5834-2
Wireless Key Transmitter
INSTALLATION AND SETUP GUIDE
GENERAL INFORMATION
The 5834-2 key transmitter is a portable wireless transmitter for use only with wireless alarm systems that support 5800
Series receivers
(ex. VISTA series, LYNX PLUS, LYNX Touch).
•
Buttons are typically used for arming and disarming, but can be programmed for any appropriate zone response.
•
A button must be pressed and held until the LED begins to flash to activate a button function. This press and hold feature
minimizes the possibility of accidental transmissions.
•
The factory-installed replaceable lithium battery provides power for up to five (5) years.
•
The 5834-2 transmitter provides up to three (3) functions.
Using a Button:
To activate a programmed function, press and hold the appropriate key(s) until the LED begins to flash.
•
Serial #1 functions activate when the respective button is held down until the LED flashes.
•
Serial #2 function activates when the respective buttons are pressed at the same time and held down
until the LED flashes.
PROGRAMMING
For complete details on how to program the transmitter at
the control panel, see the control unit's Installation
Instructions. When programming, note the following:
•
Each 5834-2 transmitter has two unique serial numbers
assigned during manufacture.
•
Each button on the unit also has a distinct "loop"
number (refer to the Loop Numbers diagram) that you
must program into the control panel during installation.
•
Assign each button to an individual zone and designate
the Input Type as "BR" (Button Type).
•
When prompted for the serial number, press and
release the appropriate button twice, or, manually enter
the serial number at the keypad.
NOTE:
Serial #2 is one (1) digit higher than serial #1,
which is printed on the rear of the transmitter.
5834-011-V1
SERIAL #2
LOOP 1
SERIAL #1
LOOP 3
SERIAL #1
LOOP 2
Loop Numbers for the 5834-2 Keyfob Buttons
ASSIGNING A WIRELESS KEY TO A USER
•
On most control panels, if the wireless key is assigned to arm and disarm the system, you must assign it to a user in
order for it to operate. This is accomplished through User Code programming at the control panel. See the control
panel’s Installation and Setup Guide for specific instructions on programming User Codes.
The table below summarizes the procedures.
•
If programming arming and disarming functions on both serial numbers, each serial number must be assigned to a
separate user.
On Vista 32/40/50/50P/100 and up
You must assign a user to the button in order for it to operate.
To assign a user number to the Arm/Disarm button:
1. Enter [4-digit User Code] + [8] + [User No.] + [new User
Code].
2. Answer Yes or No to the “Open/Close Report ?” question.
3. Answer Yes to the “RF Button ?” question.
4. Enter the zone number assigned to the button.
5. Keypad display shows summary of user information.
6.
Test all functions for proper operation.
On Vista-20P/15P/10P, VISTA-21iP, and variants
You must assign a user to the button in order for it to
operate, and must enter a sequence of keystrokes as
described below.
NOTE:
There is a two-second timeout for keystroke
commands on Vista P series panels, therefore you must
enter the keystrokes as quickly as possible.
1. Enter [4-digit Master Code] + [8] + [User Number] +
[# 4] + [two digit zone number] assigned to the fob.
2. Test all functions for proper operation.