ADEMCO 5800RL Wireless Relay Module – Installation Instructions

 

 

INTRODUCTION 

The  ADEMCO  5800RL  is  a  Wireless  Relay  Module  that 
enables  use  of  remote  sounders  and/or  remote  arm/disarm 
indicators using two relays activated by wireless signals from 
a  LYNX  control.  The  5800RL  can  also  send  tamper  and 
supervision  signals  to  the  LYNX  if  so  programmed.  The 
5800RL  is  compatible  with  LYNX  Plus  controls  having 
software  versions  9.0  or  higher  and  LYNX  Touch  controls. 
Refer  to  the  LYNX  control  installation  and  setup  guide  for 
software compatibility and zone programming information. 

5800RL

RELAY MODULE

TAMPER AND

SUPERVISION

SIGNALS SENT

TO CONTROL

MODULE'S TWO

RELAYS ARE

ACTIVATED BY

SYSTEM

CONDITIONS

5800RL-004-V1

BYPASS

NO DELAY

RECORD

TEST

FUNCTION

STATUS

VOLUME

PLAY

CODE

LIGHTS ON

LIGHTS OFF

CHIME

ESCAPE

ADD

DELETE

SELECT

OFF

STAY

1

3

2

AWAY

AUX

4

6

5

ARMED

READY

7

9

8

0

 

Figure 1.  Lynx Interface Diagram 

 

MOUNTING LOCATION GUIDELINES 

Use the following guidelines when selecting a mounting 
location for the 5800RL Relay Module (see Figure 2): 

 

Mount the 5800RL in a high location for best wireless 
reception. 

 

Do not mount the 5800RL on or near metal objects. This 
decreases range and/or blocks wireless transmissions. 

 

Locate the 5800RL at least 10 feet from any remote 
keypad to avoid interference from the microprocessors in 
those units. 

 

To avoid voltage loss that occurs on long power lines, 
mount the external power supply unit in close proximity to 
the 5800RL. 

Mounting, Wiring, and Setup 

 

IMPORTANT:  

Before  permanently  mounting  the  5800RL, 

perform  the  setup  procedure  described  in  the 

Setting  Up 

the 5800RL

 section. 

 

1.  Remove the 5800RL's cover from the base (using a small 

flat head screwdriver, insert screwdriver’s tip in slot at top 
of the cover and twist). 

2.  Using  the  5800RL  base  as  a  template,  position  in  the 

desired  location  and  mark  the  two  mounting  holes.  See 
Figure 2 for mounting hole locations. 

3.  Attach the 5800RL base using the fasteners supplied. 

Screws  and  plastic  anchors  are  suitable  for  a  typical 
installation,  but  you  may  use  any  two  fasteners  that 
secure the base firmly to the mounting surface. 

NOTE: 

This  product  uses  latching  relays,  which  retain  their 

open/closed position even when power is disconnected. Due 
to  shocks  or  vibration  during  shipment  and  installation,  the 
out-of-box state of these relays may be either open or closed. 
When power is first applied, the relay will be set to its correct 
initial  state.  Please  bear  this  in  mind  during  installation;  it  is 
strongly  recommended  that  you  wire  this  module  and  apply 
power to it before energizing any external circuit controlled by 
the latching relay. 

4.  Connect relay and power wiring to the 5800RL’s terminals. 

Refer to Figure 3 for a typical relay application. 

The  5800RL  can  be  powered  from  either  an  AC  transformer 
or  DC  power  supply  external  power  source  connected  to 
terminals 7 and 8 (see Figure 3). 

Power source ratings and connections are as follows: 

Type 

Rating 

Connected to… 

Source Example 

AC 

9VAC, 15VA 

terminals 7 and 8 

Ademco 1332 

DC 

12VDC, 100mA 

terminals 7 and 8 
or plugged into 
power connector. 

AD12612 

 

 

 

NOTE: 

Use  of  power  sources  with  higher  or  lower  voltages 

may  result  in  damage  or  failure  to  operate  properly.  Non-
ADEMCO  power  supplies  may  have  connectors  installed. 
Remove  these  connectors  prior  to  attempting  to  connect 
power supply to 5800RL. 

TAMPER
SWITCH

2 - NO

3 - COM

4 - NC

5 - NO

6 - COM

7 - AC OR DC (+) IN

1 - NC

8 - AC OR DC (  ) IN 

RELAY A

RELAY B

LED

(RED)

LED

(YELLOW)

LED

(GREEN)

RF INTERFERENCE

LED (RED)

ANTENNA 2

ANTENNA 1

DIP

SWITCH

MOUNTING

HOLE

MOUNTING

HOLE

1 2 3 4 5 6

ON

OFF

 

Figure 2.  5800RL Diagram 

 

2 - NO

3 - COM

4 - NC

5 - NO

6 - COM

7 - AC OR DC (+) IN

1 - NC

8 - AC OR DC (  ) IN 

RELAY A

RELAY B

5800RL-005-V0

ANTENNA 2

SOUNDER

ANTENNA 1

1 2 3 4 5 6

ON

OFF

ADEMCO AD12612

AUX PWR SUPPLY

(12 VDC)

AC

IN

+

_

DC

OUT

1361

+

_

RED

BLA

CK

POWER SUPPLY

BACKUP

BATTERY 12VDC

+

PWR SUPPLY

XFMR

16.5VAC

 

Figure 3.  Typical Sounder Wiring Installation 

Setting Up the 5800RL 

Refer  to  RELAY  and  LED  Operation section  and  DIP  Switch 
(Figure 4) in order to set up the 5800RL as follows:

 

5.  Set DIP switches 3-6 (Figure 4) to the appropriate House 

ID (1-31). Make sure the House ID set by the DIP 
switches matches that entered in the LYNX control. 

6.  If module supervision and/or tamper protection is desired, 

program the 5800RL’s tamper/supervisory loop (1) as a 
zone and enroll its serial number. 

Note the following when enrolling: 

Zone Type = 5 (trouble by day/alarm by night) 
Input Type = 3 (RF) 
Loop Number = 1 

7.  Position the wiring in the exit slot and reinstall the 

5800RL’s cover on the base. 

Test the 5800RL module with the rest of the system. 
 