Honeywell 4AV15F Скачать руководство пользователя страница 1

Installation Instructions for the

ISSUE 2

4AV Series Vane Sensors

PK 87605

MICRO SWITCH Sensing and Control

PERSONAL INJURY

DO NOT USE these products as safety or
emergency stop devices or in any other application
where failure of the product could result in personal
injury.
Failure to comply with these instructions could
result in death or serious injury.

GENERAL INFORMATION

4AV Hall effect vane sensors include a Hall effect

sensor and a magnet in a common package. They
are operated by passing a ferrous vane through the
gap between the magnet and the sensor.

With no vane in the gap, the output is Operated

(conducting). With the vane in the gap, the output is
Released (non-conducting). The vane actuator is
annealed low carbon cold rolled steel, type AISI
1018 or lower in carbon. Minimum recommended
vane dimensions are required to ensure operating
characteristics will be met.

ELECTRICAL CHARACTERISTICS

Catalog

Listing

Termination

Lead

Length

Supply

Voltage

All Listings

Supply

Current

All Listings

Output

Voltage

All listings

Output

Sink Current

All listings

4AV15F

24 AWG Wire

5.50 

±

 0.25

4AV16F

24 AWG Wire

7.45 

±

 0.25

4AV17F

24 AWG Wire

13.15 

±

 0.50

18.5 mA Max

@ -40 

°

C

15.25 mA typical

0.4 V Max

@125 

°

C

0.1 typical

4AV18F

24 AWG Wire

18.15 

±

 0.50

4AV19F

24 AWG Wire

22.00 

±

 0.50

4AV20F

.015 X .025 PCB

0.140

4AV20F-T1*

.025 X .025

Connector

AMP Terminal

Block 103323-4

 4AV20F-T2**

.025 X .025

Connector

Molex Terminal

Block 22-05-3041

4.5 VDC

through

26.5 VDC

11.75 mA

@25 

°

C

typical

0.075 V

@25 

°

C typical

40 mA Max

Dual output

sink currents

are summed

to reach total.

*Will mate with AMP Connector Housing 87499-8, not supplied
**Will mate with Molex Connector Housing 2695/6471, not supplied

VANE DIMENSIONS (mm/in)

Thickness

Min.
Window

Min.
Tooth

Min. Tooth
Depth

1,0/0.4

10,2/.40

10,2/.40

9,27/.365

1,6/.06

10,2/.40

6,3/.25

9,27/.365

Содержание 4AV15F

Страница 1: ...ane dimensions are required to ensure operating characteristics will be met ELECTRICAL CHARACTERISTICS Catalog Listing Termination Lead Length Supply Voltage All Listings Supply Current All Listings Output Voltage All listings Output Sink Current All listings 4AV15F 24 AWG Wire 5 50 0 25 4AV16F 24 AWG Wire 7 45 0 25 4AV17F 24 AWG Wire 13 15 0 50 18 5 mA Max 40 C 15 25 mA typical 0 4 V Max 125 C 0 ...

Страница 2: ...the 4AV are adjusted to produce a 100 010 dimension between the Operate point on one side of the package to the Release point on the other side The actuator can be designed to produce a specific pulse width for timing or sequencing operations MOUNTING DIMENSIONS for reference only CAUTION PRODUCT DAMAGE Do not exceed electrical specifications Do not mis wire the output connection Do not reverse su...

Страница 3: ...his will remove all moisture from the assembly which must be done before electrical testing or application Machine Cleaning Detergent London Chemical Company Loncoterge 444 NRT6 or equivalent Equipment Dee Electric Aqueous Cleaner or equivalent The following is reccommended 1 Wash Section 55 C 130 F maximum water temperature 5 to 10 maximum solution soft water low pressure nozzles 60 psi on top sp...

Страница 4: ...oing is Buyer s sole remedy and is in lieu of all other warranties expressed or implied including those of merchantability and fitness for a particular purpose Specifications may change without notice The information we supply is believed to be accurate and reliable as of this printing However we assume no responsibility for its use While we provide application assistance personally through our li...

Отзывы: