ADEMCO 5800RL Wireless Relay Module – Installation Instructions
INTRODUCTION
The ADEMCO 5800RL is a Wireless Relay Module that
enables use of remote sounders and/or remote arm/disarm
indicators using two relays activated by wireless signals from
a LYNX control. The 5800RL can also send tamper and
supervision signals to the LYNX if so programmed. The
5800RL is compatible with LYNX Plus controls having
software versions 9.0 or higher and LYNX Touch controls.
Refer to the LYNX control installation and setup guide for
software compatibility and zone programming information.
5800RL
RELAY MODULE
TAMPER AND
SUPERVISION
SIGNALS SENT
TO CONTROL
MODULE'S TWO
RELAYS ARE
ACTIVATED BY
SYSTEM
CONDITIONS
5800RL-004-V1
BYPASS
NO DELAY
RECORD
TEST
FUNCTION
STATUS
VOLUME
PLAY
CODE
LIGHTS ON
LIGHTS OFF
CHIME
ESCAPE
ADD
DELETE
SELECT
OFF
STAY
1
3
2
AWAY
AUX
4
6
5
ARMED
READY
7
9
8
0
Figure 1. Lynx Interface Diagram
MOUNTING LOCATION GUIDELINES
Use the following guidelines when selecting a mounting
location for the 5800RL Relay Module (see Figure 2):
•
Mount the 5800RL in a high location for best wireless
reception.
•
Do not mount the 5800RL on or near metal objects. This
decreases range and/or blocks wireless transmissions.
•
Locate the 5800RL at least 10 feet from any remote
keypad to avoid interference from the microprocessors in
those units.
•
To avoid voltage loss that occurs on long power lines,
mount the external power supply unit in close proximity to
the 5800RL.
Mounting, Wiring, and Setup
IMPORTANT:
Before permanently mounting the 5800RL,
perform the setup procedure described in the
Setting Up
the 5800RL
section.
1. Remove the 5800RL's cover from the base (using a small
flat head screwdriver, insert screwdriver’s tip in slot at top
of the cover and twist).
2. Using the 5800RL base as a template, position in the
desired location and mark the two mounting holes. See
Figure 2 for mounting hole locations.
3. Attach the 5800RL base using the fasteners supplied.
Screws and plastic anchors are suitable for a typical
installation, but you may use any two fasteners that
secure the base firmly to the mounting surface.
NOTE:
This product uses latching relays, which retain their
open/closed position even when power is disconnected. Due
to shocks or vibration during shipment and installation, the
out-of-box state of these relays may be either open or closed.
When power is first applied, the relay will be set to its correct
initial state. Please bear this in mind during installation; it is
strongly recommended that you wire this module and apply
power to it before energizing any external circuit controlled by
the latching relay.
4. Connect relay and power wiring to the 5800RL’s terminals.
Refer to Figure 3 for a typical relay application.
The 5800RL can be powered from either an AC transformer
or DC power supply external power source connected to
terminals 7 and 8 (see Figure 3).
Power source ratings and connections are as follows:
Type
Rating
Connected to…
Source Example
AC
9VAC, 15VA
terminals 7 and 8
Ademco 1332
DC
12VDC, 100mA
terminals 7 and 8
or plugged into
power connector.
AD12612
NOTE:
Use of power sources with higher or lower voltages
may result in damage or failure to operate properly. Non-
ADEMCO power supplies may have connectors installed.
Remove these connectors prior to attempting to connect
power supply to 5800RL.
TAMPER
SWITCH
2 - NO
3 - COM
4 - NC
5 - NO
6 - COM
7 - AC OR DC (+) IN
1 - NC
8 - AC OR DC ( ) IN
RELAY A
RELAY B
LED
(RED)
LED
(YELLOW)
LED
(GREEN)
RF INTERFERENCE
LED (RED)
ANTENNA 2
ANTENNA 1
DIP
SWITCH
MOUNTING
HOLE
MOUNTING
HOLE
1 2 3 4 5 6
ON
OFF
Figure 2. 5800RL Diagram
2 - NO
3 - COM
4 - NC
5 - NO
6 - COM
7 - AC OR DC (+) IN
1 - NC
8 - AC OR DC ( ) IN
RELAY A
RELAY B
5800RL-005-V0
ANTENNA 2
SOUNDER
ANTENNA 1
1 2 3 4 5 6
ON
OFF
ADEMCO AD12612
AUX PWR SUPPLY
(12 VDC)
AC
IN
+
_
DC
OUT
1361
+
_
RED
BLA
CK
POWER SUPPLY
BACKUP
BATTERY 12VDC
+
PWR SUPPLY
XFMR
16.5VAC
Figure 3. Typical Sounder Wiring Installation
Setting Up the 5800RL
Refer to RELAY and LED Operation section and DIP Switch
(Figure 4) in order to set up the 5800RL as follows:
5. Set DIP switches 3-6 (Figure 4) to the appropriate House
ID (1-31). Make sure the House ID set by the DIP
switches matches that entered in the LYNX control.
6. If module supervision and/or tamper protection is desired,
program the 5800RL’s tamper/supervisory loop (1) as a
zone and enroll its serial number.
Note the following when enrolling:
Zone Type = 5 (trouble by day/alarm by night)
Input Type = 3 (RF)
Loop Number = 1
7. Position the wiring in the exit slot and reinstall the
5800RL’s cover on the base.
Test the 5800RL module with the rest of the system.