OM AIR QUALITY SENSOR

SPECIFICATION DATA & INSTALLATION INSTRUCTIONS

GENERAL

The C7110A Room Air Quality Sensor is suitable for

measuring air quality in rooms, offices, and production bays.

This mixed gas sensor can be used to control ventilation
plants. It detects unpleasant odors, tobacco smoke, and

vapors emitted by such materials as furniture, carpets, paint,

glue, etc. As proven in practice, this device detects those
substances typically present in air having a poor quality,

some of which may otherwise go undetected by room

occupants, themselves. This sensor has proven itself in
numerous applications over many years.

Models

Order Number

Description

Output

C7110A1005

Room Air Quality Sensor

0...10Vdc

FEATURES

 

Measurement of a variety of air quality factors

 

Output signal: 0...10 Vdc

 

Adjustable output offset

 

Easy installation and wiring connection

SPECIFICATION

Supply voltage

15...24 Vdc / 24 Vac

Power consumption

< 1 W

Output signal

0...10 Vdc (increases as air

 quality 

worsens)

Weight /Dimensions

approx. 125 g / see page 3

Electrical connection

Screw terminal block for

 

conductors up to 1.5 mm²

Air Quality Sensor

Sensitivity/Linearity

see Fig. 1 on page 2

Dynamic behavior

see Fig. 6 on page 4

Ambient Limits

Transport and

10...

+

70 

°

C (+14...+158 

°

F

)

storage temperature

Humidity

5...95%rh, non-condensing

Safety

Protection class

II as per EN60730-1

Protection standard

IP30 as per EN60529

Flame retardant

V0 as per UL94

Plastic ABS

FUNCTION

The electrical conductivity of a heated tin-dioxide semi-
conductor sensor varies in proportion to the number of mole-

cules of the reducing agents. This leads to a voltage at the

measuring element which is amplified to an output voltage of
0V to 10Vdc.

The following particles and gases can be detected: cigarette
smoke, hydrogen, carbon monoxide, ethanol, ammonia, etc.

In contrast to CO

sensors, which selectively measure the

concentration of only one type of gas, a mixed gas sensor is a

broadband detector, i.e. the sensor signal does not indicate
the type of gas or its concentration in ppm (parts per million).

The complex and constantly changing composition of room

air makes it necessary to perform broadband air quality
measurement.

Содержание C7110A

Страница 1: ...ity worsens Weight Dimensions approx 125 g see page 3 Electrical connection Screw terminal block for conductors up to 1 5 mm Air Quality Sensor Sensitivity Linearity see Fig 1 on page 2 Dynamic behavior see Fig 6 on page 4 Ambient Limits Transport and 10 70 C 14 158 F storage temperature Humidity 5 95 rh non condensing Safety Protection class II as per EN60730 1 Protection standard IP30 as per EN6...

Страница 2: ...TY SENSOR EN0B 0295GE51 R1200 2 Fig 1 Sensor sensitivity with different gases 2 11 16 68 1 1 Mounting holes 1 1 3 16 30 3 7 8 97 3 15 16 99 3 7 16 86 2 3 8 60 4 100 4 1 8 104 Fig 2 Dimensions and mounting holes in inches mm ...

Страница 3: ...tribution panels Run wall module wiring separately from 50 Vac or greater power wiring 1 2 LIFT PRESS Fig 3 Cover disassembly Fig 4 Wiring Connection and Trimming Potentiometer Mounting Procedure 1 The cover of the air quality sensor is fixed by a tab on the underside of the unit to disassemble the cover and the subbase see Fig 3 2 a Mount the sensor onto the wall outlet box or b bore wall holes a...

Страница 4: ...6 shows the dynamic characteristics of the air quality sensor monitored during test measurements in a sample room This voltage diagram as a function of different occupancy conditions is only an example and must be proven for other ambient conditions room unoccupied air quality sensor idling room occupied by 2 persons room occupied by 3 persons room occupied by 3 persons all 3 persons have vacated ...

Отзывы: