5834-4 Series
Wireless Key Transmitter
I
NSTALLATION AND SETUP GUIDE
GENERAL INFORMATION
The 5834-4 key transmitter is a portable wireless transmitter for use only with wireless alarm systems that support 5800 Series receivers
(ex. VISTA series, LYNX PLUS, LYNX Touch).
•
Buttons are typically used for arming and disarming, but can be
programmed for any appropriate zone response.
•
A button must be pressed and held until the LED begins to flash
to activate a button function. This press and hold feature
minimizes the possibility of accidental transmissions.
•
The factory-installed replaceable lithium battery provides power
for up to five (5) years.
•
The 5834-4 transmitter provides up to eight (8) functions and has
an optional high security (encrypted) mode that sends rolling-
code encrypted messaging to the RF receiver.
High Security Mode Note:
If used in high security mode, must
be used with a receiver or control that supports high security
mode. i.e., 5881EN, 5883, 6150RF, or 6160RF receiver or
LYNXR Series control panel (Rev 13.1 or higher).
PROGRAMMING
For complete details on how to program the transmitter at the control panel, see the control unit's Installation Instructions. When
programming, note the following:
•
Each 5834-4 transmitter has two unique serial numbers assigned
during manufacture.
•
Each button on the unit also has a distinct "loop" number (refer to the
Loop Number diagram at right) that you must program into the control
panel during installation.
•
Assign each button to an individual zone and designate the Input Type
as "BR" (Button Type).
•
When prompted for the serial number, press and release the
appropriate button(s) twice, or, manually enter the serial number at the
keypad.
NOTE:
Serial #2 is one (1) digit higher than serial #1, which is printed
on the rear of the transmitter.
USING HIGH-SECURITY MODE
If used with LYNXR Series controls earlier than Revision
13.1, Standard Mode must be selected.
To use High Security mode, first select High Security mode, then activate
it. Activation syncs the keyfob with the security system.
1.
Select High Security mode:
Mode
Simultaneously hold down for 5 secs…
High-Security
A - C - D
(LED flashes Red when transmitting)
Standard
B - C - D
(LED flashes Green when transmitting)
2.
Activate High Security Mode:
Put the security system into Go/No Go
Mode, then press the appropriate set of buttons as follows:
Serial Number Simultaneously hold down until beeps sound…
1
A - B - C
buttons (system beeps twice to confirm)
2
A - B - D
buttons (system beeps twice to confirm)
Loop Numbers for the 5834-4 Keyfob Buttons
5834-008-V1
SERIAL #1
LOOP 4
SERIAL #1
LOOP 1
SERIAL #2
LOOP 1
SERIAL #2
LOOP 3
SERIAL #1
LOOP 3
SERIAL #2
LOOP 4
SERIAL #1
LOOP 2
SERIAL #1 FUNCTIONS ACTIVATE WHEN THE RESPECTIVE
BUTTON IS HELD DOWN UNTIL THE LED FLASHES.
SERIAL #2 FUNCTIONS ACTIVATE WHEN THE TWO RESPECTIVE
SERIAL #2 BUTTONS ARE PRESSED AT THE SAME TIME AND
HELD DOWN UNTIL THE LED FLASHES.
NOTE
1.
2.
SERIAL #2
LOOP 2
A
C
B
D
Using a Button:
To activate a programmed function,
press and hold the appropriate key(s) until the LED
begins to flash.
ASSIGNING A WIRELESS KEY TO A USER
•
On most control panels, if the wireless key is assigned to arm and disarm the system, you must assign it to a user in order for it to
operate. This is accomplished through User Code programming at the control panel. See the control panel’s Installation and Setup
Guide for specific instructions on programming User Codes.
The table below summarizes the procedures.
•
If programming arming and disarming functions on both serial numbers, each serial number must be assigned to a separate user.
On Vista 32/40/50/50P/100 and up
You must assign a user to the button in order for it to operate.
To assign a user number to the Arm/Disarm button:
1. Enter [4-digit User Code] + [8] + [User No.] + [new User Code].
2. Answer Yes or No to the “Open/Close Report ?” question.
3. Answer Yes to the “RF Button ?” question.
4. Enter the zone number assigned to the button.
5. Keypad display shows summary of user information.
6. Test all functions for proper operation.
On Vista-20P/15P/10P/Vista-21iP and variants
You must assign a user to the button in order for it to operate, and
must enter a sequence of keystrokes as described below.
NOTE:
There is a two-second timeout for keystroke commands on
Vista P series panels, therefore you must enter the keystrokes as
quickly as possible.
1. Enter [4-digit Master Code] + [8] + [User Number] +
[# 4] + [two digit zone number] assigned to the fob.
2. Test all functions for proper operation.