5800MICRA transmitters

Dimensions Dowel Package

0.750" diameter (3/4")

Additional Info

Dowel Lid 0.850" diameter x 0.060" thick

Wire Antenna

8" x 1/8" flexible antenna

Fits Cavity Depth

0.330" depth (11/32")

Power Source

3.0V Lithium Coin Cell Battery CR1620

Temperature Range

10º to 120º F (-12º to 49º C)

Operating Gap

0.5"

Compatibility

Windows

All Vinyl Window Types, Wood Casement, Awning,

Double-Hung and Access

MOUNTING

(

See Figure 1

)

1. Mark the selected location for the transmitter on the frame of the window.
2. Mark the location for the magnet on the window sash, directly opposite the

transmitter location. Before drilling any holes, make sure that the successful

Go/No Go reception tests have been conducted as called for in the

5800MICRA transmitter section. (see page back.)

3. Drill a hole at the location marked for the transmitter (3/4" diameter, no

more than 11/32" deep).

4. Install the battery (observe polarity), then insert the transmitter into the

hole so that the cap is flush with the surface. Make sure the antenna goes

into the cavity as straight as possible.
DO NOT hammer the transmitter in place with hard blows. Press it into the

hole by hand.

The 5800MICRA uses a santaprene case that, once placed, is designed to

self-seal in the mounting hole. However, if desired, a thin bead of silicon

may be applied for additional moisture protection.

TOTHE INSTALLER

Regular maintenance and inspection (at least annually)

by the installer and frequent testing by the user are vital

to the continuous satisfactory operation of any alarm

system. The installer should assume the responsibility of

developing and offering a regular maintenance program

to the user, as well as acquainting the user with the proper

operation and limitations of the alarm system and its

component parts. Recommendations must be included for

a specific program of frequent testing (at least weekly) to

insure the system's operation at all times.
REFER TO THE lNSTALLATION INSTRUCTIONS FOR

THE RECEIVER / CONTROL WITH WHICH THIS DEVICE

IS USED FOR DETAILS REGARDING LIMITATIONS OF

THE ENTIRE ALARM SYSTEM.
FOR WARRANTY INFORMATION, PLEASE GO TO:

www.honeywell.com/security/hsc/resources/wa

BATTERY INSTALLATION & REPLACEMENT

Remove the transmitter from the window by inserting the flat blade of

a small screwdriver into the pry-slot on the cap end and twisting slightly

counter-clockwise. The transmitter must be removed from the window

completely in order to refit the transmitter properly back into the hole

once the internal battery has been replaced.
Using the flat blade of a small screwdriver in the pry-slot again, separate

the white cap from the base with a slight counter-clockwise twist.

Once open, slide the cap with the transmitter PC board assembly apart

from the base. Pull the antenna through the hole in the base just enough

to allow the battery to be replaced. Do not pull the antenna completely

out of the base.
Carefully remove the old battery from its battery holder on the bottom of the

PC board.

US Patent No. 6,737,969

800-07871 10/10 Rev. A

This device complies with FCC Rules part 15. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference that may be received, including interference that may
cause undesired operation.
The user shall not make any changes or modifications to the equipment unless authorized by the
Installation Instructions OR User Manual.
Unauthorized changes or modifications could void the  user's authority to operate the equipment.

FCC

Notice

Figure 2. SPECIFICATIONS

Before drilling any holes, make sure that successful

Go/No Go transmission reception tests have been conducted as called for in the

5800MICRA transmitter section.

BATTERY CAUTION: Risk of fire, explosion and burns.

Do not recharge, disassemble, heat above 212"F (100"C) or incinerate. Dispose

of used batteries promptly. Keep away from children.

Reed Switch / Magnet Positioning

Ensure that orientation of the switch and magnet is the same.

Reed Switch on

top side of PC board

(inside cap)

STEP 1

STEP 2

STEP 3 & 4

STEP 5 & 6

STEP 7

Figure 3. Battery Replacement

5800MICRA

Recessed Transmitter

Ê800-07871XŠ

2 Corporate Center Drive, Suite 100

P.O. Box 9040, Melville, NY 11747

Copyright © 2010 Honeywell International Inc.

5. Remove the adhesive backing on the magnet and place magnet at

marked location. Make sure magnet is placed in same orientation as

transmitter.

Magnet

Magnet

1.

2.

3.

Observe correct polarity (

see Figure 3, Step 3 & 4

) and insert the fresh battery

into the battery holder (positive polarity indicator is shown on the battery holder).
Slide the cap with the PC board assembly back into its base by gently pulling on

the antenna, easing the transmitter cap into place.
Snap the transmitter cap back onto the base, locking it into place.
Placing the antenna into the cavity first, reinsert the transmitter into its original

mounting hole in the window. Be sure to install the transmitter in the

same orientation as the accompanying sash-mounted magnet.

4.

5.

6.
7.