководство пользователя страница 1

PRODUCT HANDBOOK

C7195A

WATER FLOW SENSOR

EN2R--9029 0101R2--NE

APPLICATION

The sensor is primarily designed to measure the

D

omestic

H

ot

W

ater (DHW) flow rate in domestic appliances as follows:

Combi boiler

Instanteneous Water Heater (IHW)

Other systems such as applications where the

instanteneous DHW is produced from district heat

input.

Contents

General

Page

Description

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Typical applications

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Technical

Specifications

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Electrical specifications

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Performance

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

General considerations

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Dimensional drawing

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Various

Standards and approvals

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Ordering information

10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Associated products

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Subj

ect

to

change

wi

thout

not

ic

e.

Pr

in

te

d

in

the

Net

her

lands.

Содержание C7195A

Страница 1: ...eater IHW Other systems such as applications where the instanteneous DHW is produced from district heat input Contents General Page Description 2 Typical applications 3 Technical Specifications 4 Electrical specifications 5 Performance 6 General considerations 7 Dimensional drawing 8 Various Standards and approvals 9 Ordering information 10 Associated products 11 Subject to change without notice P...

Страница 2: ...er which can then modulate the burner load for feed forward loop or simply open heat demand when the flow reaches its defined minimum rate electronic flow switch The sensor body is constructed from pressure and temperature resistant plastic with easy connections to traditional pipes used in domestic appliances Feed forward control loop concept See fig 1 Electronic Controller Flow rate input for mo...

Страница 3: ...pliances the sensor can be used in two specific ways 1 Feed forward control loop This is an advanced electronic control concept which improves the DHW temperature control thanks to fast reaction to flow rate changes Indeed before the temperature sensor sees a change in hot side the electronic board can react promptly following the flow measurement A temperature sensor can be used anyway as an opti...

Страница 4: ...t axis 5_ 5_ 5_ 5_ Fig 5 Mounting positions Fig 6 Not recommended mounting position Measuring range 2 1 30 liter min Nominal output frequency f Q x 7 0 Q flow rate in l min f pulse signal in Hz with 60 mm straight pipe on both sides Accuracy 10 of measurement over the measuring range Withstand pressure When a water pressure of 17 5 bar is applied no external leakage shall be measured and no body d...

Страница 5: ...mm with 550 mm insulation tube C7195A 1029 160 mm C7195A 1037 250 mm Electrical code Red Vcc White Vout Black ground Duty cycle of electrical output signal 30 70 Housing 5239 042 Terminal 5167T 4 Vcc red 3 Vout white 2 Blank 1 Ground black AWG24 UL1430 Fig 7 Electrical connection C7195A 1003 1011 Housing JST EPL 03V Terminal JST SLF 01Y Pt 3E 1 Ground black 2 Vout white 3 Vcc red AWG24 UL1430 Fig ...

Страница 6: ...000 hour continious operation at 10 l minute at 20 _C 7 000 hour continious operation at 10 l minute at 45 _C or 100 000 cycles operation ON 5 s OFF 5 s at 10 l minute at 45 _C After life test accuracy must be within 5 of measured value at first stage ...

Страница 7: ...cs may change In order to avoid the invasion of small particles like sand iron and rust into the water flow sensor it is advisable to install a mesh filter The waterflow to the inlet of the flow sensor should be undisturbed to meet the accuracy specifications If a device causes significant flow disturbance at the inlet of the device contact your Honeywell representative ...

Страница 8: ...NAL DRAWING Made in Japan 7 5 11 8 9635 MODEL C7195A 1003 Max Press 1 72 MPa Max Temp 80 _C PPS 40 30 30 5 30 5 11 11 PF 1 2 PF 1 2 15 2 5 12 5 11 7 5 7 5 61 WATER FLOW SENSOR Cable connection A 1029 Fig 11 Dimensional drawing C7195 ...

Страница 9: ...roved according the United Kingdom Byelaws and Regulations Certificate N0 9711081 and can therefore be used in potable water applications Other countries in general accept this certification For more details please contact Standards and Appprovals department Honeywell Combustion Control Center NL05 ...

Страница 10: ...N2R 9029 0101R2 NE 10 ORDERING INFORMATION C Water flow sensor 7 1 9 A 9999 Specification number Ordering Specification number 5 Mechanical type turbine Fig 12 Model number chart C7195A water flow sensor ...

Страница 11: ...iler application W7073C series for Combi boiler application Temperature sensors T7335 series NTC thermistor probes many options available Home and Building Control Combustion Controls Center Europe Honeywell BV Phileas Foggstraat 7 7821 AJ Emmen The Netherlands Tel 31 591 695911 Fax 31 591 695200 http europe hbc honeywell com ...