Section 2: Mounting and Wiring
2-7
Backup Battery Connection
The included battery (K14139) is used for backup in the event of power loss to the
communications module. It does not provide power to the control panel.
The battery can provide over 24 hours of system life in the event of a power failure.
A programmable power loss message can alert the AlarmNet Control Center when system
power is lost (power loss messages are reported within 1-3 hours of actual loss).
The module transmits a low-battery message (programmable) when the battery reaches
5.7V ±5%, indicating subsequent messages may not be transmitted.
The system shuts down when the battery falls below 5.1V, and radio transmissions are no
longer possible.
If system power is restored before the module shuts down, a power restore message is sent
within 1-3 hours after power is restored, and the battery is recharged using the IGSMHS’s
built-in battery charger. If system power is restored after the IGSMHS has shut down, a
power-on reset condition exists, the module initializes itself and the battery will recharge.
Install the battery as follows, and refer to the
Summary of Connections
diagram at the end of
this document.
1.
Place the battery inside the case back.
2.
Snap the right side of the battery clip onto the inside of the case back and secure the left
side with the screw provided.
NOTE:
Do not plug the battery in until after you have powered-up the IGSMHS.
Initial Power-Up Sequence
Before connecting power, check that the following have been completed:
If using ECP, 4204 or 2-4204 Mode, terminal block TB1 V+ and GND terminals are
connected to the control panel’s auxiliary power output: 12VDC nominal.
Plug in the transformer.
Connect the red and black battery cables to the battery terminals. Connect battery cable
to connector J1.
Power up the control panel.
Initially, all IGSMHS programming options are set to the factory default settings.
Содержание AlarmNet IGSMHS
Страница 2: ......
Страница 10: ...IGSMHS Installation and Setup Guide 1 6 ...
Страница 18: ......
Страница 40: ...IGSMHS Installation and Setup Guide 3 22 ...
Страница 44: ...IGSMHS Installation and Setup Guide 4 4 ...
Страница 52: ...IGSMHS Installation and Setup Guide A 2 ...
Страница 54: ...IGSMHS Installation and Setup Guide B 2 ...
Страница 58: ...IGSMHS Installation and Setup Guide D 2 ...
Страница 59: ...NOTES ...
Страница 60: ...NOTES ...
Страница 61: ...NOTES ...
Страница 62: ...NOTES ...