ADEMCO 5821 Flood Detector with Temperature Sensing Option 
Installation Instructions

 

GENERAL INFORMATION 

The  ADEMCO  5821  Flood  Detector  &  Temperature  Sensor  is  a  wireless  transmitter  used  with  Honeywell’s  alarm 
systems that support 5800 series devices.  The 5821 can be configured to operate, 

 

 as a stand-alone temperature sensor and/or, 

 

 as either a Flood Detector 

or

 Remote Temperature Sensor.   

The 5821 in 

combination with the FP280 or ADEMCO 470PB probe can be used to sense floods

 in basements 

and  other  areas  where  there  is  a  possibility  of  flooding.    The  5821  will  send  an  alarm  when  the  preset 
temperature  limit  is  exceeded  or  when  a  flood  is  detected.    Temperature  monitoring  and  flood  detection  is 
dependent on the operating mode selected.  Refer to Table 1 for applicable operating modes.   

The 5821 

in combination with the ADEMCO T280R

 

temperature probe

 is ideal for monitoring refrigerators and 

freezers in restaurants, kitchens and warehouses where food storage is a concern.   

A separate 5821 is required for each external probe being used.   

 

Flood detection is monitored remotely using the FP280 or ADEMCO 470PB probe with the supplied resistor. 

 

Room temperature is monitored at the device using the 5821’s internal sensor.   

 

Refrigerator or Freezer temperature is monitored remotely using the ADEMCO T280R temperature probe.   

In  refrigerator  or  freezer  applications,  when  the  temperature  increases  past  the  high  threshold  limit  and  a  delay  of 
greater than 30 minutes passes, an alarm is triggered.  This preset delay offers greater reliability against false alarms, 
especially due to open refrigerator or freezer doors.   

TAMPER SUPERVISION 

The 5821 tamper supervision feature (Loop 4) causes a trouble signal to be sent to the control if the unit’s cover is 
removed from the base or if an external probe is used and the wire is cut (open) or the probe is shorted.   The tamper 
switch is also used to program the unit’s serial number and loop assignments to the control panel. 

Wireless Transmission Path Test 

Before permanently installing the detector, determine that there is good signal reception from the proposed location. 
Perform the test procedure described in TESTING THE DETECTOR section.  Once confirmed, mount the detector. 

 

MOUNTING THE DETECTOR 

 

Mount  the  5821  in  any  direction,  on  a  wall  or 
ceiling, within the protection area.   

 

We recommend that the mounting plate be used.   

 

Avoid  mounting the  detector  near  heat  generating 
devices  (e.g.  ovens,  heat vents,  furnaces,  boilers) 
or to a metal cabinet or surface.   

When used in-conjunction with:  

-

 

FP280  flood  sensor  probe, 

with  built-in  wire 

approx.  16  feet  long  (5  meters)  ready  to  tie  into 
5821 device.  

-

 

ADEMCO  470PB  flood  sensor  probe

,  use  no 

more  than  48  inches  of  wire  from  the  5821  to  the 
flood  sensor  and  connect  the  termination  resistor 
across the probes terminals.   

-

 

ADEMCO  T280R  temperature  probe

,  use  the 

shortest  wire  possible  (less  than  96  inches)  to 
improve the signal integrity.     

 
 

2

1

ON

5821-008-V0

 
 

5821-009-V0

2

1

ON

DIP SWITCH

COVER

RETAINING

HOOKS (3)

ANTENNA

Panasonic CR123A

Duracell DL123A

2

1

ON

WIRE ENTRY

HOLE

COVER 

PRY-OFF

SLOT

LOOP
TERMINALS

TAMPER
SWITCH

 

IMPORTANT:

 DO NOT remove the circuit board from the back case plastic. 

 External Probe Wiring Connections (If used) 

1.

 

With the battery not inserted, connect the wires to the unit's sensor terminals; see below. 

2.

 

Install the battery.   

Содержание ADEMCO 5821

Страница 1: ...especially due to open refrigerator or freezer doors TAMPER SUPERVISION The 5821 tamper supervision feature Loop 4 causes a trouble signal to be sent to the control if the unit s cover is removed from the base or if an external probe is used and the wire is cut open or the probe is shorted The tamper switch is also used to program the unit s serial number and loop assignments to the control panel ...

Страница 2: ...Cold Temp Sensing can be used in combination with any of the other operating modes To use the transmitter to monitor two different conditions you must program each loop used on the 5821 as its own zone and you must set the DIP Switches as shown for the combination functions in Table 1 TABLE 1 OPERATING MODE SETTINGS Sensing Probe to Term Block Loop No DIP 1 DIP 2 Flood Sensing Flood FP280 or 470PB...

Страница 3: ...one Programming mode 2 Enter the zone number to be programmed 3 Enter the applicable zone type when prompted zone types such as 24 Hr Aux Waterflow etc should be used depending on the function of the zone and the control panel being used see the control panel s instructions for available zone types and definitions 4 When prompted enter Input Type 03 3 on some controls Supervised RF Transmitter 5 W...

Страница 4: ...ystem The installer should assume the responsibility of developing and offering a regular maintenance program to the user as well as acquainting the user with the proper operation and limitations of the alarm system and its components parts Recommendations must be included for a specific program of frequent testing at least weekly to ensure the system s proper operation at all times FCC IC STATEME...

Отзывы: