AURORA / AURORA-T

 Passive Infrared Motion Detectors 

INSTALLATION INSTRUCTIONS 

 

GENERAL INFORMATION

 

These  passive  infrared  motion  detectors  are  versatile  wall-mounted 
units  employing  Fresnel  lenses  and  offering  efficient  protection 
patterns  for  commercial  and  residential  applications.  Best  coverage 
will be obtained if mounting is selected such that the likely direction of 
intruder motion is across the pattern. 

 

When installed per the guidelines, the Split-Zone Optics technology in 
the  Aurora  Series  provides  reasonable  false  alarm  protection  against 
pets and other animals up to 40 lbs. 

 

SPECIFICATIONS

 

Detection Method:

   

Passive Infrared 

Coverage:

 

Pet Immune Lens, 

   

35 ft x 45 ft (10.6m x 13.7m), 90° 

Detection Zones: 

Pet Immune Lens - 28 zones 

   

(8 over 8 long range, 8 intermed, 4 short range) 

Pulse Processing: 

Intermediate, Standard, Harsh 

   

(use “Standard” for pet immune applications) 

Temperature Comp.: 

  Advanced dual-slope temperature 

compensation adjusts for ambients both 
above and below body temperature 

Detectable Walk Rate:

 0.5 - 10 ft/Sec (0.15 - 3m/Sec) 

Mount  Height: 

7.0 ft recommended (2.1m) 

Indicator: 

Red LED with enable/disable link 

Alarm Relay:

 

Form A, SPST, 90mA@16VDC, 

   

15-ohm protective resistor 

Input Voltage:

 

8 - 16VDC (Aurora and Aurora-T) 

   

(voltage reversal makes PIR inoperative) 

 

Current: 

Model 

w/LED alarm  w/o LED 

standby

 

 

Aurora 

10mA 

4mA 

4mA 

 

Aurora-T  10mA 

4mA 

4mA 

 

All currents nominal at 12VDC. 

Standby:

 

Power source should be capable of at least 4 
hours of battery standby 

Tamper:

 

Normally closed (with cover on), rated at 0.5A, 
30VDC (Aurora-T only) 

Operating Temp.: 

14°F - 122°F  (-10°C to +50°C)

 

Operating Humidity:

  Up to 95% RH (max.), non-condensing 

Dimensions:

 

2.9”W x 4.1”H x 1.5”D (max protrusion) 

   

(60mm x 104mm x 38mm) 

Approvals/Listing:

 

UL639, ULC S306,  

   

EN 50131-1; Security Grade 2, Environment 

   

Class II 
For Connection to an EN 60950 Class II 
Limited Power Source 

 

(2) REMOVE
     COVER

LED

(1) INSERT
     SCREWDRIVER
     IN GROOVE
     AND TWIST

PLACE LEVEL AGAINST

THESE POINTS TO ENSURE

UNIT IS VERTICAL.

AURORA-002

 

Figure 2. Cover Removal 

 

X1

A

B

B

A

X2

TOP

LED

ENABLE/DISABLE

JUMPER LINK

PULSE
PROCESSING
SELECTION
JUMPER LINK

AURORA-004

 

Figure 3. Detector Base 

 

0

22.5'

22.5'

10'

20'

30'

35'

0

7'

0

10'

20'

30'

35'

SIDE VIEW

TOP VIEW

 

ALTERNATE COUNT POLARITY

EACH ZONE CONSISTS OF 2 FIELDS

 

 
 
 

0

10

20

30

40

50

60

70

75

5

0

5

0

10

20

30

40

50

60

70

75

0

5

10

SIDE VIEW

TOP VIEW

 

 

INSTALLATION

 

For optimal pet immunity performance, be sure to follow all the guidelines 
described in “Special Instructions for Installations Containing Pets.” 

 

A.  Normal Surface Mounting

 

Mount the unit to a firm vertical surface. The wall wiring hole should be no 
more than 5/16” (8mm) in diameter. 
1.  Remove the front cover as shown in Figure 2. 
2.  Refer to Figure 3. Knockout holes “A” in the base are for normal surface 

mounting  on  a  wall  (remove  PC  board  for  full  access  to  holes).    For 
corner mounting, see 

B. Corner Mounting.

  Also break out the desired 

wire entry hole at this time, marked X1 or X2 in Figure 3. 

3.  Feed  wiring  through  the  wire  access  hole.  Make  sure  wires  have 

sufficient  slack  to  allow  the PC board to be moved up and down freely 
when the wires are connected to the board’s terminals.

 

4.  Mount  the  base.  A  level  may  be  used  on  the  front  case  to  ensure  that 

the unit is vertical (see Figure 2).  

5.  Replace  the  PC  board,  positioning  it  to  the  appropriate  setting  (see 

Vertical  Lens  Adjustment

  table  later  in  this  document). 

Note  the 

mounting orientation of this detector: terminal strip at the bottom!

 

 

6.  Refer to the 

WIRING CONNECTIONS

 section before replacing the front 

cover. 

 

B.  Corner Mounting

 

1.  Remove the front cover as shown in Figure 2. 
2.  Knockout holes “B” in the base are used for corner mounting on a wall.  

Mount in selected corner with 4 screws. 

3.  Replace  the  PC  board,  positioning  it  to  the  appropriate  setting  (see 

Vertical  Lens  Adjustment

  table  later  in  this  document). 

Note  the 

mounting orientation of this detector: terminal strip at the bottom! 

4.  Refer to the 

WIRING CONNECTIONS

 section before replacing the front 

cover.

 

 

 

Special Instructions for Installations Containing Pets 

To take full advantage of the pet immunity in the Aurora Series, the 
guidelines below should be followed:

 

   Mount the center of the detector 7 ft (2.1m) high. 

   Set the PIR sensitivity for Standard (STD). 

   Mount  where  animals  cannot  come  within  six  feet  of  the  detector  by 

climbing on furniture, boxes, or other objects. 

  Do not aim the detector at stairways that can be climbed by animals. 

NOTE

:  This unit will provide immunity to false alarms for an individual 

animal or a group of animals whose total weight is equal to or less than 40 
lbs when the room temperature is above 50°F (10°C). 

 