Query Commands
Several special characters can be used to query the device about its settings.
^
What is the default value for the setting(s).
?
What is the device’s current value for the setting(s).
*
What is the range of possible values for the setting(s). (The de-
vice’s response uses a dash (
-
) to indicate a continuous range of
values. A pipe (
|
) separates items in a list of non-continuous val-
ues.)
Tag Field Usage
When a query is used in place of a Tag field, the query applies to the
entire set
of commands available for the particular storage table indicated by the Storage
field of the command. In this case, the SubTag and Data fields should not be
used because they are ignored by the device.
SubTag Field Usage
When a query is used in place of a SubTag field, the query applies only to the
subset of commands available that match the Tag field. In this case, the Data
field should not be used because it is ignored by the device.
Data Field Usage
When a query is used in place of the Data field, the query applies only to the
specific command identified by the Tag and SubTag fields.
Concatenation of Multiple Commands
Multiple commands can be issued within one Prefix/Storage sequence. Only
the Tag, SubTag, and Data fields must be repeated for each command in the
sequence. If additional commands are to be applied to the same Tag, then the
new command sequence is separated with a comma (
,
) and only the SubTag
and Data fields of the additional command are issued. If the additional command
requires a different Tag field, the command is separated from previous
commands by a semicolon (
;
).
Responses
The device responds to serial commands with one of three responses:
ACK
Indicates a good command which has been processed.
ENQ
Indicates an invalid Tag or SubTag command.
NAK
Indicates the command was good, but the Data field entry was out of the
allowable range for this Tag and SubTag combination, e.g., an entry for a
minimum message length of 100 when the field will only accept 2
characters.
When responding, the device echoes back the command sequence with the
status character inserted directly before each of the punctuation marks (the
period, exclamation point, comma, or semicolon) in the command.
Содержание 5010
Страница 1: ...5X10 5X80 5010 80 5110 80 5310 80 User s Guide ...
Страница 54: ...4 26 ...
Страница 62: ...5 8 ...
Страница 68: ...6 6 ...
Страница 104: ...7 36 RSS Limited Default All RSS Limited Settings RSS Limited RSS Expanded Default All RSS Expanded Settings On Off ...
Страница 124: ...7 56 ...
Страница 152: ...10 6 ...
Страница 178: ...11 26 ...
Страница 182: ...12 4 ...
Страница 190: ...A 6 ...
Страница 191: ......
Страница 195: ...OCR Programming Chart a e d g c h t l Discard Save r ...
Страница 196: ...Programming Chart A C B F E D 1 0 2 3 ...
Страница 198: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com 5X10 80 UG Rev C 4 12 ...
Страница 199: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Honeywell 5310 ...