PRODUCT DESCRIPTION

    

Activ8 

Activ8 

Activ8 

Activ8 BG

BG

BG

BG    

    

PROFESSIONAL

 

PASSIVE INFRARED 

SHOCK & BREAKAGE 

DETECTORS 

With PET IMMUNITY 

 

  

INSTALLATION INSTRUCTIONS  

 

 

P/N  7101493   REV. A  A.Y.

 

 

A new generation of professional movement 
spread spectrum analyzing PIR, Shock & Glass 
Breakage detectors. 

The detector provides an analysis of 
environmental conditions through the entire 
movement spread frequency spectrum. 
It listens for sounds of breaking glass, which 
produces two sequential signals of different 
frequencies “SHOCK” and “GLASS”. The unique 
phased frequency detection circuitry of this 
detector allows detection of both shock signal and 
the strong signal of glass breakage creating a 
false alarm free detector. 
The detector does not need to be attached to the 
window, providing volume protection, and 
allowing you to protect several windows with one 
detector. 
 

 

MOUNTING THE DETECTOR 

 

 

    

 

 
 

 

Activ8 BG FEATURES 

DETECTION PATTERN

    

TYPICAL INSTALLATION 

FEATURES 

 

Quad (Four element) pyrosensor. 

 

Two independent relay outputs for 

GLASS/SHOCK and PIR alarm 
signals. 

 

VLSI SMD technology. 

 

PIR sensitivity adjustment. 

 

GLASS sensitivity adjustment. 

 

SHOCK sensitivity adjustment. 

 Volume 

protection. 

 Automatic 

temperature 

compensation. 

 

Height installation calibrations 

free. 

 Environmental 

immunity. 

 

The Activ8 BG provides 

pet immunity

 

up to 25Kg. Pet active bellow 1m. 

 

 

 

 

SELECT MOUNTING LOCATION 

Choose a location in front of the protected 
windows, in direct line of sight within 4.5m. In 
case of more then one window, place the detector 
in the center area facing the windows, make sure 
that this location will be most likely to intercept an 
intruder, that may across the PIR beams. 

See PIR detection beams. 
See SHOCK and GLASS detection area. 
If heavy blinds or curtains cover the glass, you 
must locate the detector behind the blinds on 
the window frame or above it, otherwise the 
blinds might block the sound.  

AVOID THE FOLLOWING LOCATIONS 

  Facing direct sunlight. 

  Facing areas subject with temperature 

changes. 

  Areas with air ducts or substantial air flows. 

  Facing metal doors. 

  Close to door entrance bells measuring 2” (or 

larger) in diameter. 

REMOVAL OF FRONT COVER

 

MOUNTING DETECTOR BASE

    

 

 
 

1. To remove the front cover, unscrew the holding 

screw and gently raise the front cover. 

2.  To remove the PC board, carefully unscrew the 

holding screw located on the PC board. 

3.  Break out the desired holes for proper installing. 

4. The circular and rectangular indentations at the 

bottom base are the knockout holes for wire 
entry. You may also use mounting holes that are 
not in use for running the wiring into the 
detector.(For option with bracket - lead wire 
through the bracket) 

5. Mount the detector base to the wall, corner or 

ceiling. (For option with bracket install bracket). 

6. Reinstall the PC board by fully tightening the 

holding screw. Connect wire to terminal block. 

7. Replace the cover by inserting it back in the 

appropriate closing pins and screw in the holding 
screw. 

    

KNOCKOUT HOLES 

 

DETECTOR INSTALLATION 

CIRCUIT LAYOUT 

 

TERMINAL BLOCK CONNECTIONS 

 

 

Terminals 1 & 2 - Marked “ TAMPER ”  

If a Tamper function is required connect these 
terminals to a 24-hour normally closed protective 
zone in the control unit. If the front cover of the 
detector is opened, an immediate alarm signal will 
be sent to the control unit. 

 

 

 

 

Terminals 3 & 4 - Marked 

 R-PIR 

 

These are the output PIR relay contacts of the 
detector. Connect to a normally closed zone in the 
control panel. 

Terminal 5 - Marked “ EOL ” – 

End of line option. 

Terminals 6 & 7 - Marked 

 R-MIC 

 

These are the output MICROPHONE relay 
contacts of the detector. Connect to a normally 
closed zone in the control panel. 

Terminal 8 - Marked “ + ” (+12V) 

Connect to a positive Voltage output of 8.2 -16Vdc 
source (usually from the alar control unit) 

Terminal 9 - Marked “ - ” (gnd) 

Connect to the negative Voltage output or ground 
of the control panel. 

 

 
 

A. Wire 

access 

holes  

B.  Use for flat wall 

mounting 

C.  Corner mounting - 

use all 4 holes. 
Sharp left or right 
angle mounting - 
use 2 holes (top 
and bottom) 

D. For 

bracket 

mounting 

B

B

C

Unscrew the holding 

screw and open base

 

A

A

15m 

 

The Activ8 BG provides immunity up to 25Kg. 
For better immunity avoid installation in areas 
where pets can reach upwards.

 

 