PRODUCT DESCRIPTION
Activ8
Activ8
Activ8
Activ8 BG
BG
BG
BG
PROFESSIONAL
PASSIVE INFRARED
SHOCK & BREAKAGE
DETECTORS
With PET IMMUNITY
INSTALLATION INSTRUCTIONS
P/N 7101493 REV. A A.Y.
A new generation of professional movement
spread spectrum analyzing PIR, Shock & Glass
Breakage detectors.
The detector provides an analysis of
environmental conditions through the entire
movement spread frequency spectrum.
It listens for sounds of breaking glass, which
produces two sequential signals of different
frequencies “SHOCK” and “GLASS”. The unique
phased frequency detection circuitry of this
detector allows detection of both shock signal and
the strong signal of glass breakage creating a
false alarm free detector.
The detector does not need to be attached to the
window, providing volume protection, and
allowing you to protect several windows with one
detector.
MOUNTING THE DETECTOR
Activ8 BG FEATURES
DETECTION PATTERN
TYPICAL INSTALLATION
FEATURES
•
Quad (Four element) pyrosensor.
•
Two independent relay outputs for
GLASS/SHOCK and PIR alarm
signals.
•
VLSI SMD technology.
•
PIR sensitivity adjustment.
•
GLASS sensitivity adjustment.
•
SHOCK sensitivity adjustment.
•
Volume
protection.
•
Automatic
temperature
compensation.
•
Height installation calibrations
free.
•
Environmental
immunity.
•
The Activ8 BG provides
pet immunity
up to 25Kg. Pet active bellow 1m.
SELECT MOUNTING LOCATION
Choose a location in front of the protected
windows, in direct line of sight within 4.5m. In
case of more then one window, place the detector
in the center area facing the windows, make sure
that this location will be most likely to intercept an
intruder, that may across the PIR beams.
See PIR detection beams.
See SHOCK and GLASS detection area.
If heavy blinds or curtains cover the glass, you
must locate the detector behind the blinds on
the window frame or above it, otherwise the
blinds might block the sound.
AVOID THE FOLLOWING LOCATIONS
∗
Facing direct sunlight.
∗
Facing areas subject with temperature
changes.
∗
Areas with air ducts or substantial air flows.
∗
Facing metal doors.
∗
Close to door entrance bells measuring 2” (or
larger) in diameter.
REMOVAL OF FRONT COVER
MOUNTING DETECTOR BASE
1. To remove the front cover, unscrew the holding
screw and gently raise the front cover.
2. To remove the PC board, carefully unscrew the
holding screw located on the PC board.
3. Break out the desired holes for proper installing.
4. The circular and rectangular indentations at the
bottom base are the knockout holes for wire
entry. You may also use mounting holes that are
not in use for running the wiring into the
detector.(For option with bracket - lead wire
through the bracket)
5. Mount the detector base to the wall, corner or
ceiling. (For option with bracket install bracket).
6. Reinstall the PC board by fully tightening the
holding screw. Connect wire to terminal block.
7. Replace the cover by inserting it back in the
appropriate closing pins and screw in the holding
screw.
KNOCKOUT HOLES
DETECTOR INSTALLATION
CIRCUIT LAYOUT
TERMINAL BLOCK CONNECTIONS
Terminals 1 & 2 - Marked “ TAMPER ”
If a Tamper function is required connect these
terminals to a 24-hour normally closed protective
zone in the control unit. If the front cover of the
detector is opened, an immediate alarm signal will
be sent to the control unit.
Terminals 3 & 4 - Marked
“
R-PIR
”
These are the output PIR relay contacts of the
detector. Connect to a normally closed zone in the
control panel.
Terminal 5 - Marked “ EOL ” –
End of line option.
Terminals 6 & 7 - Marked
“
R-MIC
”
These are the output MICROPHONE relay
contacts of the detector. Connect to a normally
closed zone in the control panel.
Terminal 8 - Marked “ + ” (+12V)
Connect to a positive Voltage output of 8.2 -16Vdc
source (usually from the alar control unit)
Terminal 9 - Marked “ - ” (gnd)
Connect to the negative Voltage output or ground
of the control panel.
A. Wire
access
holes
B. Use for flat wall
mounting
C. Corner mounting -
use all 4 holes.
Sharp left or right
angle mounting -
use 2 holes (top
and bottom)
D. For
bracket
mounting
D
B
B
B
B
C
C
C
C
Unscrew the holding
screw and open base
A
A
A
15m
The Activ8 BG provides immunity up to 25Kg.
For better immunity avoid installation in areas
where pets can reach upwards.