This guide explains how to install the AVS PC board assembly in a VISTA series residential control cabinet when using the AVS 
addressable mode. Please refer to the control’s Installation and Setup Guide and the instructions provided with this module for 
detailed information, or if using a control not compatible with the AVS addressable mode.  

 

Compatibility Note: 

When using addressable mode, the AVS is intended to work with controls having the following firmware versions: 

VISTA-20P series = version 7.0 or higher; VISTA-21iP series = version 3.0 or higher; VISTA-15P series = version 6.0 or higher.  

 

 

1.  MOUNT THE ASSEMBLY 

 

Refer to the diagram at right. 

 

a.  Position the mounting plate/PC board assembly in the bottom of the control’s 

cabinet. 

 

b.  Slide the mounting plate to the right so that the plate’s left-hand tang slides under 

the cabinet’s tie-wrap loop. 

 

c.  Secure the assembly to the cabinet using the two self-tapping screws provided. 

 

d.  Mount the control’s PC board if not already mounted; follow the control’s instructions 

for mounting the board (and optional RF Receiver board, if used). 

 

BATTERY NOTE: 

When using a 7AH battery, mount the battery vertically on the 

bottom left-hand side of the cabinet, with the terminals facing down and right 
(negative terminal closest to the PC board bracket).  

 

2.  MAKE THE AVS WIRING CONNECTIONS 

 

Refer to the diagram below. 

 

 

AVS to Panel Wiring

 

 

AVS-003-V0

SYSTEM

BATTERY

2

3

5

1

ON

4

2

3

1

ON

4

TANG

BENEATH

MOUNTING

PLATE

SECURE
WITH TWO (2)
SELF-TAP SCREWS
(SUPPLIED)

SLIDE ASSEMBLY TO RIGHT UNTIL

TANG SLIPS UNDER CABINET LOOP

CABINET
TIE-WRAP
LOOP

 

 

a. 

ECP Connection:

  

 

IMPORTANT:

 The AVS should be the 

only device connected to the control’s 
ECP terminals. Connect all other 
control panel ECP devices to the AVS 
ECP terminals. Make sure the current 
drain of connected ECP devices does 
not exceed the control’s maximum.

 

 

 

Using the red, black, green and yellow 
wires of the supplied harness, 
connect the ECP terminals from the 
control (ground, aux, data in, data out) 
to the 

Panel 

terminals on the AVS 

base unit. 

 

b. 

Phone Connection:

  

 

(use a Direct Connect cord) 

 

  Connect red and green wires to the 

control’s Incoming phone terminals.  

 

  Connect brown and gray wires to 

the base unit’s 

Handset

 terminals. 

 

  Connect the control’s Handset 

terminals to the base unit’s 

Incoming 

Phone Line

 terminals. 

AVS to Station Wiring 

a.  Mount the Station according to its 

instructions. 

 
b.  Connect the base unit’s 

AAV

 terminals 

to the station’s 

AAV

 terminals, routing 

the wires through a cabinet knockout 
and through the opening in the 
station’s case or side cutout. 

 
c.  If connecting an adjacent keypad to 

the station, connect the station’s 

Keypad

 header to the keypad’s 

connection terminals. 

 

AVS to GSMV4G/GSMX4G Module 
Connection 

a.  If using a GSMV4G or GSMX4G 

module for 2-way voice operation, 
install the module according to its 
instructions. 

NOTE:

 The module must 

be mounted within 3 feet of the 
control. 

 
b.  Connect the audio cable (not 

supplied) from the GSMV4G or 
GSMX4G module to the Audio 
connector on the AVS board.  

 
c.  Complete all other GSMV4G/ 

GSMX4G wiring following the 
instructions included with that module.

 

 

VISTA SERIES RESIDENTIAL CONTROL

BATTERY

HANDSET

(EAR

TH GND

(RING)

(TIP)

GR

Y

BRN

GRN

RED

INCOMING

PHONE LINE

(RING)

(TIP)

DIRECT
CONNECT
CORD

ECP TERMINALS

AVS-001-V2

AVS BASE UNIT

KEYPAD

BLK

GRN

YEL

RED

MIC

SPEAKERS

DATA

AUDIO

GND

+VDC

YEL

GRN

BLK

RED

AAV

AVST STATION

BRN

GRY

RING

TIP

RING

TIP

(200 FT

. MAX)

HANDSET

INCOMING

PHONE LINE

SUPPLIED HARNESS

GSMV-AUDIO CABLE (NOT SUPPLIED)

DATA

IN

DATA

OUT

PREMISES

PHONES

INCOMING

TELCO

RING

TIP

RING

TIP

KEYPAD

7

8

1

2

3

4

5

6

TRIGGER HEADER

RJ31X

1

2

3

4

5

6

7

8

RED  BLK  GRN  YEL

RED  BLK  GRN  YEL

RED  BLK  GRN  YEL

PANEL

ECP

PHONE

AAV

TO ALL
OTHER ECP
DEVICES

LED

VOLUME / ID

BUTTON

LED

NORMAL MODE

PROGRAM MODE

CALLBACK MODE

PANEL TRIGGER

MODE

GND AUX

AUDIO CONNECTOR

IMPORTANT:

DO NOT CONNECT ANY OTHER
ECP DEVICES TO PANEL.
USE AVS BASE UNIT ECP
TERMINALS FOR OTHER ECP DEVICES.

NOT
USED

DIP SW

DEVICE ADDRESS
(ADDRESS 8
SHOWN)

GSMV4G/

GSMX4G

(OPTIONAL)

VISTA-20P/

VISTA-21iP = 11

BASE UNIT

DEVICE ADDRESS

VISTA-15P = 8

2

3

4

1

ON

2

3

5

4

1

ON

2

3

5

4

1

ON

2

3

5

4

1

ON

TB 1

6
7
8

5

11

10

9

2
3
4

1

NOTE:

The AVST Remote Station must be
mounted a minimum of 12 feet (3.7m)
from the AVS Base Station and the
GSMV4G module's antenna. Using the
AVST at less than the minimum spacing
may cause undesired noise at the AVST
Remote Station.

 

 

REMOTE STATION NOTE:

 If using more than one remote station, an external power supply 

must be used. Refer to the diagram in the Installation and Setup Guide for connection diagram.

 

Base Unit LED Functions 

Steady On 

base unit is powered; normal mode 

Off 

phone ringing for callback 

Rapid Flash 

Program mode: waiting for callback code entry 

Slow Flash 

2-Way Voice mode 

Double Flash 

Listen mode or Talk mode 

 

 
 

 (