background image

 5800-OD Wireless Outdoor Motion Sensor –  Installation Instructions 

 

 

GENERAL INFORMATION

 

The Honeywell 5800-OD Wireless Outdoor Motion Sensor 
(referred to as the 5800-OD) combines the convenience of wireless 
technology with a full featured outdoor PIR motion sensor.  The 
major features are highlighted below: 

ƒ

 

Immunity to bright light 
disturbances from headlights, 
sunlight, and other bright 
light sources. 

ƒ

 

Very low current draw. 

ƒ

 

Discriminates both large and 
small animals to reduce false 
alarms. 

ƒ

 

Selectable detector 
range and angle. 

ƒ

 

Battery saving circuit allows 
for a 5 or 120 second period of 
inactivity before being 
reactivated. 

ƒ

 

Tamper detection. 

 

SPECIFICATIONS 

Detection Method 

Passive Infrared 

Initial Warm Up 

~ 2 minutes 

Mounting Height 

0.8 - 1.2m (2.7 - 4ft) wall or pole 

 

 

Range 

Adjustable up to 12m (40ft) 

Pattern 

90

°

 pattern consisting of 13 zones.  This 

pattern can be adjusted in 15

°

 incre-

ments from center up to 45

°

.   

Sensitivity 

2.0

°

 C at 0.6m/s (3.6

°

 F at 2.0ft/s) 

Detection Speed 

0.3 - 1.5m/s (1 - 5ft/s) 

Operating Voltage 

6 VDC (uses 4 lithium 1.5VDC AA cells) 

Current 

3mA max (during walk test) 10uA 
(standby) 

Battery Saving Timer 

Adjustable 120sec or 5sec 

Alarm Period 

~ 2.5 seconds 

LED Indicator 

Enabled during a walk test. 
Disabled for normal operation. 

Weatherproof 

IP54 compliance 

Operating Temperature 

– 20 to + 50 

°

 C (– 4 to +122

°

 F) 

Humidity 

95% Max 

Accessories (included) 

Pole mounting kit, screw kit, detection 
masking strips.  

 
 

 
 

INSTALLATION (refer to the Component Identification Diagram on page 5)

 

 1 

  

Select the Mounting Position

 

‰

 

Avoid strong sunlight into the sensor's field.

 

‰

 

Avoid moving or swaying trees and bushes.

 

‰

 

Orient the detector 
so that intrusion 
passes across the 
detection field, not 
into the sensor. 

 

 

 

 

‰

 

Allow 110mm (4.4") 
above the sensor to 
enable  opening the 
cover. 

 

‰

 

Choose an installation 
height of 0.8m to 1.2m 
(2.7 to 4ft).  

 

‰

 

Ensure the sensor can be 
mounted on a perpendicular 
wall or pole that would make 
its detection pattern parallel 
to the ground. 

 

Parallel

 

 2 

  

Prepare the Sensor for Mounting

 

1.

 

Loosen the Captive Lock 
Screw and remove the 
Cover. 

 

2.

 

Remove the four (4) screws fastening the Detector 
to the Back Box.

 

 

 

3.

 

Remove Detector from the Back Box. 

 

 

 3 

 

 

Install / Replace the Battery

 

IMPORTANT: 

ƒ

 

Use only lithium batteries. 

ƒ

 

Use four (4) lithium 1.5VDC AA cells.  (Energizer L91 or 
equivalent.) 

ƒ

 

Observe polarity. 

ƒ

 

Mark the date of replacement on the batteries.

 

1.

 

If necessary, loosen the 
Captive Lock Screw and lift 
Cover off.  Then, remove 4 
screws that secure the 
Detector to the Back Box. 

2.

 

Observe the proper polarity 
and replace the batteries.  

Ensure positive side of 
battery is pointing away from 
the springs.

 

3.

 

For reference, mark the date of 
replacement on the batteries. 

 

 
 

PLEASE GO TO PAGE 6 FOR FCC / IC STATEMENTS

Содержание 5800-OD

Страница 1: ...therproof IP54 compliance Operating Temperature 20 to 50 C 4 to 122 F Humidity 95 Max Accessories included Pole mounting kit screw kit detection masking strips INSTALLATION refer to the Component Identification Diagram on page 5 1 Select the Mounting Position Avoid strong sunlight into the sensor s field Avoid moving or swaying trees and bushes Orient the detector so that intrusion passes across t...

Страница 2: ...Cover with the Captive Lock Screw 5 Perform Settings Adjustments SET THE DETECTION LENGTH Note The length of the lower detection area determines the detection length The upper detection area stays parallel to the ground at all times The lower detection area can be adjusted as shown below by the switch position Detection length is therefore limited by the length of the lower detection area since bo...

Страница 3: ...ingers o 45 Adjustable o 2 Hold the sensor and turn it to the desired direction Each click represents 15 of change Adjust to desired direction IF NECESSARY CONFIGURE DETECTION MASKING 1 Spread the Cover and gently press on the Lens to remove the Lens Holder 2 Separate the Lens from the Cover Cover Lens Area Masking Plate Lens Holder 3 Identify the segments on the Lens to be masked 4 Then apply the...

Страница 4: ...ple traffic pass close to the detection area adjust the detection area 1 5 to 2 0m 5 to 7ft shorter to reduce false detections This also allows for changes due to environmental thermal conditions If the detection length is adjusted to position A 12m 40ft the detection area may increase when there is a big temperature difference between the moving object and the background If this causes a problem ...

Страница 5: ...light source Perform a Settings Adjustments procedure Lower detection area is too long Set Detection Length to a shorter range A heat source in the area may be causing an abrupt temperature change Move or remove the heat source Mask the area pointing to the source of heat or shorten the Detection Length COMPONENT IDENTIFICATION Mounting Screws T4 x 20 Detector Sensor Do not touch Cover LED Indicat...

Страница 6: ...d fail at any time We have cited some of the most common reasons that a Passive Infrared Motion Detector can fail to catch intrusion However this does not imply that these are the only reasons and therefore it is recommended that weekly testing of this type of unit in conjunction with weekly testing of the entire alarm system be performed to ensure that the detectors are working properly Installin...