![Honeywell AS302P Скачать руководство пользователя страница 79](http://html.mh-extra.com/html/honeywell/as302p/as302p_operating-instructions-manual_151788079.webp)
Operating & Maintenance Instructions
75
__________________________________________________________________________
©
Honeywell - M450 001 1D - 23.05.2019
35.3. APPENDIX C
– Interface Commands
SMETS2 reference
Description
Meter
PPMID
via HAN
Type 1
device
DCC/HHT
via HAN
User Interface Commands
Activate Emergency Credit
Activate Emergency Credit in Prepayment
Mode
Y
Y
Add Credit
Accept Credit in Prepayment Mode
Y
Y
Allow Access to User Interface
Temp Access to Restricted Display Items
Y
Y
Disable Privacy PIN Protect
Disables Privacy Pin Protection
Y
Y
Enable Supply
Enable Supply if Supply Armed
Y
Y
Find Smart Metering Home Area Network
and Re-establish Comms Links
Re-establish the Home Area Network, Generate
an Event and send an Alert
Y
Y
Set Privacy PIN
Set the Privacy PIN
Y
Y
HAN Interface Commands
Activate Emergency Credit
Activate Emergency Credit in Prepayment
Mode
Y
Activate Firmware
Activate the Firmware
Y
Add Credit
Accept Credit in Prepayment Mode
Y
Add Device Security Credentials
Add a Device 1 or Device 2 Security
Credentials
Y
Adjust Debt
Apply Debt Adjustment
Y
Adjust Meter Balance
Adjust the Meter Balance
Y
Arm Supply
Return Meter to Unlocked State
Y
Clear Auxiliary Load Control Switch
Event Log
Clear Entries Auxiliary Load Control Switch
Event Log
Y
Clear Event Log
Clear Event Log Entries
Y
Disable Privacy PIN Protection
Disable Privacy PIN Protection
Y
Enable Supply
Enable Supply if Supply Armed
Y
Issue Device Security Credentials
Generate Public-Private Key Pair
Y
PPMID Enable Supply
PPMID enable Supply
Y
Read Configuration Data
Read Value of Constant Data Items
Y
Read Operational Data
Read Operational Data
Y
Receive Firmware
Receive Firmware
Y
Remove Device Security Credentials
Remove Security Credentials
Y
Request Control of HAN Connected Load
Auxiliary Control Switch
Control HAN Connected Auxiliary Load Control
Switch
Y
Reset Average RMS Over Voltage
Counter
Reset Over Voltage Counter
Y
Reset Average RMS Under Voltage
Counter
Reset Under Voltage Counter
Y
Reset HAN Connected Auxiliary Load
Control switch State
A Command to Revert to the Auxiliary Load
Switch Calendar
Y
Reset Load Limit Counter
Resets Load Limit Counter
Y
Reset Max Demand Active Power Import
Value
Reset Max Demand Active Power Import Value
Y
Reset Max Demand Active Power Export
Value
Reset Max Demand Active Power Export Value
Y
Reset Max Demand Active Power
(Configurable Time) Import Value
Reset Max Demand Active Power (Configurable
Time) Import Value
Y
Reset Meter Balance
Reset Meter Balance to Zero
Y
Reset Tariff Block Counter Matrix
Tariff Block Counter Matrix to Zero
Y
Restrict Data
Restrict Personnel Data
Y