background image

 

 

N8331V3  5/04  Rev. A   

ADEMCO 5802MN2 

SUPERVISED MINIATURE TRANSMITTER 

INSTALLATION AND SETUP GUIDE 

The ADEMCO 5802MN is a wireless transmitter that may 
be worn on a belt or around the neck (belt clip and 
necklace supplied). Pressing both buttons on the 
transmitter at the same time sends a signal to the control 
receiver. The 5802MN2 is intended for use only with 
wireless alarm systems that support 5800 Series devices. 

The transmitter is supervised, i.e., it automatically sends a 
message to the control receiver that includes battery 
status information every 70-90 minutes.  

This transmitter can be programmed as any zone type 
response (e.g., Emergency Panic, Relay Action, etc.). 

BATTERY REPLACEMENT 

The 5802MN2 is powered by two long-life Lithium 
batteries that may be replaced when a low battery is 
eventually indicated by the control unit. 

NOTE: 

Although the 5802MN2 is water-resistant, please 

do not

 submerge. 

PROGRAMMING THE SERIAL NUMBER

 

The 5802MN2 has a unique identification code (serial 
number) permanently assigned during manufacture. 

You must “enroll” the transmitter’s serial number and loop 
number during system programming. The 5802MN2 may 
be defined as Input Type “RF” (supervised RF, 

do not 

take out of range) or “UR” (Unsupervised RF). Its loop 
number is “1.” See the control unit’s Installation 
Instructions for further details regarding programming. 
When installation is complete, verify operation from 
desired location(s). 

 

Specifications 

 

Unit Dimensions: 

 

2.75” (70mm) x 1.75” (45mm) x 0.5” (13mm) 

 

LED:

 

Lights when unit transmits. 

Battery:

  3V Duracell DL2430, or Newsum, Maxell, Panasonic, 

Renata, or Sanyo CR2430 

 

 

In UL installations: 3V Renata CR2430 only

 

STACK 2 BATTERIES
NEGATIVE SIDE DOWN

REMOVE INSIDE
FRONT COVER

5802MN2-001-V0

 

To access the batteries, pry open
the case front. In some cases,
you must first remove a small
Phillips-head screw from the case
back before prying open the case
front 

Note battery polarity: 
+ POS 

end must face up (visible

when installed).

 

 

REFER TO THE INSTALLATION INSTRUCTIONS FOR THE 
RECEIVER/CONTROL W ITH W HICH THIS DEVICE IS USED FOR 
WARRANTY INFORMATION AND FOR DETAILS REGARDING THE 
LIMITATIONS OF THE ENTIRE ALARM SYSTEM. 

 

FCC STATEMENT 

FCC ID: CFS8DL5802MN2 

CANADA: 1748102611 5 3 

This device complies with Part 15 of the FCC Rules. Operation is 
subject to the following two conditions: 
(1) This device may not cause harmful interference 
(2) This device must accept any interference received, including 

interference that may cause undesired operation

.

 

UL

 

US Listings: 

HOUSEHOLD BURGLARY WARNING SYSTEM 

CONTROL UNIT ACCESSORY 

UL

 

Canadian Listings: 

HOUSEHOLD 

BURGLARY W ARNING SYSTEM CONTROL UNIT ACCESSORY ALSO 
LISTED FOR USE AS A SIGNAL APPLIANCE, MISCELLANEOUS 
CERTIFIED FOR CANADA. 

ÊN8331V3QŠ

N8331V3  5/04  Rev. A  

 

 

 

 