AQ250 SERIES HYDRONIC CONTROL PANELS

69-1982

2

1 Check You Have All the Necessary 

Equipment For a Successful 

Installation

A)

AQ2000 Series components

• AQ250 Control Panel

• AQ Expansion Zoning Panels (if more than four 

space heating zones in the system)

• AQ1000 Thermostats (one for every space heating 

zone being controlled)

B)

Boiler supply and return temperature sensors (included 

with AQ250 Control Panels)

C)

Low voltage thermostat wire

D)

Zoning equipment (zone valves or pumps)

2 Read All Instructions Carefully 

Before Proceeding

The AQ250 Control Panels are part of a totally new family of 

hydronic controls! And although they - and other AQ2000 

system components - are VERY easy to install and operate, 

they’re different than other hydronic controls that you have 

previously installed. So take a moment to read through this 

quick installation guide BEFORE beginning the installation. 

Failure to follow them could damage the product or cause a 

hazardous condition.

3 Familiarize Yourself With The AQ250 

Control Panel

Layout

AQ250 Control Panels consist of three functional 

components:

• the AQ10X38 transformer (power supply module), which 

connects to 120 Vac power and supplies 24Vac power to 

the Control Module and Zoning Modules; and

• the AQ1500B0 boiler / DHW Control Module, which 

controls the boiler and domestic hot water (DHW) functions 

as well as coordinating the overall operation of the 

hydronic system 

• a Zoning Module capable of controlling 4 space heating 

zones

The Zoning Module is available in two versions:

• AQ1574V4 (part of the AQ2504B4 Control Panel) for 

zoning with 24 Vac zone valves with end switches 

• AQ1554P2 (part of the AQ2504B2 Control Panel) for 

zoning with either line voltage circulators or 24 Vac zone 

valves without end switches.

AQ250 Control Panels can control a maximum of 16 zones by 

connecting up to 3 additional Expansion Zoning Panels to the 

AQ250 Control Panel. Each Expansion Zoning Panel is 

configured with its own bank of DIP switches, located in the 

left most section of each Zoning Module. To expand the 

capacity of an AQ250 Control Module beyond 16 zones, an 

AQ254 Add-A Temperature 

Expansion Control Panel is 

required. The hydronic system can be expanded by 16 zones 

for each AQ254 connected to the AQ2000 network; a 

maximum of

 three (3) AQ254 Panels may be connected to an 

existing AQ2000 Control Panel  for a total system capacity of 

64 zones.

NOTE: If an AQ254 is used for controlling the temperature in 

a mixed loop, it can reset the that mixed loop temper-

ature using LOAD reset, but not OUTDOOR reset, 

as the AQ250 panel does not have input terminals 

for an outdoor sensor.

In general, the top terminals of all AQ2000 Series Control 

Panel components carry low voltage (24 Vac) power and the 

bottom terminals carry line voltage (120V) power. The only 

exception to this is the AQ1554P2 Zoning Module when used 

with low voltage zone valves (without end switches). In this 

case, the bottom terminals of the Transformer and Control 

Module carry line voltage, but the bottom terminals of the 

Zoning Module will carry low voltage power.

Fig. 1 AQ250 Control Panel Layouts (AQ2504B4 shown)

Zone 1 

Zone 2 

Zone 3 

Zone 4 

ZR 

Boiler 

DHW 

Aux 

M23734A

LOW VOLTAGE 

(24 V) 

LOW VOLTAGE 

(24 V) 

ZONING MODULE 

CONTROL MODULE 

TRANSFORMER

LINE VOLTAGE 

(120 V) 

Содержание AQ250 Series

Страница 1: ...plies to both the AQ2504B2 and AQ2504B4 Con trol Panels Where there are specific instructions or details relating to the 4B2 or 4B4 Control Pan els the full model number i e AQ2504B4 is used The term Control Panel refers to an assembled product consisting of a transformer Control Module and Zoning Module all contained within an AQ2000 panel enclosure The term AQ255 refers to all of the AQ2554P2X A...

Страница 2: ...of the AQ2504B4 Control Panel for zoning with 24 Vac zone valves with end switches AQ1554P2 part of the AQ2504B2 Control Panel for zoning with either line voltage circulators or 24 Vac zone valves without end switches AQ250 Control Panels can control a maximum of 16 zones by connecting up to 3 additional Expansion Zoning Panels to the AQ250 Control Panel Each Expansion Zoning Panel is configured w...

Страница 3: ...ll two lower screws If there are Expansion Zoning Panels to install they should be mounted on the wall now If not skip this section and proceed to Step 5 Mount Thermostats In The Zones 3 Remove wire channel plugs from the AQ250 Control Panel and any Expansion Panels see Figure 3 4 Mount Expansion Zoning Panel on the right hand end of the AQ250 Control Panel Install two top screws of the Expansion ...

Страница 4: ...of the Control Panel and moving clockwise around the panel refer to Figure 4 wire components to the AQ250 Control Panel and Expansion Zoning Panels if installed in the following six steps Step 1 Factory pre wiring of the Control Panels is shown as dotted lines in Figure 4 In addition to the pre wiring run low voltage jumper wires from available R and C terminals to the R and C terminals of any Exp...

Страница 5: ...ther on the AQUATROL network using communication bus wiring This wiring MUST connect all AQ2000 components otherwise features that depend on this networked communication e g zone synchronization will not function This communication bus wiring is polarity insensitive the installer does not need to worry about a ve or ve orientation of the wires if there are two wires connected to the B B Exp Bus IN...

Страница 6: ...e bottom wiring channel between the AQ1500 Control Module and the Zoning Module Run jumper wires from the N and L terminals on the bottom of the Control Panel s transformer through the wiring channel across the bottom of the Control Panel to the corresponding N and L terminals of the Zoning Module NOTE If low voltage zone valves are used with the AQ2504B2 Control Panel the low voltage out put stic...

Страница 7: ...le to power the valves See Figure 11 for recommended wiring of additional low voltage VA capacity to AQ2000 Series Zoning Modules Fig 11 Wiring of additional low voltage VA capacity Step 5 Line Voltage System Outputs Boiler Pump DHW Device Aux Output See Figures 12a and 12b for wiring diagrams for the line voltage outputs Follow general instructions below for wiring of these pumps to the AQ250 Con...

Страница 8: ...FUNCTION AQUASTAT 2 TO AUXILIARY DEVICE INSTALLER DEFINED FROM LINE VOLTAGE 120V TERMINALS N AND L ON BOTTOM OF TRANSFORMER JUMPERED AT FACTORY BOILER PUMP M13899 ZC ZR B1 B2 C1 C2 L1 L2 T T G L8124 L7224 R8184 BURNER AND IGNITION C554 F F T T BLACK WHITE ORANGE POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED L1 HOT L2 1 1 FOR INSTALLATIONS USING A TRIPLE FUNCTION AQUASTA...

Страница 9: ...as shown in Figure 13 The exact wiring schematic will depend on what is connected to these dry contacts Fig 13 Wiring of the AUX Pump line voltage rated dry contacts example shown is a by pass pump Step 6 Connection To Line Voltage Power Finally connect the N and L line voltage inputs of the AQ250 Control Panel at the bottom of the transformer to the electrical distribution panel and power up the ...

Страница 10: ... the pre set factory defaults for each DIP switch is shown in Table 2 Zoning Modules 2 The AQ1554P2 pump Zoning Module and AQ1574V4 valves with end switches Zoning Module both have DIP switches in 8 switch banks and are concealed behind snap on covers as shown in Figure 15 A chart of the different settings for each DIP switch is attached to the inside of the DIP switch covers More detailed explana...

Страница 11: ... each Module e g AQ1500B0 for the Control Module is printed on the top of the DIP switch settings charts The part number for each Module is printed on the Module s low voltage connec tions label directly above where the DIP switches are located d For the fourth Zoning Module connected to the AQ1500 Control Module make sure that DIP switch 4 is set to the right hand position and DIP switches 1 2 an...

Страница 12: ...ed during Auto Test DIP Switch Description Label and Factory Settings 1 Zone Address For each group of 4 zones there can be only one DIP switch in the right hand position The first Zoning Module connected to each Control Module must have the first of these DIP switches 1 4 set to the right hand position with the other 3 switches set to the left The second Zoning Module s 5 8 switch must be in the ...

Страница 13: ...tion for Zoning Modules enables the installer to test all zones wired to the Zoning Module by sequentially activating the equipment connected to each zone output pump or valve for 15 seconds Each step of the Auto Test routine may be paused or skipped by pressing the Test button ZONING MODULE DIAGNOSTIC LED The LED labeled DIAGNOSTIC located above the DIP switches on the AQ155 AQ157 Zoning Modules ...

Страница 14: ...st feature described in section 8A as follows To purge all zones on the AQUATROL network press the Test button on the AQ1500B0 Control Module once to begin the Auto Test routine Quickly press it again 3 times until the Boiler relay LED is illuminated AND the Diagnostic LED of the AQ1500B0 is blinking slowly indicating the Auto Test routine has been paused The boiler pump will now remain energized ...

Страница 15: ... AQ250 provides Control Module diagnostic information via the DIAGNOSTIC LEDs located above the DIP switches on the AQ1500B0 Control Module The AQ250 provides Zoning Module diagnostic information via the DIAGNOSTIC LEDs located above the DIP switches on its Zoning Module s This information helps the installer correctly identify system problems making troubleshooting much faster The following table...

Страница 16: ...Solutions Honeywell International Inc Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Toronto Ontario M1V 4Z9 customer honeywell com U S Registered Trademark 2007 Honeywell International Inc 69 1982 C H 11 07 ...

Отзывы: