background image

 

 

5897-35 RF DUAL TEC Motion Sensor Installation Instructions 

 

GENERAL INFORMATION 

The 5897-35 motion sensor combines dual technology motion 
detection with reliable 5800 wireless RF in one small package. 

Within the protected area, the passive infrared (PIR) detector senses 
changes in infrared energy (such as body heat emitted by an 
intruder), and turns on the microwave detector which senses the 
motion.   Both technologies must verify intrusion within a preset time 
interval, virtually eliminating false alarms.

 

To reduce current drain and prolong battery life, the microwave 
circuitry is dormant until the PIR detects a change in the infrared 
energy level. 

In addition, the 5897-35 sensor features a supervision circuit that 
monitors the microwave technology.  If a problem is detected, the 
sensor will go into alarm. 

The 5897-35 sensor is also equipped with both a Fresnel lens and 
multi-segmented PIR mirror.  This unique optical system provides 
dense PIR coverage from directly beneath the unit out to maximum 
range. 

FEATURES 

 Microwave/PIR technology 

  5800 Wireless technology 

  Dual element PIR 

  Unique PIR optics 

  Three minute hold off circuit 

  Single edge PIR triggering 

  Cover tamper switch 

  Lithium batteries included 

 Automatic walk-test mode 

 Simple installation 

  Optional barrier and pet- 

    alley lenses available 

 

MOUNTING LOCATION 

Select the best location in the room for both technologies.  Aim the 
sensor toward the interior of the room, away from windows, moving 
machinery, and heating/cooling sources.  Do NOT mount the detector 
near wire screens or large metal objects.  We recommend that you 
verify the RF reception prior to permanently mounting the sensor. 

Maximum range is obtained at a mounting height of 7'6" (2.3 m).   
Make sure the sensor has a clear line of sight to all areas you wish to 
protect. Infrared energy cannot penetrate solid objects.  If the PIR is 
blocked, the unit will not alarm. 

 

 
MOUNTING PROCEDURE 

Use the sensor's rear cover to mark the mounting holes.  To remove 
the sensor's rear cover, use a small-blade screwdriver to push up on 
the latch through the slot in the bottom of the front housing.  Gently 
pull the housings apart at the base first. 

The printed circuit board (PCB) is mounted in the front housing.  Do 
NOT remove the PCB. 

Securely mount the rear housing at the desired location.  When 
mounting the sensor on a wall, use the two knockout holes in the 

back of the rear housing.  When mounting the sensor in a corner, use 
the knockout holes on the beveled corners of the unit.  Remove the 
knock-outs, mark and drill the mounting holes, and mount the 
transmitter at the desired location.  Install the batteries and replace 
the cover; secure the cover with a #4 (5/16-in.) screw (supplied). 

INSTALLING THE BATTERIES 

The 5897-35 operates on four 3V lithium batteries.   Please note that 
the batteries must always be installed and replaced in a set of four!   
Acceptable battery types include Honeywell #466, Panasonic 
CR123A, Duracell DL-123A, or Sanyo CR123A.  Four batteries, 
shipped with the unit, must be installed prior to testing.  Proper 
orientation is shown in Figure 2.  After battery installation, the unit 
requires a 60-second warm-up prior to normal operation. 

NOTE:  To prevent excessive battery drain during setup and 
installation, you should remove the batteries whenever the cover is 
open and the unit is not being tested. 

SYSTEM TESTING 

Opening the front cover of the 5897-35 signals a tamper condition 
and automatically places the unit in the walk-test mode.  This also 
disables the three-minute hold off circuit.  The unit remains in this 
mode for a period of 8 minutes after the cover has been replaced.  
There are two walk-test LEDs located at the bottom of the unit behind 
the lens, one on each side.  These LEDs are only active while the unit 
is in the walk-test mode. 

Range

Adjust

Antenna

Test/Alarm

Jumper

ALARM

PIR

Test/Alarm

Jumper

Tamper

Switch(S1)

Figure 2

PCB Layout and Connections

Microwave Antenna

Walk-Test LEDs

 

A jumper at the bottom of the PCB, next to the Tamper Switch (S1), 
allows you to test the PIR section separately. Placing the jumper in 
the "PIR" position, as shown in Figure 2, allows you to walk-test the 
PIR without activating the microwave circuits. The range of the PIR 
detector is not adjustable. The PIR's field of view (range) is 
determined by the mounting height and the type of lens installed. 

WALK-TEST 

Walk-testing the 5897-35 motion sensor is a two-stage process. The 
first step is to walk-test the PIR. Walk across the protected area at the 
ranges to be covered. Two to four normal steps should make the 
LEDs light. Since the LEDs are connected in parallel, both LEDs will 
light at the same time. When there is no motion in the protected area, 
the LEDs should be off. The second stage is to adjust the range of 
microwave transmitter. For continued reliability, the sensor should be 
walk-tested at least once per year. 

RANGE ADJUSTMENT 

Returning the jumper to the ALARM position will reactivate the 
microwave circuits.  Remember that as long as the cover is open, the 
hold off circuit remains disabled. In order to adjust the microwave, the 
PIR must first see motion, which will activate the microwave circuitry. 

The microwave range potentiometer is located near the center of the 
PCB below the battery holder (refer to Figure 2).  With the PCB 
oriented in its correct mounting position and facing you, turning the 
potentiometer clockwise will INCREASE the range of the microwave. 

After determining the field of view for the PIR, set the microwave 
range potentiometer at MINIMUM by turning it counterclockwise as 
far as it will go.  (Use a small screwdriver to turn the range 
potentiometer.)  Then, with the test jumper in the ALARM position, 
walk-test the sensor, gradually increasing the sensitivity of the 
microwave until the desired range is obtained. 